42-739-002 -
Pickering Interfaces Ltd.
The 40-739-002 (PXI) and 42-739-002 (PXIe) are dual 16-channel 2-pole multiplexers designed specifically for physical layer multiplexing or demultiplexing differential signals that conform to the MIL-STD-1553 specification. The module can be supplied as a single or dual 16-channel 2-pole multiplexer with each signal pair having a controlled 78 Ohm differential impedance.
-
42-739-006 -
Pickering Interfaces Ltd.
The 40-739-006 (PXI) and 42-739-006 (PXIe) are dual 4-channel 2-pole multiplexers designed specifically for physical layer multiplexing or demultiplexing differential signals that conform to the MIL-STD-1553 specification. The module can be supplied as a single or dual 16-channel 2-pole multiplexer with each signal pair having a controlled 78 Ohm differential impedance.
-
781785-01 -
NI
The NI-5191 is a differential, active voltage probe that offers 800 MHz of input bandwidth with a 10:1 attenuation ratio. You can use it with oscilloscopes that provide 50 Ω input impedance. You can power the probe using a Type-N barrel power connector from a USB port or using a 9 V alkaline battery.
-
784255-01 -
NI
1 GHz, ±8 V, 10X Attenuation, Single-Ended Active Oscilloscope Probe - The SA1000X is single-ended, active voltage probe that is used for many different high-speed measurement applications. The probe is powered by an included auxiliary power supply that is internationally compatible and certified. You can use it with oscilloscopes that provide 50 Ω input impedance.
-
42-739-003 -
Pickering Interfaces Ltd.
The 40-739-003 (PXI) and 42-739-003 (PXIe) are single 8-channel 2-pole multiplexers designed specifically for physical layer multiplexing or demultiplexing differential signals that conform to the MIL-STD-1553 specification. The module can be supplied as a single or dual 16-channel 2-pole multiplexer with each signal pair having a controlled 78 Ohm differential impedance.
-
42-739-004 -
Pickering Interfaces Ltd.
The 40-739-004 (PXI) and 42-739-004 (PXIe) are dual 8-channel 2-pole multiplexers designed specifically for physical layer multiplexing or demultiplexing differential signals that conform to the MIL-STD-1553 specification. The module can be supplied as a single or dual 16-channel 2-pole multiplexer with each signal pair having a controlled 78 Ohm differential impedance.
-
42-739-005 -
Pickering Interfaces Ltd.
The 40-739-005 (PXI) and 42-739-005 (PXIe) are single 4-channel 2-pole multiplexers designed specifically for physical layer multiplexing or demultiplexing differential signals that conform to the MIL-STD-1553 specification. The module can be supplied as a single or dual 16-channel 2-pole multiplexer with each signal pair having a controlled 78 Ohm differential impedance.
-
40-739-005 -
Pickering Interfaces Ltd.
The 40-739-005 (PXI) and 42-739-005 (PXIe) are single 4-channel 2-pole multiplexers designed specifically for physical layer multiplexing or demultiplexing differential signals that conform to the MIL-STD-1553 specification. The module can be supplied as a single or dual 16-channel 2-pole multiplexer with each signal pair having a controlled 78 Ohm differential impedance.
-
40-739-004 -
Pickering Interfaces Ltd.
The 40-739-004 (PXI) and 42-739-004 (PXIe) are dual 8-channel 2-pole multiplexers designed specifically for physical layer multiplexing or demultiplexing differential signals that conform to the MIL-STD-1553 specification. The module can be supplied as a single or dual 16-channel 2-pole multiplexer with each signal pair having a controlled 78 Ohm differential impedance.
-
MT7553 Series -
Maury Microwave Corporation
Noise Parameters are the non-50Ω extensions of Noise Figure, and are an important modeling and model validation tool to understand how a device-undertest’s performance changes as a function of source impedance. Noise Parameter measurements are typically performedusing a Vector Network Analyzer (VNA) to measure the S-Parameters of the DUT, and a Noise Analyzer (either Noise Figure Analyzer NFA or Spectrum Analyzer SA) to measure the noise power of the DUT. Noise parameters are calculated from a combination of knownsource impedances, S-parameters and noise powers.
-
PRB-HP-9258 -
TEAM SOLUTIONS, INC.
The Oscilloscope Probe 1:100 - HP-9258 is a low-input capacitance high voltage 1:100 oscilloscope probe with a bandwidth of 250 MHz designed and calibrated for use on scopes having an input impedance of 1 MOhm shunted by 20 pF. However, it may be compensated for use with oscilloscopes having an input capacitance of 10 - 35 pF.
-
cBP-3208/3206/3204[R] -
ADLINK Technology Inc.
*PICMG 2.0 CompactPCI Specification Rev. 2.1 compliant*Numbers of slot: 8/6/4 slots (incl. system slot)*Width: cBP-3208R: 36HP (9-slot) cBP-3206R: 28HP (7-slot) cBP-3204R: 20HP (5-slot)*Right one slot is system slot and others are peripheral slots*10-layer PCB for accurate impedance control and electr
-
40-739-001 -
Pickering Interfaces Ltd.
The 40-739-001 (PXI) and 42-739-001 (PXIe) modules are single 16-channel 2-pole multiplexers designed specifically for physical layer multiplexing or demultiplexing differential signals that conform to the MIL-STD-1553 specification. These modules can be supplied as a single or dual 16-channel 2-pole multiplexer with each signal pair having a controlled 78 Ohm differential impedance.
-
11636B -
Keysight Technologies
The Keysight 11636B is a dc to 26.5 GHz power divider for direct power dividing applications. The excellent impedance match of all three ports improves fault location measurements by reducing re-reflections. The Keysight 11636B power divider/combiner is recommended when making wideband comparison measurements with the Keysight 8757 scalar vector network analyzer.
-
11636A -
Keysight Technologies
The Keysight 11636A is a dc to 18 GHz power divider for direct power dividing applications. The excellent impedance match of all three ports improves fault location measurements by reducing re-reflections. The Keysight 11636A power divider/combiner is recommended when making wideband comparison measurements with a Keysight 8757 scalar vector network analyzer.