Filter Results By:

Products

Applications

Manufacturers

Noise

a signal's fluctuation other than that desired.

See Also: Pink Noise, White Noise, RF Noise, Distortion, NVH


Showing results: 1711 - 1725 of 2118 items found.

  • 200/400 MHz Data Converter Test Solution

    ATX7006A - APPLICOS

    The ATX7006A is a fully integrated solution for testing ADCs, DACs and other Analog functions. It combines very high accuracy, low noise and fast sampling with an exceptional ease of use. Traditionally data converters are tested using a whole stack of bench instruments, filters, switch matrices and user made software. Many engineering hours are needed to get reliable results. The ATX7006A is a single instrument for all your data converter testing and test methods.

  • NI-9252, ±10 V, 50 kS/s/ch, 24-Bit, 8-Channel C Series Voltage Input Module

    786783-01 - NI

    ±10 V, 50 kS/s/ch, 24-Bit, 8-Channel C Series Voltage Input Module - The NI-9252 is an 8-channel analog input module for CompactDAQ and CompactRIO systems. Each channel provides a ±10 V measurement range and 24 bits of resolution at a 50 kS/s sample rate. The NI-9252 features a number of programmable hardware filters. By choosing the specific Butterworth and comb filters for your application, you can significantly reduce the noise in your system.

  • NI-9252 , ±10 V, 50 kS/s/ch, 24-Bit, 8-Channel C Series Voltage Input Module

    786782-01 - NI

    ±10 V, 50 kS/s/ch, 24-Bit, 8-Channel C Series Voltage Input Module - The NI-9252 is an 8-channel analog input module for CompactDAQ and CompactRIO systems. Each channel provides a ±10 V measurement range and 24 bits of resolution at a 50 kS/s sample rate. The NI-9252 features a … number of programmable hardware filters. By choosing the specific Butterworth and comb filters for your application, you can significantly reduce the noise in your system.

  • RF Training Kit And Lab Sheets

    Y1800A - Keysight Technologies

    The RF transceiver kit consists of a transmitter unit and a receiver unit in superheterodyne architecture. The transceiver units are made up of various RF building-block modules such as filter, low noise amplifier, power amplifier, mixer and oscillator. The RF transceiver kit is controlled by a Windows-based Control Panel software via USB. A Measurement Automation Program is provided to demonstrate automated characterization and test of RF circuits. A signal generator and a spectrum analyzer are required to run this program.

  • ATE System Power Supplies

    N8700 Series - Keysight Technologies

    The Keysight N8700 Series ATE system power supply delivers high current with low noise in a compact two unit package. Airflow moves front to back, so no additional space is required above or below the power supply in your automated test equipment (ATE) rack. This series of programmable power supplies sources up to 3300 or 5200 W. Get output voltages from 8 to 600 V and 5.5 to 400 A.

  • Cross-Spectrum CPB (Constant Percentage Bandwidth) Analysis

    ZETLAB Company

    CPB analysis is used for fractional octave spectral processing of signals coming from the input channels of FFT spectrum analyzers (in real time or recorded time realization view mode), as well as for viewing various spectral characteristics of signals. CPB analysis is used for separating signals into basic constituents in the frequency area in 1/3-, 1/12-, 1/24-octave spectral bands. The software is used for noise spectral analysis within the scope of acoustic and vibrational measurements.

  • RF Spectrum Analyzer

    FSA-100 - ShinewayTech

    ShinewayTech® FSA-100 series 6GHz spectrum analyzer are widely used in 2G/3G/4G/5G etc. FSA-100 series have the industry's rare high receiver sensitivity performance with a minimum display average noise level of -165dBm/Hz. Power measurement dynamic range up to 100dB, maximum RF input power exceeds 27dBm. FSA-100 series are equipped with a 7" ultra-large capacitive touch screen (resolution 1024*600). Excellent user experience.

  • PCI Bus Analog Output Board, 4 Isolated Outputs, 14 Bit

    APCI-3501-4 - TEAM SOLUTIONS, INC.

    4 analog output channels Optical isolation 500 V Settling time 30 µs typ. 14-bit resolution (13 bit for 0-10 V) Output voltage: ±10 V, 0-10 V (switchable through software) Output voltage after reset: 0 V Each output channel has its own ground line (without optical isolation from the others) Driver capacity: 5 mA/500 pF Short-circuit protection, EMI filters Noise neutralization of the PC supply Creeping distance: 3.2 mm acc. to DIN VDE 0411-100 Watchdog for resetting the analog output channels (4 different time units: µs, ms, s, min) or as 12-bit timer (with interrupt possibility), when the watchdog function is not necessary2 digital input channels, 24 V, isolated 2 digital output channels, 24 V, isolated Noise immunity Test level: ESD: 4 kV Fields: 10 V/m Burst: 4 kV Cond. radio interferences: 10 V

  • RF Components

    Copper Mountain Technologies

    Using a Vector Network Analyzer (VNA) for RF component testing for design and manufacturing is based on how the component performs. The analyzer is used in multiple ways from design to manufacturing to tuning, field monitoring and maintenance of antennas, filters, mixers, amplifiers, circulators, isolators, and other RF components. Key considerations component designers should pay attention to when finding an analyzer that fits their needs is a great dynamic range, low trace noise, and fast measurement speed.

  • Acoustic Calibrators

    Castle Group Ltd.

    When you're ready to take noise measurements, it's strongly recommended that you perform a field calibration using an Acoustic Calibrator. You should calibrate your sound meter before you start to measure, and then once you've finished you should perform a reference check against the calibrator and make note of any drift that has occured. You can find out more about performing Field Calibrators by reading this post and watching a short video.

  • Iifrasound Monitoring System

    INFRASONITUS - BioAge s.r.l.

    The infrasonic signal, acquired by a suitable microphone, is filtered by an active low-pass filter of the fifth order with a cut-off frequency at 20 Hz, with low noise, then it is sampled and acquired by a 16-bit ADC with a speed of 50 samples. / sec. The amplification factor can be set to 0.1 / 0.5 / 1/10.The infrasonic monitoring system includes a complete diagnostic functionality that performs an exhaustive functional test without the use of other tools: this function is extremely useful when the system is installed on the volcano at high altitudes.

  • Shunt Voltage References

    Analog Devices Inc.

    Analog Devices offers a broad line of shunt precision voltage references that combine excellent accuracy and temperature stability with low noise and small packages. These devices operate in a manner that is functionally equivalent to a Zener diode. The bias current must be set higher than the sum of the maximum quiescent current of the voltage reference and the maximum expected load current. Since shunt voltage references are typically biased with a resistor, the voltage reference can operate on a wide range of input voltages.

  • Phase Locked Loop (PLL) Synthesizer & Translation Loop

    Analog Devices Inc.

    ADI’s industry leading phase locked loop (PLL) synthesizer family features a variety of high performance, low jitter clock generation and distribution devices. The extensive, ever growing family includes over 100 products, optimized for high data rate, low jitter clocking applications. The portfolio features PLLs, PLL/VCOs, and distribution chips, designed for clocking applications where synchronization, clock distribution, and phase noise performance are all vitally important.

  • Digital Audio Snake System

    OmniSnake - En Technology

    The OmniSnake consists of a Stage Box that converts microphone/line-level analog inputs to a multiplexed digital signal, and a companion Base Unit that de-multiplexes to provide individual outputs. Digitizing the analog audio at the source eliminates the potential for ground loops, noise interference and crosstalk. Each Stage Box has 8 inputs, and two Stage Boxes can be linked together via coax to form a combined 16 channels, which is carried over coaxial cable to the Base Unit.

  • Tire Rolling Resistance Test System

    Ono Sokki

    This system measures the rolling resistance of each tire accurately. In addition to the simultaneous measurement of tire loss resistance and rolling resistance coefficient for each drive by mode operation (JC08, WLTC), coasting test, constant acceleration/deceleration test and transient mode test are able to be performed. Furthermore, measurement of driving noise/ vibration of the tire, effect of the tire loss due to the temperature change can be verified by adding options.Conforming the JIS D 4234: 2009 and ISO 28580: 2009.

Get Help