S911T -
Copper Mountain Technologies
*S911T Calibration Kit, * Frequency Range: up to 9 GHz, * Impedance: 50 Ohm, * Connector Type: 3.5 mm female.
-
-
Precision Acoustics LTD
Rexolite or perspex wedges incorporate a pyramidal scattering surface with an impedance matched acoustic absorber to minimise internal reflections within the wedge.
-
Isotek
IsoTek’s unique Direct Coupled Design system offers extremely low impedance high current clean power for the hardest of loads.
-
Texas Co.
They are normally designated X1 and X10, although 1X and 10X are sometimes seen. The designation refers to the factor by which the impedance of the scope itelf is multiplied by the probe.The X1 probes are suitable for many low frequency applications. They offer the same input impedance of the oscilloscope which is normally 1 MΩ. However for applications where better accuracy is needed and as frequencies start to rise, other test probes are needed.
-
7600 -
IET Labs
The 7600 Plus LCR Meter performs precision impedance measurements over a frequency range of 10 Hz to 2 MHz. The LCR Meter can measure 14 different impedance parameters with 0.05% accuracy, meeting today's requirements for component and material testing. The ease of use and user-friendly menu programming makes the 7600 Plus ideal for applications in product development, incoming inspections, or production line testing.
-
Barth Electronics, Inc
Barth High Voltage Pulse Attenuators are matched impedance coaxial attenuators for use primarily in pulsed 50 ohm systems, or where occasional transients would damage ordinary units. The attenuator design closely matches the impedance around each resistor, to that resistor. These attenuators feature an input impedance very close to 50 ohms, with characteristics as good or better than most microwave attenuators. These units are ideal for use in nuclear and high energy experiments. Extensive testing during manufacturing insures very high reliability for single-shot experiments. A voltage coefficient of the resistive film of less than .0001 %/V allows low voltage calibration of most systems.
-
NF Corp.
A/D converted input signals undergo discrete Fourier transform (DFT) to calculate complex impedance values and obtain parameters and characteristics specific to the DUT, such as its capacitance, inductance and quality factor. Original NF algorithms are also applied to allow equivalent circuits made up of R, L and C along with the constants for those circuits to be estimated from the complex impedance spectrum obtained by sweeping the frequencies.
-
NF Corp.
An LCR meter measures impedance (inductance, capacitance and resistance) at spot frequencies.It is used for testing components and materials in R&D applications and in componet manufacturing.
-
783630-01 -
NI
The SP500C, or Multi-Contact Isoprobe IV - 100:1, is a standard passive probe with fixed 100x attenuation for oscilloscopes that provide 1 MΩ input impedance.
-
783629-01 -
NI
The SP500X, or Multi-Contact Isoprobe IV - 10:1, is a standard passive probe with fixed 10x attenuation for oscilloscopes that provide 1 MΩ input impedance.
-
VI Control Systems Ltd.
All channels provide for voltage division ahead of transient suppression before going into the S&H ICs. Channels that are sampled and held use a common sample and hold pulse that samples while high and holds while low. Jumpers on each S&H chip allow buffering of analog signals where sample and holds are not required. An advantage to the buffers is that it provides a high input impedance for high impedance voltage dividers.
-
DP-30K -
PINTEK Electronics
*30KVp-p, High Voltage Model .*Input Impedance 81.6MΩ//1PF *x200, x2000 Attenuator, Easy to Convert.*Separating Design(Standard No.114205)*Convenient & Durable.
-
PRS Series -
IET Labs
A broad range of programmable resistance decade boxes for applications requiring a programmable impedance unit, controlled manually and by a computer via an IEEE-488, RS-232 or Ethernet interface.
-
PL-50Pro -
PINTEK Electronics