Filter Results By:

Products

Applications

Manufacturers

Similar Topics: Fixtures

Fixtures

orient and afix UUT.

See Also: Board Test Fixtures


Showing results: 631 - 645 of 690 items found.

  • DataComm

    SCHILLER AUTOMATION GmbH & Co. KG

    With ever-growing performance, accuracy, and precision required by 112G/800G PAM4 solutions, Wilder has designed a robust HCB and MCB fixtures to support OSFP-XD, QSFP-DD, OSFP and SFP-DD compliance testing. In addition, CMIS_GUI Software provides: Displays of many of the settings and Controls in the Module including Lane States, Module Power States and Optical Power. Alarms and Warnings for Module Temp and Vcc and Optical Power Controls for Module Power, Margins, and read access to Descriptors and Data Path Configuration. Direct Read/Write access to the I2C and CMIS Memory Map as well Scripts that directly access the CMIS Memory Map Registers.

  • Pod with Four Test Access Ports for 5v or 3.3V TTL Thresholds

    JT 2137 - JTAG Technologies Inc.

    The JT 2137 pod remains a popular choice for DataBlaster controller installations that require a compact signal conditioning pod embedded within a test fixture. The JT 2137 features four test access ports which together may be set for 5v or 3.3V TTL thresholds, although additional plug-in adapters are available that allow alternative thresholds to be set on a TAP by TAP basis (contact your local sales office for details). The 20-way 0.1″ IDC TAP headers comply with the standard JTAG Technologies 20-way pin-out and provide the additional flash programming controls Read/Busy and AutoWrite.

  • SHC68-C68-D4, Shielded Single-Ended Cable, Low Leakage, 1m

    152870-01 - NI

    68-Pin, Male VHDCI to 68-Pin, Male VHDCI, 50 Ω, Shielded Digital Cable - The SHC68-C68-D4 Digital Cable connects NI 6535/6/7, 654x, 655x, and 657x digital instruments with other NI accessories like the CB-2162 Connector Block or SMB-2163 Terminal Block. You can also use it with certain Digital I/O Adapter Modules for FlexRIO, Digitizer Adapter Modules for FlexRIO, Signal Generator Adapter Modules for FlexRIO, and high-speed serial instruments. It is flexible and easily fits around custom test fixtures and other equipment. It is a shielded, 50 Ω cable and is offered in different lengths.

  • C68-C68-D4 Unshielded Cable, 2X68-Position VHDCI Offset, 1 m

    195949-01 - NI

    68-Pin, Male VHDCI to 68-Pin, Male VHDCI, 50 Ω, Unshielded Digital Cable - The C68-C68-D4 Digital Cable connects NI 6535/6/7, 654x, 655x, and 657x digital instruments with other NI accessories like the CB-2162 Connector Block or SMB-2163 Terminal Block. You can also use it with certain Digital I/O Adapter Modules for FlexRIO, Digitizer Adapter Modules for FlexRIO, Signal Generator Adapter Modules for FlexRIO, and high-speed serial instruments. It is flexible and easily fits around custom test fixtures and other equipment. It is an unshielded, 50 Ω cable.

  • Finite Element Analysis

    Arcadia Test

    This useful tool will minimize induced stress on the board under test. The 3-D software will account for all components populated on the board, and probe force and push rod locations on the fixture. It uses this information to simulate the actual test to determine which area of the board is enduring too much stress and then provide suggestions to correct the situation. A damaged board could cost upwards of thousands of dollars and lost time. Including Board stress analysis in your test strategy is an excellent way to insure that your new test comes up fast, and without any stress related board damage.

  • Computer Networking Solutions

    Circuit Check, Inc.

    Today’s world has a never ending appetite for data. Everywhere you look there are connected devices that provide and consume that data at an astonishing rate, and the demand increases every day. Our computer and networking customers are constantly pushing the edges of technology to deliver data faster and more reliably than ever. They use the newest electronics available to keep our data flowing – data that is critical to the operation of the world’s infrastructure. As cutting edge technologies are developed, these faster more advanced capabilities require the most sophisticated testing available. Circuit Check is constantly evolving our test fixtures and systems to meet this industry’s most advancedrequirements.

  • Military & Aerospace Solutions

    Circuit Check, Inc.

    Military and aerospace electronics spans a vast array of complex applications, including communications, vehicle control, radar, electronic warfare and countless others. Although the applications are widely varied, there are similarities in the requirements as well. Typically these electronic systems, whether COTS (Commercial Off- the-Shelf) or custom developed for the application, share similar requirements for ruggedness, reliability, and precision. Our customers don’t have room for error, mission critical hardware test systems must perform as designed. Circuit Check provides military and aerospace testing solutions for ITA’s, Self-Test Fixtures and Automated Test Systems that meet the stringent needs of this marketplace.

  • Passive Component LCR Meter

    Extech LCR200 - Extech Instruments Corporation

    The LCR200 is a passive component LCR meter. Discover the tremendous value with a range of features that help this meter provide the precise measurements you need. See simultaneous 20,000/2,000 count display of the primary parameter on the high contrast backlit display. You can set Hi/Lo limits using absolute values or percentages. Open and Short Zero removes unwanted stray impedances from the measurement. Use the built-in test fixture or external test leads (included). The LCR200 has an Auto Power Off function that can also be disabled and a low battery indicator to alert you when to replace the batteries. Complete with test leads and 9V battery.

  • PC Based Test Setup for LED Driver of LED

    SCR ELEKTRONIKS

    The tests are Performed as Prescribed in IS the Panel Carries out high voltage, open circuit and performance tests, one by one and provides indication of the Test results as PASS or FAIL lamp for high voltage test. It is very useful and handy in line testing on Mass production line as well as type Testing. Special fixture can be provided for the specific product. This avoids the connections & disconnections of the product for different tests. The total time for entire testing is less than 80 seconds. Micro controller based sequential timer maintains the sequence of operation and displays the test status. The entire system is housed in sturdy M.S cabinet with powder coating.

  • SHC68-C68-D4 Shielded Single-Ended Cable, 0.55 m

    781013-01 - NI

    68-Pin, Male VHDCI to 68-Pin, Male VHDCI, 50 Ω, 0.55m, Shielded Digital Cable - The SHC68-C68-D4 Digital Cable connects NI 6535/6/7, 654x, 655x, and 657x digital instruments with other NI accessories like the CB-2162 Connector Block or SMB-2163 Terminal Block. You can also use it with certain Digital I/O Adapter Modules for FlexRIO, Digitizer Adapter Modules for FlexRIO, Signal Generator Adapter Modules for FlexRIO, and high-speed serial instruments. It is flexible and easily fits around custom test fixtures and other equipment. It is a shielded, 50 Ω cable and is offered in different lengths.

  • Spectrum Analysis, Up To 70 GHz

    S930907B - Keysight Technologies

    The S930907B spectrum analysis (SA) adds high-performance microwave spectrum analysis to the N522xB/N524xB PNA family up to 70 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • Enhanced Time-Domain Analysis With TDR

    S95011B - Keysight Technologies

    This application enables the analyzer to perform enhanced time domain analysis for high-speed data applications. All functionality of the S95010B are included (TDR/TDT mode). In addition, the S95011B enables more detailed measurements and evaluations, such as eye-diagram / mask modes, without adding PLTS software. Jitter and emphasis / equalization capabilities enable simulation of real-world signals and environment. The S95011B covers up to 53 GHz bandwidth. Full calibration is available and the automatic deskew ensures easy removal of fixture and probe effects. To get the best accuracy, mechanical calibration kits or ECal with DC option (i.e., N469xD or N4433D with Option 0DC) are recommended.

  • Spectrum Analysis, Up To 26.5 GHz

    S930902B - Keysight Technologies

    The S930902B spectrum analysis adds high-performance microwave spectrum analysis to the PNA family up to 26.5 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Simultaneous spectrum measurements can be done using up to five test and reference receivers. This multi-channel SA can be used with the internal swept-signal generators for efficient measurements of spurious signals emanating from mixers and frequency converters. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • PXI 10A Fault Insertion Switch 6-chan 2-bus

    40-192-012 - Pickering Interfaces Ltd.

    This PXI fault insertion switch uses solid state switching elements and is capable of switching current up to 10A. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test: Open-Circuit. Short-Circuit between UUT connections. Short-Circuit to external signals. Through relays on each channel enable signals to the UUT to be set open-circuit. Fault Insertion Buses allow any channel to be shorted to any other channel and also enable any channel to be connected to an external signal such as Power, Ignition or Ground to simulate fault conditions. The module is supplied with 2 fault buses.

  • PXIe-5650, 1.3 GHz RF Signal Generator

    781215-01 - NI

    The PXIe‑5650 features continuous-wave generation capabilities with FM, 2‑FSK, or OOK modulation. It uses direct digital synthesis (DDS) for high-resolution frequency hopping or phase-continuous sweeping for fixture and device characterization applications. The PXIe‑5650 is ideal for clocking nonstandard sample rates, such as WCDMA signals at baseband or intermediate frequency (IF). With these versatile signal generators, you can perform analog and digital modulation through the onboard DDS circuit, which gives you frequency modulation and frequency-shift keying for applications such as bit error rate test, antenna testing, or even keyless entry. You can also perform amplitude modulation using on-off keying.

Get Help