  • Dual-Port HS-1760 Test & Simulation PXI Express Module

    PXIe-C1760 - Avionics Interface Technologies

    3U PXI form factor fits into PXIe or PXI hybrid slotTwo independent ports programmable as NC or NT(s) simultaneouslyTwo SFP sockets accepts FC-0 AS5653 or AS5625/AS5627 transceiversSupports NC-to-NT transfers, NT-to-NC Transfers, Mode Codes, and BroadcastFull control of sequence and exchange managementSupports large file exchangesFull Monitoring of all Bus TrafficTriggering and FilteringFull Error InjectionSupports DMA for high speed streaming of data to/from the boardIRIG-B Time Code Encoder/Decoder for Data CorrelationOptional Special FC-0 physical layer compliance with SAE AS5653Optional fcXplorer Analyzer for decoding HS1760 frames

  • Gas Detector

    MGS-450 - Bacharach, Inc.

    Bacharach’s MGS-450 Gas Detector makes compliance with mechanical equipment room and refrigeration safety codes simple and easy, saving time and money on equipment and installation. Using the MGS-400 App, users can intuitively use, commission and maintain their gas detection system without the need for specialty training or tools. Pre-calibrated sensor modules simplify maintenance, take minutes to exchange and do not require the use of calibration gas. The MGS-450 sensor can trigger additional audio-visual alarms and act as a standalone gas detection system, or integrate easily into a BMS / BAS or with Bacharach’s MGS-402 or MGS-408 Gas Detection Controllers.

  • Gas Detector

    MGS-460 - Bacharach, Inc.

    Bacharach’s MGS-460 Gas Detector makes compliance with mechanical equipment room and refrigeration safety codes simple and easy, saving time and money on equipment and installation. Using the MGS-400 App, users can intuitively use, commission and maintain their gas detection system without the need for specialty training or tools. Pre-calibrated sensor modules simplify maintenance, take minutes to exchange and do not require the use of calibration gas. The MGS-460 sensor can trigger additional audio-visual alarms and act as a standalone gas detection system, or integrate easily into a BMS / BAS or with Bacharach’s MGS-402 or MGS-408 Gas Detection Controllers.

  • EMC / EMI Testing

    National Technical Systems

    NTS is known worldwide as the industry leading provider of Electromagnetic Compatibility (EMC) and Electromagnetic Interference (EMI) engineering and compliance services. Our Program Managers and Subject Matter Experts work closely with you, conducting extensive technical reviews to determine your needs and provide a customized service. Whatever you require to speed your product to market — engineering, design analysis, testing, technical training — NTS will customize solutions to meet all of your needs. We offer a wide range of EMC and EMI services to seamlessly take your design from concept to final product.

  • Composite Salt Spray Test Chamber

    YWX/Q-010X - Lisun Electronics Inc.

    Composite Salt Spray Test Chamber stimulate the actual natural conditions to do accelerated corrosion test, all the testing are based on common states on the natural environmental: such as combine with salt spray, hot air drying, humidity, low temperature and so on. The test samples are widely used on the intense changes in the environment, like automobile parts, aviation equipment, building materials, coating, electric and electrical machinery so on. YWX/Q-150X series is  full compliance with ASTM D4728I, EC 60068-2-1, IEC 60068-2-14 and EIA/JEDEC JESD22-110-B standard requirements etc.

  • Gas Detector

    MGS-410 - Bacharach, Inc.

    Bacharach’s MGS-410 Gas Detector makes compliance with mechanical equipment room and refrigeration safety codes simple and easy, saving time and money on equipment and installation. Using the MGS-400 App, users can intuitively use, commission and maintain their gas detection system without the need for specialty training or tools. Pre-calibrated sensor modules simplify maintenance, take minutes to exchange and do not require the use of calibration gas. The MGS-410 sensor can trigger additional audio-visual alarms and act as a standalone gas detection system, or integrate easily into a BMS / BAS or with Bacharach’s MGS-402 or MGS-408 Gas Detection Controllers.

  • On-Site EMC Testing and Evaluations

    Washington Laboratories LTD.

    There are several reasons to perform product compliance testing at specific location, rather than at a test laboratory. A major reason is that the equipment may be physically too large for a test laboratory. The other reason is that special support equipment or infrastructure is needed to operate the equipment. For example, the electricity supply may have specific voltage or amperage requirements that cannot be accommodated in the laboratory. Other operational needs may include mechanical services such as air-handling, chemical requirements, other support equipment. Other reasons may include security issues or other special access issues relating to sensitive equipment and/or intellectual property.

  • Solar Radiation Testing

    Keystone Compliance

    Solar radiation test setups are custom designed for each test setup. Solar arrays can be provided for small or large test articles. Arrays are designed and calibrated prior to placement of the test article. Testing takes place within any of our various temperature chambers. Solar arrays are microprocessor controlled and are capable of delivering greater than the 1,200 watts per meter squared as required by most commonly used test specifications. Custom programs can be designed to simulate real world test cycles of sunrise to sunset. Keystone Compliance offers Solar radiation testing for heating effects only.

  • Ethernet, GPIB And USB To Modbus RTU Interface Board

    ICS Electronics

    ICS's Model 9009 is a multi-interface board that allows Ethernet, GPIB or USB control of Modbus RTU devices. The Ethernet port has VXI-11 protocol for easy control by the following computer systems without special drivers: LINUX, UNIX, SunOS, MAC OS X, HP-UX, IBM-AIX and Windows 2K or later Windows systems. VXI-11 is one of the 9009's Ethernet protocols. ICS Electronics is the premier VXI-11 device supplier with 100% VXI-11 compliance in every product. See our extensive Application Notes or download our VXI-11Tutorial and the VXI-11 Specification for more information about the VXI-11 Standard.

  • DataComm

    SCHILLER AUTOMATION GmbH & Co. KG

    With ever-growing performance, accuracy, and precision required by 112G/800G PAM4 solutions, Wilder has designed a robust HCB and MCB fixtures to support OSFP-XD, QSFP-DD, OSFP and SFP-DD compliance testing. In addition, CMIS_GUI Software provides: Displays of many of the settings and Controls in the Module including Lane States, Module Power States and Optical Power. Alarms and Warnings for Module Temp and Vcc and Optical Power Controls for Module Power, Margins, and read access to Descriptors and Data Path Configuration. Direct Read/Write access to the I2C and CMIS Memory Map as well Scripts that directly access the CMIS Memory Map Registers.

  • EMC Testing

    Keystone Compliance

    Keystone Compliance is a unique EMC test facility because of our focus on assisting our customers achieve the measurements and certifications that they are seeking. Our lab features three 3-meter EMC chambers and two military/aerospace EMC chambers. In addition to the chambers, the lab significant ground planes, equipment and software that optimize the efficiency of the testing. EMC TestingKeystone Compliance is a unique EMC test facility because of our focus on assisting our customers achieve the measurements and certifications that they are seeking. Our lab features three 3-meter EMC chambers and two military/aerospace EMC chambers. In addition to the chambers, the lab significant ground planes, equipment and software that optimize the efficiency of the testing.Our EMC/EMI testing capabilities include but are not limited to:Radiated immunity testing up to 200 V/m from 10 kHz to 40 GHzRadiated emissions testing up to 40 GHzSurge testing to 10kV/10kA – and higherElectrostatic Discharge “ESD” testing up to 30 kVConducted immunity testing to levels well above the highest defined “standard” levelsMagnetic field immunity testing up to 100 A/m continuous and 1000 A/m short/impulseCustomized transient waveforms to extend level, duration and/or repetition of the standard’s definitionShielding Effectiveness from small panels and boxes all the way up to large enclosures and cabling, with a wide dynamic range all the way to 40 GHzWhat differentiates Keystone Compliance from other EMI test labs is our consultative engineering and expedited EMI test reports. Our staff understand EMC/EMI testing and has extensive experience with radiated immunity, radiated emissions, conducted immunity, conducted emissions, surge, ESD and shielding effectiveness testing. We also cater to specialized testing requirements. If you do not see the test standard or testing requirement you are looking for, please contact us as we may still be able to assist you.For more information about our scope of accreditation, please visit the links below.CISPR StandardsIEC/EN Product Family StandardsIEC/EN Test StandardsISO, SAE and Vehicle StandardsMilitary StandardsFCC, North American and International StandardsShielding Effectiveness TestingLightning and Surge Testing

  • HBM Verification Tester

    HBM-VT - High Power Pulse Instruments GmbH

    - HBM pulse generator verification tester according ANSI/ESDA/JEDEC JS-001 up to ±10kV- To be used in HBM test and qualification labs for regular pulse generator specification compliance test in order to fulfill lab audit and certification requirements- Fully automatic compliance test and verification of HBM pulse generators regarding ANSI/ESDA/JEDEC JS-001 normative standard at 3 different load conditions: Short Circuit, 500 Ω, and a reference diode at VBR=15 V reverse breakdown voltage, including DC test- Parameter evaluation and verification of the transient HBM current waveforms: Peak Current, Rise Time, Decay Time, Maximum Ringing Current- Optionally available upgrade for all HPPI TLP-3010C, 4010C, 8010A, 8010C, HBM-TS10-A hardware systems in combination with HBM-S1-B (6kV) pulse generators (upgrade on request)- Fully automatic test report generation (PDF)- Electrically floating (no fixed system ground): The HBM loads, current sensor output, USB control interface and the enclosure are electrically floating. There is no limiting system ground which may introduce common-mode interference induced HBM current measurement errors.- Isolated industrial full-speed USB control interface- Isolated power supply derived from USB port- Compact size 126mm x 82.5mm x 44.5mm

  • Mechanical Test Head Housing

    esmo AG

    a result of more than 10 years' experienceavailable with integrated manipulatorfully integrated docking and board lockingtest housing mechanics design as per customer specificationssuitable for individual and high-volume productionstandard and customized dimensionsno limitation in size and electrical power capacitiesquick and easy locking and unlocking process for board changelarge application space load boardoptional number of channel boards as per customer specificationsfamily/DUT board connection achieved by high-end double-ended spring probes - 50 Ohmhigh-end cooling fansfacilitated adaptation with all available manipulator solutionsdocking design in compliance with customer internal docking standards/dimensionsdocking force as per customer specificationscenter of gravity fully compensated

  • Trace-Level Chemiluminescence NO/NO2/NOx Analyzer

    Model T200U - Teledyne Advanced Pollution Instrumentation

    The Model T200U Trace-level NO/NO2/NOx analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven chemiluminescence principle and is designed to allow ultra-sensitive measurements with a lower detectable limit of 50 ppt while still meeting the requirements for use as a US EPA compliance analyzer.The Model T200U combines a gold plated reaction cell with an enhanced performance pump, special low noise photomultiplier tube, and unique signal conditioning to provide exceptional sensitivity. In addition, a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer.

  • EMC/EMI

    Schaffner

    Harmonic filters help to obtain compliance withinternational standards like e.g. IEEE 519-1992 or EN 61000-3-12, and with local utility codes. They reduce electrical andthermal stress upon the electrical infrastructure, eliminate the risk of harmonics-related reliability problems, and supportlong-term energy efficiency and cost savings. Ecosine passive filters are the industry standard for 6-pulse rectifiers andnon-regenerative motor drives to achieve the often specified level of < 5% THID. Ecosine active harmonic filters providelatest generation digital technology. With a response time of less than 300 µs an efficient harmonics mitigation, powerfactor correction, and load balancing is achieved in real time.