FM1 -
NG Systems Ltd
This unit will allow fine adjustment of overall focus of a CCTV camera, especially useful whenever a monitor is not available. It operates by analysing the detail in the centre of the picture and provides a 10 bar LED readout, displaying maximum output when the camera image is in sharpest focus. An input impedance switch provides selection between terminated (75Ω) and unterminated (high impedance) input.
-
PL-10N -
PINTEK Electronics
*MODEL:PL-10N*IMPEDANCE:1.111MΩ*ACCURACY:±0.5%*FREQUENCY B.W.:DC~50MHz*WORKING POWER:MAX. 1Watt*INPUT VOLTAGE:MAX.250VDC or 200V rms AC*DIMENSION:48mm(L)xΦ16mm(D)*WEIGHT:25g*APPLICATION: Matching the impedance of the Scope probe with the DMM. with this converter, the user can use the oscilloscope to watch the wave from and measure the precise reading from the DMM.
-
-
Model 7V -
CONTROLWEIGH
Impedance: 350 ohms nominal. Output Ranges:Fixed rotary switch: 0 to 3 mv/v in 6 steps of .5 mv/v .
-
-
PA-V Series -
Partikel-Analytik-Messgeräte GmbH
The PA-V series are ultralow noise and distortion, broadband and low impedance amplifiers. The frequency range can be adjusted according to customer requirements.
-
STME-VM -
Statclean Technology (S) Pte Ltd
This is a High Input Impedance Voltmeter with 70 Gigohm input impedance. Capable of measuring up to DC voltage up to +/-5.5kV with 1.0V resolution over a range of himidity and temperature, the meter measures with better than 1% accuracy without loading the power source. Its compact size and light weight body allows applications in laboratory and field work when powered by battery.
-
Keysight Technologies
Keysight offers a wide range of benchtop LCR meters to meet your impedance measurement needs in the field of R&D, production, quality assurance, or incoming inspection. In addition to the high measurement performance and versatile functions of Keysight benchtop LCR meter, you will find the LCR accessories best suited for your measurement among a full lineup of Keysight impedance measurements.
-
PROMAX Electronica
The instrument is equipped, in addition to the 20 Hz-160 MHz input, a second input for measurement up to 2.4 GHz with an impedance of 50 Ohms.
-
Model 7 -
CONTROLWEIGH
Impedance: 350 ohms nominal. Output Ranges: Fixed rotary switch. 0 to 3 mv/v in 6 steps of .5 mv/v .
-
Model 0V -
CONTROLWEIGH
SPECIFICATIONS: Impedance: 700 ohms nominal. Output Ranges: 10 turn vernier 0 - 3mV/V. Excitation: 20v ac/dc max,
-
Model TS-16 -
CONTROLWEIGH
Impedance: 350 ohms nominal. Output Ranges: Fixed rotary switch: 0 to 3 mv/v in 15 steps of .2 mv/v
-
Z5411 -
Copper Mountain Technologies
*Z5411 Calibration Kit, * Frequency Range: up to 54 GHz, * Impedance: 50 Ohm, * Connector Type: 2.4 mm female.
-
T4311 -
Copper Mountain Technologies
*T4311 Calibration Kit, * Frequency Range: up to 40 GHz, * Impedance: 50 Ohm, * Connector type: 2.92 mm female.
-
S2611 -
Copper Mountain Technologies
*S2611 Calibration Kit, * Frequency Range: up to 26.5 GHz, * Impedance: 50 Ohm, * Connector type: 3.5 mm female.