Pulse Mask
determines if a pulse signal fits within it's desired frequency band.
-
Product
12 Pulse Diode Bridge Rectifiers Inside Fiberglass Plenums, P/N 5872C4-2
-
- 12 Pulse Diode Bridge Rectifier, P/N 5872C4-2- Each diode is rated for 60 Amps, 1800 Volts peak- Dimensions: 50″L x 40″W x 20″H approximately- Four 10″ fans are used for coolingFour 10″ fans will force cool from the bottom of the Plenum. 12 diode assemblies (each diode consists of nine diodes in series are integrated together inside the Plenum). The output is rated for 3000 VDC, 80 Amps.
-
Product
MASK MVM-SEM® E3600 Series
E3650
-
Amid the progress of multiple-exposure technology, and the development of finer-pitch and more complicated circuits, as well as increases in the number of masks and the number of measurement points on each mask, the size of wiring patterns formed on photomasks needs to be measured and evaluated stably with high precision. Advantest’s E3600 series meets the needs of state-of-the-art devices with high measurement repeatability and stable throughput.
-
Product
30 A, 10 MHz Current Probe - AC/DC, 30 A rms, 50 A Peak Pulse, 3 Meter Cable
CP030-3M
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
IP Pulse
-
IP Compatible card with 4 programmable pulse generators. TTL or RS422 / RS485 compatible outputs. Programmable pulse - nS to seconds. Programmable count or free
-
Product
50 µs Pulse Medium Current Source/Measure Unit (MCSMU)
B1514A
Source Measure Unit
The 50 s Pulse Medium Current SMU is an SMU designed for faster pulsed IV measurement. It enables a pulsed measurement down to 50 s pulse width, a 10 times or more narrow pulsed measurement than provided by a comparable conventional SMU. In addition, the instrument offers a wider range and versatility, up to 30 V / 1A, with voltage/current programmability. It is useful to characterize high to medium power devices on the new materials such as SiC and GaN, and organic devices, and the MCSMU expands your choices of pulsed IV measurement.
-
Product
12-Watt Pulsed FAYb Fiber Laser
LP-V Series
-
Panasonic Industrial Devices Sales Company of America
The LP-V series is a 12-watt, pulsed fiber laser.Characteristics:- Very high resolution- Fine marking area- Small air cooled head
-
Product
Bounded Output Mask
-
The bounded output mask provides a means of ensuring that measurements of TI according to IEC 62359 can satisfy the requirement of only determining the ultrasonic output through an area of 1 cm x 1 cm.
-
Product
Pulse Heat Unit (Hot Bar Bonder)
-
*This method is most suitable for reliable soldering and thermo-compression because heating and cooling are done applying the pressure force*Good repeatability of heating temperature and time requires no skilled workers*Partial heating in short time allows to reduce thermal damages*For implement of Pb free
-
Product
High Voltage Pulse Generators
-
Berkeley Nucleonics Corporation
Designed to provide precision control over the output waveform to enable process optimization for research and industrial customers.
-
Product
Pulse Adapter
CV5P350
-
Frothingham Electronics Corporation
The CV5 P350 station is the first mid power pulser in a series of exponential pulse generators that can be connected to an FEC200E tester. This gives you all the versatility of the proven FEC200 with the addition of high power exponential pulses. For exponential pulses up to the 10/1000, the CV5 P350 can produce up to 5KW, 500A, or 350V whichever is most limiting. It can also test all of the usual FEC200 tests in the same test program.
-
Product
PCI Pulse Position Data Communication Board
MS 1708
-
*Bus Interface - PCI Bus*Micro controller Based Design*Shared Memory for Communication*8 Channels RS422 / Modified RS422*PPD (Pulse Position Data) Bus Interface*Driver interface for Windows2000/XP/VISTA and LINUX OS*Independent Intelligent Devices for RS422 and PPT Communication
-
Product
120 A High Voltage 50 Ω Pulse Generator
TLP-12010C
-
High Power Pulse Instruments GmbH
- High pulse output current up to 120 A (short circuit)- Ultra-fast 50 Ω high voltage pulse output with typical rise time 100 ps (0 A to 40 A) and 300 ps in high-current mode (0 A to 120 A)- Wafer, package and system level TLP, VF-TLP and HMM testing- Up to 180 kW peak output power into 50 Ω load- Built-in HMM pulse up to ±32 kV in 50 Ω-configuration- High speed 50 Ω trigger output for oscilloscopes (synchronous to high voltage pulse output)- 6 USB programmable pulse rise times: 100 ps to 50 ns (custom selectable)- 8 (optional 9) programmable pulse widths: 0.5 ns (optional), 1 ns to 100 ns (0 A to 40 A), 1 built-in pulse width: 100 ns (>40 A)- The optional pulse width extender TLP-3011C enables pulse width up to 1.6 µs in 68 GPIB programmable steps (0 A to 40 A)- Optional external pulse width extensions from 5 ns to 500 ns (>40 A to 120 A)using the external pulse width extender TLP-12012A6- Built-in pulse reflection suppression- Fast measurement time, typically less than 0.2 s per pulse including one-point DC measurement between pulses- Efficient sofware for system control and waveform data management- The sofware can control automatic probers for fast measurements of complete wafers- Combines TLP-12010A and TLP-4010C into one system- Can be operated together with TLP-12012A6 and TLP-3011C pulse width extenders- Integrated interlock safety shut-down- Industrial isolated and EMI/ESD protected USB control interface
-
Product
Modular Pulse Processing Electronics
-
CAEN provides a complete and ever increasing set of instrumentation, from Preamplifiers to Data Acquisition to Triggering Electronics and Logic Functions. Most of the instrumentation is available in the most popular standard form factors and bus protocols, such as VME, NIM, CAMAC and Desktop.The Desktop is the stand alone form factor of the CAEN products. It provides the same performances of the other form factors and take the advantage of an easier and portable use, requiring no crates.
-
Product
50A, 50 MHz CURRENT PROBE, BNC, AC/DC, 50A rms, 75A Peak Pulse
T3CP50-50
-
50A, 50 MHz CURRENT PROBE, BNC, AC/DC, 50A rms, 75A Peak Pulse.
-
Product
Pulse
-
*MODBUS Master RS485 / RS232*Up to 10 slaves or 15 registers per slave*Monitoring and supply of power to the sensor*Local and remote configuration
-
Product
30 Amps, 50 MHz BW Current Probe - AC/DC , 50 Amp Peak Pulse
CP030
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
120 GHz Frequency Extender, Pulsed DC Bias
N5295AX52
Frequency Extender
The N5295AX52 is a compact and broadband frequency extender with built-in pulsed bias-tee and provides 10 MHz to 120 GHz single-sweep measurements with N5292A test set controller systemized with a PNA/PNA-X B vector network analyzer.
-
Product
Group Pulse Generator
-
Beijing KeHuan Century EMC Technology Co,.LTD
Group Pulse Generator.
-
Product
Masks Bacterial Filtration Efficiency Tester
-
Sataton Instruments Technology CO., Ltd
Face Masks bacterial filtration efficiency BFE tester is to determine the bacterial filtration efficiency (BFE) of medical face mask materials by employing a ratio of the upstream bacterial challenge to downstream residual concentration of the tested medical face mask materials. The tester provides certain flow rate of bacterial aerosol. The operator can measure the number of colony forming units passing through the medical face mask material, which is clamped between a six-stage Anderson cascade impactor and an aerosol chamber, expressed as a percentage of the number of colony forming units present in the challenge aerosol.
-
Product
PXIe-4135, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 10 fA Precision System PXI Source Measure Unit
783762-01
Source Measure Unit
PXIe, ±200 V, ±1 A DC, ±3 A Pulsed, Up to 40 W DC, 10 fA Precision System PXI Source Measure Unit - The PXIe-4135 is a high-precision, system source measure unit (SMU). It features 4-quadrant operation and sources up to 40 W of DC power and can pulse up to 500 W. Analog-to-digital converter technology and native triaxial connectors help you perform high-precision measurements with a current resolution of 10 fA or high-speed acquisitions up to 1.8 MS/s. The module also can maximize stability and measurement accuracy with SourceAdapt technology, which you can use to tune the transient response to match the characteristics of any load. The PXIe-4135 is ideal for a broad range of applications including manufacturing test, board-level test, and lab characterization with devices such as ICs, power management ICs (PMICs), and RFICs and discrete devices including LEDs and optical transceivers.
-
Product
NanoLattice Pitch Standard for Mask Handling Tools (NLSM)
-
The NanoLattice™ (NLSM) 100 nm pitch standard utilizes gratings with near perfect periodicity to calibrate magnification and scan linearity of CD-SEM and Atomic Force Microscopes (AFM). Make the grade, with the only pitch standard of its kind available below the 130 nm node.
-
Product
4 Channel 24.5~ 29.0 Gb/s Pulse Pattern Generator and Error Detector
CA9808
-
The UC INSTRUEMNTS CA9808 4 Channel 24.5 ~ 29.0 Gb/s (100Gb/s) Pulse Pattern Generator and Error Detector is a high performance, flexible and cost effective four channel Pulse Pattern Generator and Error Detector that can operate from 24.5 Gb/s to 29 Gb/s each Channel. 4 channel 29.0 Gb/s make it total up to over more than 100 Gb/s testing capacity. It is also a standalone Bit Error Rate test solution that incorporates an internal full rate clock synthesizer.
-
Product
Panel-mount Type pH Meter (Four-Wire Transmission, Pulse Proportional Control)
HP-480PL
-
HP-480PL industrial pH meter is a pH meter with a pulse proportional control function, which can drive a pulse pump directly.It connects pH sensor and measures pH and temperature in the sample water.As the HP-480PL has a high injection resolution per pulse, it can be used to control a pulse pump as part of a system for processing involving fine control of pH values, for example controlling the pH values of microscopic or small samples.
-
Product
Pulse energy and power measuring instrument
LEM 2410
-
A touch panel and function keys make this device comfortable and easy to handle. The preamplifiers integrated into the device and the choice of sensor sensitivity allow a wide range of sensor heads to be used. The large graphic display offers space for a variety of display and analysis choices. The digital display can be used for determining the energy, frequency and average power.
-
Product
State, Event & Pulse Data Loggers
-
These data loggers can record rates from pulse output transducers, on/off or open close state changes or events.
-
Product
Split type Pulse Current Sensor
PCT-06
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Through hole type pulse current sensor.*Pulse current sensor for power demand meter.
-
Product
Frequency-Resolved Optical Gating Pulse Analyzer
IQFROG
Analyzer
The IQFROG measures pulse intensity and phase in both spectral and temporal domains, yielding a complete pulse characterization. With its long delay arm and high resolution spectrometer, it measures chirped pulses up to 50 ps wide, or up to 10 ps wide if the pulse is transform limited. The IQFROG is available in 1.0 and 1.5 micron wavelengths.
-
Product
Xenon Long Pulse Solar Simulator Three Target Sizes
-
Complies with IEC60904 Class A solar simulation standards.Up to 100ms of effective irradiated time is achieved. Through our proprietary filter technology, spectral concordance conforms to IEC / JIS Class A standards.Three systems provide a wide selection to meet your panel size, floor space, and performance requirements.
-
Product
12 Channels 1.0 ~ 17.0 Gb/s (200Gbps) Pulse Pattern Generator and Error Detector
CA9806-12
-
The UC INSTRUEMNTS CA9806-12 is a highp erformance, flexible 12 channels Pulse Pattern Generator and Error Detector that can operate from 1.0 to 17.0 Gb/s (200 G). It is combined with three sets CA9806 4 CH 1.0 to 17.0 Gbps Pulse Pattern Generator and Error Detector that incorporates an external one by 4 rate clock synthesizer. Its small size allows it to be placed close to the device under test, it can also be placed further away using the TX driver pre and post emphasis controls features to compensate for cable and interconnect losses. It also has a non destructive, integrated eye outline capture feature along with a quick eye height and width measurement capability. Build-in 8.5 ~ 15 Gb/s eye diagram testing function.
-
Product
Avionics Radio and Pulse Tester
T-RX
-
Streamline your avionics radio testing process with the CCX Technologies T-RX Avionics Radio and Pulse Tester. The T-RX is an all-in-one avionics tester that conducts 100+ tests on over 16 systems with only 1 device!