Rubidium Frequency Standards
See Also: Rubidium Standards
-
Product
UV & Visible Frequency Mixing Module
SolsTiS EMM
-
The SolsTiS External Mixing Module (SolsTiS EMM) provides fully automated tuning in the visible (480-670 nm) and IR (1.1-4.5 µm) with further extensions options into the UV (300-350 nm). It delivers high stability sum and difference frequency mixing of SolsTiS wavelengths with other single frequency sources, primarily via high efficiency single pass mixing in PPLN. This all-solid state solution for wavelength coverage supersedes dye lasers, removing the hazards and instabilities associated with this toxic gain material. SolsTiS EMM delivers unparalleled performance and reliability, enabling you to automatically tune and scan over a broad wavelength range.
-
Product
Standard 1.08 (31.00) - 4.00 (114.00) Long Travel Bead Probe
BPLT-25HF-4
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
Product
Standards and Regulations
-
Is your organization ready to engage in the world of autonomous and electric vehicles?
-
Product
High Frequency Synthesizer
HFS Series 1.25” x 1” x 0.25”
-
*Surface Mount Package *Broadband Designs Available *Optional Internal Reference *Optional Reference Detect Switch *Internal Reference Output Available *Off-the-Shelf Products Available
-
Product
Standard 0.70 (2.00) - 1.70 (4.80) General Purpose Probe
P2662AG-1Q1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 90Full Travel (mm): 2.29Recommended Travel (mil): 67Recommended Travel (mm): 1.70Overall Length (mil): 710Overall Length (mm): 18.03
-
Product
Standard 1.00 (28.30) - 5.40 (153.00) Battery Probe
BIP-10
Battery Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 30Resistance Remark: Probe Resistance Steel: 30 mOhms, Gold plated: 100 mOhmsTest Center (mil): 260Test Center (mm): 6.60Full Travel (mil): 157Full Travel (mm): 4.00Recommended Travel (mil): 126Recommended Travel (mm): 3.20Overall Length (mil): 591Overall Length (mm): 15.00
-
Product
AC Power Sources, Frequency Converter
MAC-01, -02, -03
-
For reliability, all models of the Titan AC Power Sources/Frequency Converters are fully current limit protected against either continuous or transient short circuit or overload conditions. When an overcurrent condition exists, the internal current control loop overrides the voltage control loop and scales back the sinewave drive until it sees a safe output current level.
-
Product
High Frequency RF and Microwave USB Programmable Signal Generators
LMS Series
-
The Lab Brick LMS series of high frequency RF and microwave USB-compatible, synthesized signal generators cover a frequency range from 0.5 MHz - 20 GHz with low noise, fast 100-microsecond switching time, and fine 100 Hz frequency resolution. They require no additional DC supply voltage and offer advanced features such as phase-continuous linear-frequency sweeping, internal/external 10 MHz reference, and optional pulse modulation. GUI software can track and control several connected signal generators, simplifying multiple-signal test setups. Each device stores settings in internal memory, allowing it to power up in a specific instrument state.
-
Product
Frequency Doubling Comb Generator
COMBGEN6DIFF
-
*Differential output - can also provide two separate single ended complementary outputs.*Pulse height of up to +4V peak into 50 ohms, on positive output*Pulse height of up to -4V peak into 50 ohms, on negative output*Rise time < 80pS, FWHM of approximately 120pS*Produces pulse on both edges of input clock, thereby doubling frequency.*Input clock may be sinewave from 50MHz to 2GHz or square wave from 5MHz to 2GHz, producing fundamental comb tooth energy from 10MHz to 4GHz.*Usable energy to >10GHz.*Can drive any load, including short, without damage.*Power Requirements: -12V @ 120mA and +24V @ 80mA
-
Product
Standard -1.44 ( 41.00) - 4.50 (128.00)High Current Probe
HCP-13B
High Current Probe
Current Rating (Amps): 15Average Probe Resistance (mOhm): 25Test Center (mil): 125Test Center (mm): 3.18Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 250,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Spectral Radiant Flux / Luminous Flux Calibration Standards
-
Standard lamps calibrated in luminous flux and spectral radiant flux. Versions with 2-Pi and 4-Pi emission characteristics. Traceable calibrations in the wavelength range from 200 nm to 2500 nm.
-
Product
Standard 1.55 (44.00) - 3.20 (91.00) General Purpose Probe
HPA-50B
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 50Full Travel (mm): 1.27Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 590Overall Length (mm): 14.99
-
Product
Amplifier for the Frequency Range from 2 Hz to 50,000 Hz.s
Trig-Tek™ 203M
Amplifier
Versatile amplifier covers the frequency range from 2 Hz to 50,000 Hz.s and provides has three simultaneous outputs
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T30-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T30-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard Mechanical Calibration Kit, DC To 9 GHz, 3.5 Mm
85033E
Mechanical Calibration Kit
85033E Standard Mechanical Calibration Kit, DC to 9 GHz
-
Product
PathWave BenchVue AC Source Avionics Standard Test Software
BV0028B
-
Control your AC source and accelerate pre-compliance testing as per the avionics and military-standard requirements at ease.
-
Product
Frequency Sources
-
PMI offers a full line of Digitally Controlled Oscillators (DTOs), Dielectric Resonator Oscillators (DROs), Voltage Controlled Oscillators (VCOs) and Frequency Synthesizers covering various frequencies in the 50 MHz to 40 GHz range. All models are designed to withstand stringent military ground or airborne environments. These models use the latest internal digital calibration techniques such that frequency drift over the operating temperature range is minimal. All units offer fast switching speeds and stable frequency outputs with low phase noise. If you do not see exactly what you need, please e-mail your requirement to sales@pmi-rf.com so we can propose an instant solution.
-
Product
Standard 1.00 (28.00) - 1.80 (51.00) General Purpose Probe
P2662BG-2V1S
General Purpose Probe
Current Rating (Amps): 3Average DC Resistance lower than (mOhm): 30Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 68Full Travel (mm): 1.73Recommended Travel (mil): 50Recommended Travel (mm): 1.27Overall Length (mil): 575Overall Length (mm): 14.60
-
Product
Standard 1.10 (31.18) - 4.80 (136.00) Switch Probe
TSP100-F180-1
Switch Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 20Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 197Full Travel (mm): 5.00Recommended Travel (mil): 157Recommended Travel (mm): 4.00Overall Length (mil): 1,990Overall Length (mm): 50.60Switch Point (mil): 59Switch Point (mm): 1.50
-
Product
High Frequency Standard Capacitor
GenRad 1403 Series
-
The GenRad 1403 Standard Air Capacitors are stable, three-terminal standards in decimal values from 0.001 pF to 1000 pF. For measurement at 100 pF and below, a three terminal connection increases the accuracy by eliminating the uncertainty in the measurement introduced by the capacitances between the capacitor terminals and ground.
-
Product
Standard 0.49 (13.89) - 2.50 (70.87) Battery Probe
CP-4C
Battery Probe
Current Rating (Amps): 10Average Probe Resistance (mOhm): 25Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 60Full Travel (mm): 1.52Recommended Travel (mil): 40Recommended Travel (mm): 1.01Overall Length (mil): 311Overall Length (mm): 7.90Overall Length Remark: Overall length does not include tail.
-
Product
Resonant Frequency Testing
E-Meter MK II™
-
Determines resonant frequencies of the three modes of vibration. Material characteristics such as Youngs Modulus of Elasticity, Modulus of Rigidity, Poissons Ratio and Damping Constant can be calculated. Frequencies are automatically scanned in one of four ranges. The system can determine flexural resonance of concrete under accelerated freezing and thawing cycles and aggressive environments.
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1UN-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Frequency Dividers
-
Precision Test Systems manufacturers' various divider boards as options to its range and frequency standards and distribution amplifiers.
-
Product
Standard 6.13 (174.00) - 16.00 (456.00) General Purpose Probe
EPA-5A
General Purpose Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,420Overall Length (mm): 36.07
-
Product
Standard 1.08 (31.00) - 4.00 (114.00) Long Travel Bead Probe
BPLT-25C-4
-
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
Product
Standard 1.53 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-72I-4
ICT/FCT Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 15Test Center (mil): 50Test Center (mm): 1.27Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,700Overall Length (mm): 43.18
-
Product
High Frequency Current Transformer
HFCT
-
The HFCT is a high frequency current transformer designed specifically for picking up partial discharge signals. It has a split core ferrite to allow retrospective fitting to earth straps without the need for disconnection. The durable body has a hinge and a quick release latch, making use quick and easy. The HFCT is constructed with an aluminium body to provide RF shielding and improved performance in noisy environments.





























