Showing results: 1291 - 1305 of 2129 items found.
-
McLAREN Applied Technologies
DHE (Differential Hall Effect) sensors give an output when subjected to a changing magnetic field. The field is set up by a magnet inside the sensor body and changes when ferromagnetic teeth are passed beneath the sensor (no magnets are required in the target). To improve noise resistance, the sensor has two Hall effect elements and only responds to changes in magnetic field strength corresponding to tooth passing frequencies above 15Hz. As each tooth passes the sensor, the digital state of the output changes
-
Analog Devices Inc.
Analog Devices GaAs MMIC-based wideband distributed amplifiers cover the dc to 65 GHz frequency range in various ultrawide bandwidths. Our design catalog includes low noise amplifiers, power amplifiers, and driver amplifier designs to meet your needs in applications such as electronic warfare, radar, electronic countermeasures, optical applications, and instrumentation. To meet diverse design requirements, some of our LNAs also offer internal-self biasing that requires only a signal drain voltage to operate.
-
Teledyne DALSA
As a leader in CMOS innovation, Teledyne DALSA developed the Xineos to deliver three times more sensitivity and five times more signal-to-noise performance than other standard technologies at equal X-ray dose conditions. CMOS image detectors offer numerous advantages including the ability to record smaller image details with higher resolutions – allowing for the diagnostics of medical anomalies at earlier stages, and significantly increasing the probability of early intervention, patient recovery, and reduced treatment costs.
-
Teledyne DALSA
Teledyne DALSA's leadership in CMOS innovation lets our Xineos scanning products deliver three times more sensitivity and five times more signal-to-noise performance than other standard technologies at equal X-ray dose conditions. CMOS image detectors offer numerous advantages including the ability to record smaller image details with higher resolutions – allowing for the diagnostics of medical anomalies at earlier stages, and significantly increasing the probability of early intervention, patient recovery, and reduced treatment costs.
-
Model 5791 -
Pentek, Inc.
- Simultaneous synthesis of up to five different clocks- Eight SMC clock outputs- Typical phase noise: -105 dBc/Hz @ 1 kHz offset- All clocks are phase-locked to input reference signal- Input reference frequency of 5 to 100 MHz- Four programmable VCXOs with 32-bit tuning resolution- Output clocks of 1, 2, 4, 8, or 16 submultiples of VCXO base frequencies- Output clock frequencies between 50 and 700 MHz- Control and status over the VPX backplane
-
Model 5891 -
Pentek, Inc.
- Simultaneous synthesis of up to 10 different clocks- 16 SMC clock outputs- Typical phase noise: -105 dBc/Hz @ 1 kHz offset- All clocks are phase-locked to input reference signal- Input reference frequency of 5 to 100 MHz- Eight programmable VCXOs with 32-bit tuning resolution- Output clocks of 1, 2, 4, 8, or 16 submultiples of VCXO base frequencies- Output clock frequencies between 50 and 700 MHz- Control and status over the VPX backplane
-
Communications & Power Industries
The CPI TMD high-voltage power supplies offer many features desirable for modern radar and electronic warfare applications: high efficiency, ultra-low voltage ripple (low noise), high inverter frequencies, ultra-low pulse-to-pulse jitter, low throughput delay and high power density. The units are lightweight and compact with excellent thermal management, and the high-voltage sections are encapsulated with an oil-free, silicone-based compound. This provides excellent protection in harsh environments while also enabling easy maintenance.
-
SC-20 -
Eddy Co.
The SC-20 system controller is capable of executing an entire coating run with the push of a single button. The backlit LCD display provides an easy way to monitor the coating and system status while running. The SC-20 can communicate not only with other Eddy process controllers, but with most OEM controllers as well. This makes it a perfect candidate for system upgrades as well as new builds. Noise protected circuitry coupled with continuous logic software ensures the process will be controlled and monitored throughout the whole process.
-
40-870A-003 -
Pickering Interfaces Ltd.
The 40-870A-003 (PXI) and 42-870A-003 (PXIe) are 50Ω RF switches with 3 separate SPDT relays in a single slot. They have low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The switch banks been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz. The injection of noise and unwanted signals into the signal paths of the 40/42-870A has been minimized by careful attention to the mechanical and electrical design.
-
40-870A-103 -
Pickering Interfaces Ltd.
The 40-870A-103 (PXI) and 42-870A-103 (PXIe) are 50Ω RF switches with 3 separate SPDT relays in a single slot. They have low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The switch banks been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz. The injection of noise and unwanted signals into the signal paths of the 40/42-870A has been minimized by careful attention to the mechanical and electrical design.
-
Idex Health and Science
Our comprehensive line of Semrock optical filters helps your design attain the best signal-to-noise ratios. Steep spectral edges maximize useable bandwidth, and high transmission or reflection captures the brightest images with best-in-class Flatness. Deep and extended blocking are optimized for your application, minimizing background and crosstalk while reducing cost. Select from the extensive catalog or go with a custom filter to your exact specifications, and remain confident of uncompromising quality, reliability, and reproducible results.
-
Hinds Instruments, Inc.
Hinds Instruments Birefringence Measurement technology has been adopted by industry leaders world wide to measure birefringence and characterize stress birefringence in materials with unsurpassed accuracy, resolution and repeatability. Capable of measuring optical retardation at 0.001nm resolution with noise floors as low as 0.005nm, these systems are robust, dynamic and scalable to fit the demanding requirements of your application. We provide measurement systems across the light spectrum (DUV, VIS and NIR) and are able to measure virtually all optical materials.
-
Analog Devices Inc.
Analog Devices multiplexed channel precision A/D converters include one ADC and span 8-bit to 24-bit resolutions and throughputs from kSPS to 10 MSPS, while offering industry-leading performance in noise, linearity, and dynamic range. ADI offers a quick and easily deployed multichannel solution suited to your application’s diverse needs in speed, power, and size. Engineered to accommodate single-ended, differential, and pseudo differential inputs, our multiplexed converters offer the feature set needed for next-generation end systems.
-
40-835A-001 -
Pickering Interfaces Ltd.
The 40-835A-001 (PXI) and 42-835A-001 (PXIe) are single 75 Ohm 16-channel RF multiplexers in a single slot. It has been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz. The design of the 40/42-835A minimizes the injection of noise and unwanted signals into the signal path by careful attention to the mechanical and electrical design.
-
40-835A-101 -
Pickering Interfaces Ltd.
The 40-835A-101 (PXI) and 42-835A-101 (PXIe) are single 75 Ohm 16-channel RF multiplexers in a single slot. It has been designed to exhibit low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost. The MUX has been carefully designed to ensure excellent and repeatable RF characteristics to frequencies of 3GHz. The design of the 40/42-835A minimizes the injection of noise and unwanted signals into the signal path by careful attention to the mechanical and electrical design.