Filter Results By:

Products

Applications

Manufacturers

Showing results: 1456 - 1470 of 1719 items found.

  • Battery Impedance Meter

    Alpha Lab, Inc.

    Operation is fast and simple. Just press the spring-loaded probes onto the two poles of the battery. After 1.5 seconds, the unit beeps (indicating good contact) and displays the battery voltage and either the number of siemens or milliohms, depending on the knob setting. The display continues to show these numbers after the probes are removed; it resets only when the probes are pressed onto the next battery. The impedance and voltage of any battery between 1.2 and 60 volts can be read. Because of the wide range of voltages, even single low-voltage cells, such as NiMH, can be measured. The manufacturers of some batteries specify impedance in milliohms while other specify in siemens (one divided by the resistance in ohms). This meter will display both types of impedance for any given battery. Accuracy is +/- 2% of the value.

  • Power Amplifiers for Radio Amateurs

    Kuhne electronic GmbH

    From classic equipment for simple QSOs to high performance modules for contests, EME-operations and satellite radio: Our products provide absolute top performance. When choosing their equipment many radio amateurs and club-stations don't compromise and trust in the proven quality of Kuhne electronic amplifiers. Numerous contest victories, records and first contacts with a country were and are achieved with Kuhne products. Our amplifiers are remarkable for high gain and high linearity. LD-MOSFET and GaAs-FET-systems are the state-of-the-art technology in the amateur sector and enable the perfect use for all analog and digital modes (e.g. SSB, CW, WSJT, ATV, DATV). Small mechanical measurements and milled aluminum cases enable high temperature stability and tower mounting. Don't compromise and get technology from Kuhne electronic!

  • Milliohm Meter

    16502 - Chroma Systems Solutions, Inc.

    Basic accuracy : 0.05%Pulsed test current output mode is used to reduce thermal EMFs affection on milliohm measurementDC test current output mode is used to fasten measurement speed for inductive DUTDry-circuit test current output mode (limited Max. 20mV) is used to measure such contact resistances where the maximum open-circuit voltage must be limited to 50mVTemperature correction (TC function) regardless of material or temperatureUseful temperature conversion function for motor/ coil evaluation4 channels R scan with balance check function for fan motor (combined with A165017 option)0.001mΩ~1.9999MΩ wide measurement range with 4½ digits resolutionStandard RS-232 interfaceOptional GPIB & Handler interfaceBin-sorting functionComparator and pass/fail alarming beeper functionLarge LCD display (240 x 64 dot-matrix)Friendly user interface

  • SSMA Connectors

    Pasternack Enterprises, Inc.

    Pasternack SSMA connector category includes 52 part numbers, most are RoHS and REACH compliant. SSMA connector series in this category will terminate to coax, PCB (printed circuit board) or terminal. Pasternack SSMA connectors are built to precise microwave and RF industry specifications. Connectors in SSMA series are manufactured in male or female gender with 50 Ohm impedance. SSMA connector items are available in straight or right angle versions, as well as, bulkhead, 2 hole panel, 4 hole panel or mountless options. These SSMA connector designs include crimp/solder, solder, solder (without contact) or solder/solder attachment methods. Like the other over 40,000 RF, microwave and millimeter wave products from Pasternack, this SSMA connector series is in-stock. Not just in stock, but these connectors will ship the same day as they are purchased.

  • Programmable Step Attenuator, DC to 4 GHz, 0 to 11 dB, 1 dB steps

    8494G - Keysight Technologies

    The Keysight 8494G dc to 4 GHz programmable step attenuator offers exceptional repeatability and reliability. Attenuation is provided in 1 dB steps from 0 to 11 dB. Precision gold-plated leaf springs ensure long-life (over 5 million cycles) and very high attenuator repeatability (typically 0.01 dB). To improve measurement accuracy, NIST traceable data (SWR and attenuation) is available as Option UK6. A maximum switching time of 20 ms (including contact settling) speeds automatic testing. Custom step attenuator/switch combinations are possible. The Keysight 11716A/B/C interconnect kits provide quick connection of Keysight 8494/5/6/7 1 dB and 10 dB step attenuators in series for greater dynamic range with 1 dB steps.

  • PXI Ultra High Density 64x2 2-Pole Matrix

    40-533B-032 - Pickering Interfaces Ltd.

    The 40-533B ultra high density matrix module is configured as 64x4 or 64x2 and is available in a choice of 1-pole and 2-pole reed relay formats. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance.

  • PXI Ultra High Density 64x2 1-Pole Matrix

    40-533B-031 - Pickering Interfaces Ltd.

    The 40-533B ultra high density matrix module is configured as 64x4 or 64x2 and is available in a choice of 1-pole and 2-pole reed relay formats. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance.

  • PXI 6U PXI High Density Matrix, 132x8 1-Pole

    45-541-001 - Pickering Interfaces Ltd.

    This 6U PXI Reed Relay Matrix Module is an ultra high-density reed relay matrix available in 132x8 format with 1- pole switching. Typical applications include signal routing in Functional ATE and data acquisition systems. The matrix is constructed using high reliability Sputtered Ruthenium Reed Relays, offering >10e9 operations to give maximum switching confidence with long life and stable contact resistance.

  • Custom Environmental Test Chambers

    Tenney Environmental

    Does your environmental testing conditions have special requirements, or are you unsure of the right product for you? Tenney and Lunaire Environmental offer custom environmental test chambers - including custom climate chambers and custom vacuum chambers. The experienced Tenney and Lunaire team can provide customizations to their climatic chamber models based on client needs. Contact the sales team today to discuss you specific testing requirements.

  • Voltage Protection

    Mors Smitt Group

    Are solid state voltage sensing relays with electromechanical output contacts built in a fully draw out case format. Designed for application on AC & DC voltage systems, these relays are ideally suited to monitor power supply voltage levels wherever high accuracy and reliable, maintenance free operation is essential. All power to operate the relays is derived from the sensed input voltage therefore an auxiliary supply is not required.

  • Ultra High Density 64x4 1-Pole PXI Matrix

    40-533B-021 - Pickering Interfaces Ltd.

    The 40-533B ultra high density matrix module is configured as 64x4 or 64x2 and is available in a choice of 1-pole and 2-pole reed relay formats. Typical applications include signal routing in Functional ATE and data acquisition systems. These PXI matrix modules are constructed using high reliability sputtered Ruthenium reed relays, offering >109operations to give maximum switching confidence with long life and stable contact resistance.

  • Capacitors - Beam Lead

    Macom Technology Solutions Holdings Inc.

    MACOM’s MMI-9000 and 9100 Series Chip Capacitors feature high stand-off voltage and low dielectric loss leveraging nitride/oxide dielectric layers. Gold bonding surfaces, top and bottom provide ease of bonding and minimum contact resistance. MACOMs beam lead capacitors have high insulation resistance, low dissipation factor, and low temperature coefficient, which are features that produce devices with excellent long-term stability.

  • Data Logger

    Lead Connection - Hanwell

    A single channel data logger for temperature measurement with LCD display and fitted internal temperature sensor. This reliable transmitter is used with our renowned Hanwell Pro temperature humidity monitoring system for 24/7 data and instant alarm notifications. Contact us today for your free quotation and signal strength test (we can prove ours to be unrivalled) or to discuss your specific temperature monitoring requirements and application.

  • Terminal Level 2 Test Tool

    EVAL - FIME SAS

    The EVAL Test Suite is a range of test libraries designed for compliance testing of EMV debit/credit payment terminal applications. It is the most complete test suite for terminal and smart card manufacturers, laboratories, banks, services providers and application software developers, thanks to its comprehensive list of qualified test libraries: EMV Contact, Entry Point Book B, MasterCard PayPass, Visa ADVT and American Express Expresspay.

  • Automotive RF Design Verfication Test System

    LXinstruments GmbH

    The system is used for design verification of RF assemblies. By using similar measurement technology and test software as in the production testers, parts of the test procedures developed in development can be reused in production. The DUTs are tested in RF-tight shield boxes and contacted via original plugs. The shield boxes are connected via N-connectors and other typical laboratory contacts. This allows test setups to be easily modified and individual signal paths to be separated.

Get Help