Charge Sensitive Preamplifiers
See Also: Detectors
-
Product
Charge Sensitive Preamplifier-Discriminator
A101
-
Model A101 is a hybrid charge sensitive preamplifier, discriminator, and pulse shaper developed especially for instrumentation employing photomultiplier tubes, channel electron multipliers and other low capacitance charge producing detectors in the pulse counting mode. The A101 is widely used in laboratory and commercial applications for mass spectrometers, laboratory and research experiments, aerospace instrumentation, medical electronics, and electro-optical systems.
-
Product
Preamplifiers
-
The primary function of a preamplifier is to extract the signal from the detector without significantly degrading the intrinsic signal-to noise ratio. Three basic types of preamplifiers are available: the current-sensitive preamplifier, the parasitic-capacitance preamplifier, and the charge-sensitive preamplifier. ORTEC manufactures a preamplifier to fit your detector, your application, and your budget.
-
Product
Pre-Amplifiers
MPR, MDA series
-
MPR, MDR series provides low noise, high gain and wideband to improve dynamic range for emission testing. We also offer customized model for variable requirments.. Example 30M-1000MHz with band-pass filter Amprifier unit for connecting antenna directly
-
Product
Preamplifiers
AH-series
-
A broad mix of in-line preamplifiers and accessories are offered to enhance hydrophone measurements by increasing the gain, preserving the flatness response, extending the dynamic range, and minimizing reflections.
-
Product
Charge Amplifier
-
This compact Charge Amplifier has 3 signal routes.When it is used as the Charge Amplifier for the vibration analysis systemWave Stocker, all setups are possibleby the upgraded software.
-
Product
Charging Sets(AP)
-
The Parker Charging kit is an indispensable instrument for checking, adjusting or filling nitrogen into most of the hydraulic accumulators available on the market.
-
Product
Charge System Safety
-
Renesas' charging system safety circuits are optimized to provide a redundant safety protection to an Li-ion battery charging system by monitoring input voltage, battery voltage and charge current.
-
Product
Spectral Sensitivity Measurement
-
It is a device which measures the spectral sensitivity characteristics and quantum efficiency of various solar cells by irradiating solar cells with monochromatic light of constant energy and constant photon without wavelength dependence. We are constantly monitoring irradiation light quantity with our real real time light quantity monitor control system and are not influenced by fluctuation of light source, so it is a well-established control system with excellent measurement stability and measurement reproducibility.
-
Product
Current Preamplifier
1211
-
The model 1211 Current Preamplifier was designed to provide all of the features required of a modern laboratory preamplifier. It measures cur rents with full scale sensitivity ranging from 10 to 10 amperes.
-
Product
Programmable Current Preamplifier
99539
-
The Model 99539 is a modular, multi-channel current preamplifier with parallel, logic level, gain control input. It consists of circuit boards which plug into a 3 1/2" high by 19" wide rack chassis.
-
Product
Low Noise Preamplifier
-
The UPL-3001 preamplifier is a high performance solution for the low-noise amplification of ultrasonic signals. Designed for signals ranging from 0.5 to 300 MHz, the small and lightweight, rugged unit is perfect for remote applications. This is ideal for P&C, TT, AUT or TOFD inspection.
-
Product
Sensitivity Testing
-
Response Dynamics Vibration Engineering, Inc.
Sensitivity testing involves making predictions of system response to environmental disturbance. The significance and importance of the system sensitivity estimates is very often overlooked. This gets companies in trouble and is one of the top reasons why we are called upon to provide timely solutions. Most teams are focused on getting their product to work and get it out the door. An engineering team will often not know how to quantify what to expect in the customer environment and how to test for those expected disturbances. We design hundreds of sensitivity tests and can explain the important concepts to consider in designing the tests and making the right measurements that allow for sound estimates of system response. This is an important expertise we use in our vibration, acoustic and magnetic field consulting services.
-
Product
Thermal Sensitivity Tester
NTE-2A
-
The NTE-2A Thermal Probe is a sophisticated, non-invasive device for the clinical evaluation of neuropathy and the assessment of short fiber neurological function. Individual thresholds are compared to normals to statistical normals. These results provide an accurate means of tracking chronic changes in small fiber nerve function. It can be used for pain studies and in any application were a variable, accurately-controlled temperature stimulus is required. The NTE-2A is often used in conjunction with the Vibratron II to assess peripheral neuropathies.
-
Product
Testing Kit Charging Machine
REOO RO-GZS02
-
REOO RO-GZS02 Testing Kit Charging Machine for PV Module Manufacturing is designed for PV module manufacturing, enabling stable equipment performance for photovoltaic production workflows. Built for solar factories, it supports line compatibility.
-
Product
High Sensitivity Reed Relays
Series 86
-
General purpose relays - As series 80 and 88 but with coil resistances typically twice as high
-
Product
Capacitor Charging Power Supplies
-
Excelitas Capacitor Chargers are tailored to meet your exact needs by configuring modular platforms based on proven designs. Single-phase AC input designs are capable of up to 6 kW of output power and our three-phase designs provide up to 35 kW of output power.
-
Product
Surface Charge and Zeta Potential
-
Surface analysis is a vital method for qualifying new materials in technical and biological applications. Surface charge analysis empowers users to closely monitor the surface chemistry from small particles in the nanometer range up to large wafers. Gain insights into modifications resulting from surface treatment and surface interactions with natural environments under near-ambient conditions. Get a competitive edge in optimizing existing products and developing new ones using the Anton Paar instruments which offer zeta potential measurement for a wide range of applications.
-
Product
Charge Controller
-
The intelligence of an AC charging station or an AC charging infrastructure is largely determined by the charge controller used. A smart charge controller has the primary task of controlling and monitoring the charging process of an electrical vehicle.The features that characterise a smart charge controller include communication with a backend system and the associated authorisation of users, as well as the efficient distribution of load currents by means of dynamic load management to prevent an overload of the existing AC system.
-
Product
Microphone Preamplifier
426A11
-
1/2-inch ICP preamplifier with gain and filter switches (for prepolarized microphones)ICP(R) low noise preamplifier with gain, filters, and TEDS
-
Product
Mm-Wave High Sensitive Power Meters
-
The DPM-xx is a single-channel average power meter for RF to millimeter wave frequencies that measures absolute power from 10 MHz to 220 GHz.
-
Product
Thermal Sensitive Parameter Selector
UI9600
-
Parameter measured under normal temperature:1) β (0-99)2) Switching time T (0.01μs-99.9μs), including Tr, Ts, Tf3) VCES (0-2V), VBE (0-2V)4) Leakage current ICEO (0.01μA-99.9mA)5) Withstand voltage BVCEO (50V-650V)• Parameter measured under high temperature: VBE, β, ICEO
-
Product
Scienlab Charging Discover Test Software
SL1093A
-
The Scienlab Charging Discover test software controls the Scienlab Charging Discovery System (CDS). With this up-to-date, user-friendly software, you can operate the system, visualize measured values, record test sequences, and generate reports for trusted insights.
-
Product
AC/DC High Sensitivity Clamp-On Current Probe
N7026A
Oscilloscope Probe
The Keysight N7026A is a 150 MHz bandwidth, active current probe for InfiniiVision and Infiniium oscilloscopes. The probe features wide and flat bandwidth (DC-150 MHz), lower noise (<250 µArms), and wide input range (up to continuous 30 Arms or non-continuous 40 Apeak). This enables you to measure down to 1 mA/div, giving you a much more accurate view of your low-level signals.
-
Product
Charge Converter
CH-6130/6140
-
The CH-6130/6140 charge converter is a simplified type of charge amplifier converting charge signal to voltage.It can be connected directly to an input BNC connector of a CCLD applicable equipment such as FFT analyzer or vibration comparator, enabling direct connection of a charge output pickup without suing a box type amplifier.
-
Product
C-Band DWDM Pre-Amplifier EDFA (WPA-C)
HWA4300 (With SNMP)
-
Hangzhou Huatai Optic Tech. Co., Ltd.
Huatai HWA4300 series, is designed for C-Band 44 waves or 88 waves DWDM system design Pre-Amplifier gain flatness. Products using the most excellent optical performance, the most advanced electronic control technology and comprehensive software features, has a wide operating wavelength range, Low noise, excellent gain flatness characteristics and transient characteristics.
-
Product
DC/DC With UPS And Charge Controller
PCM-PS402-512
DC Converter
WINSYSTEMS’ PCM-PS402-512 is a wide input range, triple output PC104 DC/DC converter with a built-in battery charger and uninterruptable power supply (UPS) controller. Designed for harsh environments, the power supply operates from -40° to +85°C without a fan or heatsink making it ideal for industrial applications.
-
Product
Preamplifiers
LNA Series
-
Low noise amplifier with 12.5 dB of gain covering the nominal frequency range 1 MHz to 3 GHz and can be used in the range from 200 kHz to 4 GHz. With its high gain and low noise figure, it will significantly increase the sensitivity of virtually all spectrum analyzers and other RF measuring instruments. All measuring instruments have a 'noise figure', which is a measure of how good the instrument is at measuring low level signals, the lower this figure, the better, although the lowest signal level will still be governed by the measurement bandwidth. A typical spectrum analyzer may have a noise figure of 20 dB or more, whereas a typical receiver may have a noise figure of 10 dB. The preamplifier has a noise figure of typically 4 dB, significantly enhancing the low level performance of such instruments, enabling signals that were previously masked by noise to be seen.
-
Product
Smart Refrigerant Charging Kit
HUB4
-
UEi Test & Measurement Instruments
The HUB4 gives the ability to wirelessly get Vapor and Liquid pressures via the WPP1 probes and Vapor and Liquid temperatures via the WPC1 probes, all via the free UEi Hub App. Easy to use and a rugged design make the App and probes an excellent addition to any technician's toolbox.
-
Product
High Sensitivity Shock0 to 5g
TGP-0605
-
The TGP-0605 measures low level impacts and can be used for machine condition monitoring and the monitoring of expensive and/or fragile shipments.