Rubidium Frequency Standards
See Also: Rubidium Standards
-
Product
Standards and Regulations
-
Is your organization ready to engage in the world of autonomous and electric vehicles?
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25A-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Bias Ball Probe
POGO-1T30-4-S
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Standard 0.62 (18.00) - 4.00 (114.00) High Performance Lead Free Probe
LFRE-1Z1-4
ICT/FCT Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 500,000Mechanical Life Remark: *Ultra High force products may observe slight decrease in cycle life.Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
Rack Module with Standard Contactors with Anti-Harmonic Filters
MODF Rack
-
Lifasa - International Capacitors, SA
The MODF-RACK control units include, in a compact form, all the components necessary for the operation of a step of a capacitor bank with filters. MODF-RACK modules are divided into two basic blocks: power block and control block. The two blocks are mounted in a small frame to be installed in an electrical panel.
-
Product
Frequency Expansion Modules
-
bsw TestSystems & Consulting AG
Up To 1.5THz For Network Analyzers Modern communication standards, like for instance 5G, place high demands on components (mixers, amplifiers, antennas, etc.), which have to be examined in high frequency bands (millimeter waves); the requirements include: broad frequency coverage, sufficient output power to operate the components under compression, high dynamic range and stability as well as a reduced dynamic content within the spectrum.
-
Product
Standard Voltage 37 Pin D-Type Connectors
-
The connectors below are not compatible with Pickering products, however, are offered for developing a connection solution for use with other products.
-
Product
Standard 0.79 (23.40) - 1.75 (49.60) General Purpose Probe
HPA-40A
General Purpose Probe
Current Rating (Amps): 2Average Probe Resistance (mOhm): 35Test Center (mil): 39Test Center (mm): 1.00Full Travel (mil): 75Full Travel (mm): 1.91Recommended Travel (mil): 50Recommended Travel (mm): 1.27Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 660Overall Length (mm): 16.76
-
Product
Absolute Contamination Standards (ACS)
-
The Absolute Contamination Standard (ACS) is used to calibrate instruments which size and detect particles on the surface of bare silicon wafers. Use ACS to characterize particles, before particles characterize products.
-
Product
Low Frequency RF Broadband Power Sources
-
Class A has RF power source, ideal for Industrial /Scientific / Medical applications. Class AS is a robust source of RF power for ultrasonic, laser modulation, RFI/EMI, plasma generation, general laboratory and industrial applications.
-
Product
Standard 2.20 (62.00) - 4.80 (136.00) General Purpose Probe
EPA-4D
General Purpose Probe
Current Rating (Amps): 7Average Probe Resistance (mOhm): 35Test Center (mil): 187Test Center (mm): 4.75Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 1,320Overall Length (mm): 33.53
-
Product
Standard & Custom Test Fixtures
-
Both standard and custom Test Fixtures from OAI enable the user to integrate the solar cell with the I -V tester. Fixture configurations range from from simple hold down devices to temperature-controlled fixtures with front and back side contact. We invite you to contact an OAI Application Engineer for help with your fixture design. With our expert guidance, you can expect maximum performance from your I -V Tester and Solar Simulator.
-
Product
Radio Frequency Probes (Consumer) HF860PCBGSG016G960MCXfPV1
1021449
-
The Radio Frequency Probes (Consumer) HF860PCBGSG016G960MCXfPV1 is a top-tier component designed to ensure optimal signal fidelity in high-frequency applications. With a pitch of just 6.00mm (or 236 mil), it caters to precision requirements, providing reliable connections across a temperature range of -45°C to +100°C. This makes it ideal for challenging environments where solid performance is crucial. The probe’s design focuses on enhancing electrical performance, offering impressive specifications including a continuous current rating of 5.00A and operating frequency up to 6.00GHz, ensuring it can handle demanding tasks with ease.
-
Product
PAL Standard Pattern Generator
PG315P
-
The MicroImage PG315 pattern generator is designed for simple size and geometry reference applications. The PG315 will overlay one of five standard patterns including a centered cross line, a centered cross hair, a centered target style symbol, a dot grid (cross dot) array, a hatch grid (crosshatch) array.
-
Product
Ultra Low Noise Disciplined Frequency 4220a Standard with Rubidium and OCXO Clean-Up Oscillator
-
Precise Time and Frequency, Inc.
The ptf 4220A is an Ultra Low Noise Disciplined Frequency Standard with rubidium and OCXO clean-up oscillator.The instrument contains a high performance rubidium module, with an extended life design, and very low aging rate, with high quality OCXO o/p for low phase noise.
-
Product
Integrated Frequency to Voltage Converter
FV
-
The FV6 Frequency to Voltage Module provides a convenient method of converting up to six frequency signals to analog voltages that can be fed into common data acquisition equipment.
-
Product
Radio Frequency Probe HF819HSDm011G1270H819AEPPV2
1012608
-
The HF819HSDm011G1270H819AEPPV2 Radio Frequency Probe is an advanced automotive tool designed for precise and reliable measurements in high-frequency applications. Engineered with cutting-edge technology, this probe features a coaxial design that minimizes signal loss and ensures accurate readings across a range of automotive testing scenarios. It operates within a frequency range of up to 1 GHz, making it ideal for modern vehicle diagnostics that demand high-performance electrical solutions.
-
Product
DC Power Source for Standard Lamp
DC502
-
DC502 is CONSTANT CURRENT DC POWER SUPPLY for standard lamp. Function and technical indexes are as follows: • output voltage 4 grades: 6V/12V/24V/50V • output current: DC 0~2.5A (adjustable) • Output current drift at full scale: ±0.05% reading value/10 mins • Monitor range of ampere meter: 0.0000A ~1.9500A, 1.950 A ~2.500A • Accuracy of ampere meter: ± (0.08% reading value + 0.02% full scale) • Max output power: 80W • Continuous working time: 8 hours • Work environment: Temperature 0℃ -25℃, humidity ≤ 85%R.H, supply source: AC220 ±10%, 50/60HZ • Holding conditions: -20~50℃ humidity < 75%R.H • Outside dimension (W×H×D): 333mm×114mm×307mm • Weight: about 8kg • Power: about 1000VA
-
Product
Frequency Response Analyzers
-
Frequency Response Analysis (also referred to as Transfer Function Analysis) measures the output spectrum of a system relative to a stimulus, and is used to characterize the dynamics of the system under test. The technique measures the magnitude and phase relationship between output and input waveforms as a function of frequency. The input signals may be from a wide range of sensors including acoustic (microphones/sonar), mechanical (accelerometers/displacement transducers), optical (photodetectors), and electrical (amplifiers).
-
Product
Calibration Standards, Calibration Services
-
ISO 17015 traceable calibrated reference lamps, detectors and reflectors for the calibration and adjustment of sensors and measurement devices for light, optical radiation and light reflection. We offer as well many ISO 17025 calibration services.
-
Product
Standard 1.50 (43.00) - 4.00 (113.00) High Performance Lead Free Probe
LFRE-25V-4
ICT/FCT Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Mechanical Life (no of cycles): 1,000,000Overall Length (mil): 1,300Overall Length (mm): 33.02
-
Product
(125×150×22mm) Single-Channel Full Function Standard Booster EDFA module
EATV5100-FM05
-
Hangzhou Huatai Optic Tech. Co., Ltd.
The EATV5100-FM05 standard Booster EDFA module provides high power, high reliability, and superior optical performance in an industry standard form factor. This product enables deployment fo flexible, high-density optical networks, while reducing capital and operating applications' requirements. This module is ideal for today's highly dynamic networks and cost sensitive market. EATV5100-FM05 Full Function Booster EDFA Module adopts Standard Versions for Single Channel and Narrowband. The EDFA includes a cooling pump laser, input monitor and input isolator, output monitor and output isolator, and a reel of optimized erbium-doped fiber. These components are contained within a standard 125×150×22mm package.
-
Product
AC Power Source, Frequency Converter
BL1350 Series
-
Behlman's BL1350 AC Power Supply / Frequency Converter / Inverter, requires just 3.5" of rack height, and weighs as low as 45 pounds, yet it delivers 1350 VA of quality AC power. In the BL 1350, you'll find the quality features you expect from Behlman, fully adjustable frequency and voltage, total harmonic distortion of less than 0.5%, high efficiency, plus excellent line and load regulation.
-
Product
High Resolution Frequency Response Analysis (FRA) System
TR-AS FRA
-
The Frequency Response Analysis (FRA) on power transformers is used for diagnosis at works, after putting into operation and for maintenance on site. The frequency dependent admittance is determined and recorded as fingerprint.
-
Product
Frequency Synthesizer-Detector
SD-31
-
The Model SD-31 Synthesizer-Detector is a high output crystal signal generator of precisely known frequency combined with a sensitive, selective detctor for RF bridge measurements of AM antenna impedance. Packaged in a single light-weight battery-powered unit, the SD031 complements bridges such as the General Radio 1606, 916, and the Delta OIB-1.
-
Product
Standard 0.50 (14.00) - 3.40 (96.00) Non Replaceable General Purpose Probe
C-S-R
General Purpose Probe
Current Rating (Amps): 5Average DC Resistance lower than (mOhm): 30Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 45Full Travel (mm): 1.14Recommended Travel (mil): 30Recommended Travel (mm): 0.76Overall Length (mil): 395Overall Length (mm): 10.03Rec. Mounting Hole Size (mil): 46.5Rec. Mounting Hole Size (mm): 1.18Recommended Drill Size: 56
-
Product
Radio Frequency Probes (Industrial) HF860BMAm014G530MCXfS
1039103
-
The HF860BMAm014G530MCXfS Radio Frequency Probe is an advanced industrial tool designed for precision in RF measurements. Operating effectively within a temperature range of -45°C to +100°C, this coaxial probe ensures reliable performance across various environments. With a pitch of 6.50 mm, it showcases robust construction using high-grade materials like beryllium copper for the plunger and brass for the barrel, both plated with gold. This enhances the probe's durability and minimizes signal loss, making it suitable for high-frequency applications up to 4 GHz.
-
Product
Rubidium Oscillator
-