Filter Results By:

Products

Applications

Manufacturers

Detectors

register the presence of a stimuli.

See Also: Metal Detectors, Particle Detectors, Sensors, Charge Sensitive Preamplifiers, Checkers


Showing results: 436 - 450 of 684 items found.

  • 64 Channel 16 bit 125 MS/s Digitizer

    VX2740 - CAEN S.p.A.

    The VX2740 Digitizer is a 64-channel digital signal processor for radiation detectors in a VME64X form factor. It offers not only waveform digitization and recording but also Multi-Channel Analysis for nuclear spectroscopy using Silicon strip, segmented HPGe, Scintillation detector with PMTs, Wire Chambers, and others.

  • X-ray Analytical Microscope (Micro-XRF)

    XGT-9000 - HORIBA, Ltd.

    - <15µm probe size with ultra-high intensity without compromising sensitivity or spatial resolution. - High resolution cameras and multiple illumination modes to help capture images.- Dual types of detectors for transmission and fluorescent X-rays.- Detectable element range down to carbon with a light element detector.

  • Illuminance Meters

    Konica Minolta Sensing Americas, Inc

    Illuminance meter products are single element detectors that measure photometric brightness falling upon a surface. It is measured in footcandles or in lux. The Konica Minolta illuminance meters measure the amount of light that strikes a surface. These instruments display illuminance in either lux or foot-candles and they are lightweight, compact and portable.

  • Activity Detection Unit

    DG009-M1 - Teledyne Defence & Space

    Many advanced EW receivers, particularly those associated with ECM jamming systems, do not require the high resolution frequency information associated with a DFD or IFM based receiver. This is typically the case where a single pulse present within a broad frequency band is required to be detected and instantaneously down-converted to an IF band.TDS manufactures a range of Frequency Activity Detectors (FADs) also known as Activity Detection Units (ADU) which perform frequency measurement of an RF pulse and output data in as little as 15ns. The basis of these products is TDS’s ability to produce high performance broadband channelisers and integrated detectors. These devices are ideal for receivers which must operate in very high pulse density environments.

  • *Laser Pyroelectric Energy Sensors

    mks Ophir

    Pyroelectric sensors for measuring repetitively pulsed energy at up to 25 kHz. These sensors use a pyroelectric crystal that generates an electric charge proportional to the heat absorbed. The response time of the pyroelectric sensor depends on the time it takes for the heat to enter the crystal and heat it up. For metallic type pyro detectors, this time is tens of μs and thus the metallic type can run at a high repetition rate. For the BF and BB type, the response time is milliseconds with a correspondingly lower repetition rate. Ophir pyroelectric detectors have unique and proprietary circuitry that allow them to measure long pulses as well as short pulses and work at a high duty cycle, i.e. where the pulse width is as much as 30% of the total cycle time.

  • Electrostatic Capacitance-Type Non-Contact Thickness Meter

    CL-5610 series - Ono Sokki

    The CL-5610/5610S is used to perform non-contact thickness measurement of objects under measurement including conductors, semiconductors and insulators in combination with the new-developed VE series capacitance type gap detector. The CL-5610/5610S can be connected up to 2 gap detectors and also used as 2-ch displacement meter.

  • Oxygen / Hydrogen Analyzer

    ELEMENTRAC OH‑p 2 - ELTRA GmbH

    The new ELEMENTRAC OH-p 2 is a powerful and robust elemental analyzer for measurement of oxygen and hydrogen concentrations in inorganic samples like steel, iron, copper or ceramics. The highly sensitive NDIR and thermal conductivity detectors reliably detect element concentrations from low ppm content to high percentages.

  • Oxygen / Nitrogen Analyzer

    ELEMENTRAC ON‑p 2 - ELTRA GmbH

    The new ELEMENTRAC ON-p 2 is a powerful and robust elemental analyzer for measurement of oxygen and nitrogen concentrations in inorganic materials like steel, iron, copper or ceramics. The highly sensitive NDIR and thermal conductivity detectors reliably detect element concentrations from low ppm content to high percentages.

  • Heat Detector Testing

    Solo 461 - Detectortesters

    Functional checking of heat detectors, with a genuine heat source, is now required by major national standards around the world. Testing with heat sources not designed for the purpose can be both dangerous and damaging. The Solo range of heat detector testing equipment, designed specifically for the purpose, provides a genuine professional’s solution.

  • Small/Medium Capacity Type High-Speed Rotation Torque Detector

    TH-2000/1000 Series - Ono Sokki

    The TH-1000 series torque detectors employ a new magnetic phase difference method with improving functionality while maintaining the advantages of Ono Sokki's conventional torque detectors. They incorporate high durability and long service life---the biggest features of our torque detectors. The new magnetic phase difference method does not require AC power supply to an auxiliary motor for rotation detection change. TH-1000 series is a standard type torque detector with the rotation speed range up to 6000 r/min. The TH-2000 series is a high-speed rotation type which can be used for torque characteristic test of high-speed rotating motor such as an EV/HEV motor, a centrifuge machine or the like. The characteristic data of the detector can be automatically set up on the TH-5100 torque meter when power is turned on.

  • Light Analysis

    Thorlabs, Inc.

    Welcome to Thorlabs; below you will find links to detectors and instrumentation that measure the various properties of light, a subset of our entire line of photonics products. Thorlabs offers an extensive selection of instruments that measure the properties of light. Our versatile power and energy meters can be used with over 25 different sensors in order to make NIST-traceable power and energy measurements. If the convenience of a meter is not desired, our selection of detectors includes basic photodiodes (uncalibrated and calibrated), photodetectors (biased, amplified, and avalanche), CCD and CMOS arrays, position detectors, integrating spheres, and photomultiplier tubes. The Beam Characterization category contains beam profilers (camera and scanning slit), a wavefront sensor, spectrometers, and interferometers, while the Polarimetery link leads to a selection of instruments used to measure and control the polarization of light.

  • Oxygen / Nitrogen / Hydrogen Analyzer

    ELEMENTRAC ONH‑p 2 - ELTRA GmbH

    The new ELEMENTRAC ONH-p 2 is a powerful and robust elemental analyzer for measurement of oxygen, nitrogen and hydrogen concentrations in inorganic materials like steel, iron, copper or ceramics. The highly sensitive NDIR and thermal conductivity detectors reliably detect element concentrations from low ppm content to high percentages.

  • Analog & Digital Gas Controller

    MX 32 - Teledyne Gas & Flame Detection

    We introduce the new MX 32, a controller that takes analog & digital inputs and covers all needs for a wide variety of applications.The MX 32 is a compact, low-profile controller that continuously monitors gas detection and more generally any 4-20 mA, MODBUS RS485 signal from compatible detectors.​

  • Metal Detection Pipeline System for Vacuum Fillers

    HDS - Mettler-Toledo, LLC

    Metal detection systems for sausage manufacture and inspection of high viscosity liquids. The maximum capacity to detect all metal contaminants combined with stable on-line performance. Full stainless steel construction and sealing standards up to IP69K make HDS pipeline detectors suitable for the harshest meat processing environments.

  • Potentiostats and Galvanostats

    Bank Elektronik

    Potentiostats are widely used in research: materials science, corrosion research and active corrosion control require potentiostats. In analytical chemistry, methods like cyclic voltammetry have equal rights as chromatography and spectroscopy. The core of analysing instruments like gas detectors, blood sugar meters and many others is a potentiostat.

Get Help