Rubidium Frequency Standards
See Also: Rubidium Standards
-
Product
Standard 0.39 (11.00) - 1.39 (39.00) Non Replaceable General Purpose Probe
MEP-20U
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 25Test Center (mm): 0.635Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 750Overall Length (mm): 19.05Rec. Mounting Hole Size (mil): 20.5Rec. Mounting Hole Size (mm): 0.52Rec. Mounting Hole Remark: 20.5 to 21.5 mil / 0.52 to 0.55 mmRecommended Drill Size: #75 or 0.52 mm
-
Product
Radio Frequency (RF) Recording and Playback Instruments
-
Adivic Radio Frequency (RF) Recording and Playback Instruments
-
Product
Additional Products: Standard Voltage 50 Pin D-Type Cables - Connector to Unterminated
-
The connector to unterminated cable assemblies below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1P-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Frequency Block Converter
FBC
-
The FBC-XX-FB is a full band system can be built upon a Keysight N8975A Noise Figure Analyzer (NFA) or X Series Signal Analyzer with option N9069A. This system allows the user to extend the frequency range of the NFA to allow for accurate noise figure measurements to be performed on a device covering Ka, U, V, E, W bands (26.5-170 GHz), when used with an Agilent E8247C signal generator (or equivalent).
-
Product
Standard 1.50 (43.00) - 4.00 (114.00) Bead Probe
BTP-25HF-4
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.39 (11.00) - 1.39 (39.00) Non Replaceable General Purpose Probe
MEP-20B
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 25Test Center (mm): 0.635Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 750Overall Length (mm): 19.05Rec. Mounting Hole Size (mil): 20.5Rec. Mounting Hole Size (mm): 0.52Rec. Mounting Hole Remark: 20.5 to 21.5 mil / 0.52 to 0.55 mmRecommended Drill Size: #75 or 0.52 mm
-
Product
Ultra High Frequency Vibrometer
UHF-120
-
Polytec?s New UHF-120 Vibrometer Laser-Doppler Vibrometers (LDV) can characterize the out-of-plane vibrations at ultra-high frequencies. Polytec?s UHF-120 extends the vibration frequency bandwidthup to 600 MHz.
-
Product
Standard Accessory Replacement Kit for PP017/PP018
PKIT4-5MM-101
-
Standard Accessory Replacement Kit for PP017/PP018.
-
Product
Suitable for Thermocouple Sensors Approved to ATEX and IECEx standards
TTC200X
-
Approved to ATEX and IECEx standards allowing for use in hazardous area applications.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1L-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Helmholtz Coils (Field Standards)
-
Lake Shore offers four Helmholtz coils for field standards: 2.5 in, 6 in, and 12 in diameter single axis, and the MX-2X-10 double axis coil. Standard field coil (field generation). Field strengths from ˜12 G to ˜30 G. Field accuracy of 0.5%. Field uniformity of 0.5%*. Single axis configuration with 2.5 in, 6 in, and 12 in diameter coils.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1L18-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 1.27 (36.00) - 2.94 (83.35) Battery Probe
CCA-003
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 50Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 78Full Travel (mm): 1.98Recommended Travel (mil): 40Recommended Travel (mm): 1.02Mechanical Life (no of cyles): 100,000Overall Length (mil): 670Overall Length (mm): 17.02
-
Product
Frequency Converter Test Solution Up To 50 GHz
N5245BP
-
The N5245BP provides the N5245B 50 GHz PNA-X network analyzer, application software and accessories for frequency converter test up to 50 GHz. This bundle product
-
Product
Frequency Meter
Reed Type
-
*Vibrating Reed type frequency meters are available in size 72 x 72 & 96 x 96mm suitable 110V, 230V & 440V AC Operation.*Scale 45-50-55 Hz.*Model : SF-72 ( R ), SF-96 ( R ).
-
Product
The Gold Standard for Breast Screening & Biopsy Training
Mammography QA Solutions
-
When the USA mandated Mammography QA requirements via the Mammography Quality Standards Act (MQSA), medical physicists, the ACR and the FDA worked with Gammex to complete the phantom design known today as the 156 Phantom.
-
Product
2GHz programmable frequency dividerValon
3010a
-
The Valon 3010a accepts a wide range of input frequencies and provides three independent, user-selectable, divided outputs. The 3010a is useful for extending the low-frequency range of any signal source down to 5MHz as a 50Ω output or down to 0Hz as a TTL output.
-
Product
Standard 1.53 (43.00) - 4.00 (114.00) Bead Probe
BTP-72HF-4
Bead Target Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1L24-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 5.40 (153.00) Probe
LFRE-39L15-5.4
ICT/FCT Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 50Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 50,000Overall Length (mil): 1,437Overall Length (mm): 36.50
-
Product
Standard Voltage 37 Pin D-Type Cables - Connector to Connector
-
The connector to connector cable assemblies below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
Product
Standard Patchcords
-
VPC's standard and stocked patchcords make patchcord order and delivery quick and easy. Available in signal (QuadraPaddle and TriPaddle), power and coax.
-
Product
Standard 1.60 (45.00) - 4.50 (128.00) General Purpose Probe
EPA-3J
General Purpose Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 35Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard Modal Analysis
-
EDM Modal Standard Modal Analysis provides the user with a complete arsenal of tools, from FRF data selection and parameter identification to results validation and mode shape animation.
-
Product
Standard And Custom Targets
-
Santa Barbara Infrared manufactures a wide range of targets for visible, and infrared/FLIR electro-optical testing. These targets complement our complete line of Visible and IR test products. Our targets are designed to function with one of SBIR’s target wheels. Utilizing a variety of manufacturing techniques, including conventional machining, photochemical etching, electro-deposition, electrical discharge machining (EDM) and laser cutting. SBIR targets are manufactured to exacting mechanical tolerances. SBIR manufactures all of the targets specified by MIL-STD-1859 and the Tri-Service Guide for thermal imager testing.
-
Product
Digital/Analog/Frequency Measurement Module
JT 2149/DAF
-
The JT 2149/DAF is a compact, mixed-signal (Digital/Analog/Frequency) measurement module for use in JTAG Technologies’ widely-used JT 2147 (QuadPod) signal conditioning interface. The DAF module has been designed to replace a regular TAP Pod and provides 28 measurement channels plus a clock generator. When connected to a circuit board via edge connector or test fixture/jig test pins, the module enhances standard digital boundary-scan tests by enabling a series of analog and frequency measurements to be made.
-
Product
High Frequency Current Transformer Clamps
HFCT-20HD & HFCT-60HD™
-
The HFCT-20HD™ and HFCT-60HD™ are high frequency current transformer sensors designed for partial discharge detection on electric apparatus’ ground returns. Made from superior quality materials, it is designed for any environment.
-
Product
Standard Resistors for Temperature Measurement
-
Measurements International Ltd.
High Stability, Split Guard Circuit, Internal Temperature Sensor, Custom Values Available, Includes Calibration Data.
-
Product
Rugged GPS Time & Frequency Reference
VersaSync
-
VersaSync is a high-performance GPS master clock and network time server that delivers accurate, software-configurable time and frequency signals in harsh environments, including GPS-denied areas. Now with M-Code!





























