Showing product results. 1 - 15 of 26 products found.
-
DCS-120 - Becker & Hickl GmbH
*FLIM Upgrade for Existing Conventional Microscope*Two Fully Parallel TCSPC FLIM Channels*Compact bh Simple-Tau or Power-Tau System*Scanning by Fast Galvanometer Mirrors*Channel Seperation by Dichroic or Polarising Beamsplitters*Individually Selectable Pinholes and Filters*One or Two BDL-SMN or BDS-SM ps Diode Lasers*Two Fully Confocal Detection Channels*Two HPM-100-40 GaAsP Hybrid Detectors*Optional: Two HPM-100-06 Hybrid Detectors, IRF Width < 20 ps FWHM*Optional: HPM-100-50 Hybrid Detectors for NIR FLIM*Optional: Multi-Wavelength FLIM*Excellent Time Resolution: Electrical IRF Width 6.5 ps FWHM*Time Channel Width Down to 813 fs*Megapixel FLIM, Up to 2048 x 2048 Pixels at 256 Time Channels*Simultaneous FLIM/PLIM*Wideband Version, Compatible with Tuneable Lasers*Electronic Pinhole Alignment*Z-Stack FLIM Acquisition with Zeiss Axio Observer Z1*Optional: Spatial Mosaic FLIM via Motorized Sample Stage
-
Becker & Hickl GmbH
Designed and manufactured by Becker & Hickl - bh offers a wide range of detector types as photomultiplier tubes (PMC), hybrid photo detectors (HPM), single-photon avalanche diodes (SPAD) as well as multi-channel- and multi-spectral detectors. The detection range covers the wavelengths from UV to the NIR and time resolutions spanning from tens of ps to hundreds of ps suitable for anti-bunching, FCS, FLIM, PLIM and other applications. bh guarantee that their TCSPC modules work with any photon counting detector and reach the fastest possible IRF width.Choose your detection now:
-
Becker & Hickl GmbH
*Hybrid Fiber System With Implantable Fiber Tip*Tip Removable from Fiber System*Seperate Excitation and Detection Fibers*Extremly Low Background Fluorescence*One or Two bh ps Diode Laser (BDS-SM or BDL-SMN Series)*High-Efficiency HPM-100-40 or -50 Hybrid Detector*Optional: Multi-Wavelength Detector
-
SP2 / SP5 / SP8 - Becker & Hickl GmbH
*Two Fully Parallel TCSPC FLIM Channels*Compact bh Simple-Tau or Power-Tau System*Two HPM-100-40 GaAsP Hybrid Detectors*Optional: HPM-100-06 Hybrid Detectors, IRF Width < 20 ps FWHM*Excellent Time Resolution: Electrical IRF Width 6.5 ps FWHM*Time Channel Width Down to 813 fs*Megapixel FLIM, Up to 2048 x 2048 Pixels at 256 Time Channels*Identical Systems for Multiphoton FLIM and Confocal FLIM*Detectors can be Swapped Between RLD Port and X1 Port*Systems are Modular: More FLIM Channels can be Added
-
A1 / C1 / C2 - Becker & Hickl GmbH
*bh FLIM Embedded in Nikon NIS-Elements Software*Two Fully Parallel TCSPC FLIM Channels*Compact bh Simple-Tau or Power-Tau System*Two HPM-100-40 GaAsP Hybrid Detectors*Excitation by bh ps Diode Lasers*Excellent Time Resolution: Electrical IRF Width 6.5 ps FWHM*Excellent Timing Stability*Time Channel Width Down to 813 fs*Megapixel FLIM, Up to 2048 x 2048 Pixels at 256 Time Channels*Detection Wavelength Range from 360 nm to 700 nm
-
FV1000 - Becker & Hickl GmbH
*Two Fully Parallel TCSPC FLIM Channels*Compact bh Simple-Tau or Power-Tau System*Two HPM-100-40 GaAsP Hybrid Detectors*Optional: HPM-100-06 Hybrid Detectors, IRF Width < 20 ps FWHM*Optional: HPM-100-50 Hybrid Detectors for NIR FLIM*Optional: Multi-Wavelength FLIM*Excitation by bh ps Diode Lasers*Excellent Time Resolution: Electrical IRF Width 6.5 ps FWHM*Time Channel Width Down to 813 fs*Megapixel FLIM, Up to 2048 x 2048 Pixels at 256 Time Channels*Simultaneous FLIM/PLIM*Detection Wavelength Range from 360 nm to 900 nm*Excitation by Ti:Sa Laser, OPO, or by bh ps Diode Lasers*Systems for Multiphoton FLIM and Confocal FLIM*Systems are Modular: More FLIM Channels can be Added
-
710 / 780 / 880 - Becker & Hickl GmbH
*Two Fully Parallel TCSPC FLIM Channels*Compact bh Simple-Tau or Power-Tau System*Two HPM-100-40 GaAsP Hybrid Detectors*Optional: HPM-100-06 Hybrid Detectors, IRF Width < 20 ps FWHM*Optional: HPM-100-50 Hybrid Detectors for NIR FLIM*Optional: Multi-Wavelength FLIM*Excellent Time Resolution: Electrical IRF Width 6.5 ps FWHM*Time Channel Width Down to 813 fs*Megapixel FLIM, Up to 2048 x 2048 Pixels at 256 Time Channels*Simultaneous FLIM/PLIM*Detection Wavelength Range from 360 nm to 900 nm*Excitation by Ti:Sa Laser, OPO, or by bh ps Diode Lasers*Identical Systems for Multiphoton FLIM and Confocal FLIM*Detectors can be Swapped Between NDD Port and Confocal Port*Systems are Modular: More FLIM Channels can be Added
-
Becker & Hickl GmbH
*Time / Point 250 ns to 100 000 s*Up to 64 k Points / Curve*800 MHz Saturated Count Rate*Gating Down to 1 ns*2 Detector Channels / Module*Free Instrument Software for Windows XP/Vista/7/10*Parallel Operation of Up to 4 Modules
-
HT-Series - Becker & Hickl GmbH
Dielectric Voltage Withstand Test or High Potential Test (HIPOT test) is a 100% production line test to verify the quality & electrical safety characteristics of products.
-
PMS - Becker & Hickl GmbH
*PMS Standard Software for Data Acquisition*Setting of Measurement Parameters*Control of Measurements for Up to 4 ModulesLoading and Saving of Measurement Data and Parameters*Display of Results as Curves or Bars
-
BDS-SM Series - Becker & Hickl GmbH
*Pulse Width Down to 60 ps*Repetition Rate 20 MHz /50 MHz / 80 MHz / CW (Switchable)*Free Beam or Fiber Output*All Electronics Integrated*No External Driver Unit*Simple +12 V Supply*40 mm x 70 mm x 120 mm
-
BDL-SMN Series - Becker & Hickl GmbH
*Pulse Width Down to 40 ps*Repetition Rate 20 MHz / 50 MHz / 80 MHz / CW (Switchable)*Free Beam Output or Single-Mode Fiber Coupling*Beam Profile Correction Optics*All Electronics Integrated*No External Driver Unit*Simple +12 V Supply*Fast On / Off / Multiplexing Capability*Synchronisation Input
-
BDS-MM Series - Becker & Hickl GmbH
*Pulse Width Down to 60 ps*Repetition Rate 20 MHz / 50 MHz*Free Beam or Fiber Output*Optical Power Up to 40 mW*All Electronics Integrated*No External Driver Unit*Simple +12 V Supply*40 mm x 70 mm x 120 mm
-
BDS-SMY Series - Becker & Hickl GmbH
*Pulse Width Down to 50 ps*Repetition Rate 50 MHz (20 MHz Available on Request)*Free Beam or Fiber Output*CW-Equivalent Power 0.3 mW to 0.5 mW*All Electronics Integrated*No External Driver Unit*Simple +12 V Supply*40 mm x 70 mm x 120 mm
-
DCS-120 MP - Becker & Hickl GmbH
*Multiphoton FLIM Upgrade for Existing Conventional Microscope*Two Fully Parallel TCSPC FLIM Channels*Compact bh Simple-Tau or Power-Tau System*Scanning by Fast Galvanometer Mirrors*Channel Seperation by Dichroic or Polarising Beamsplitters*Individually Selectable Pinholes and Filters*Excitation by Ti:Sa Laser*Two Non-Descanned Detection Channels*Two HPM-100-40 GaAsP Hybrid Detectors*Optional: Two HPM-100-06 Hybrid Detectors, IRF Width < 20 ps FWHM*Optional: HPM-100-50 Hybrid Detectors for NIR FLIM*Optional: Multi-Wavelength FLIM*Excellent Time Resolution: Electrical IRF Width 6.5 ps FWHM*Time Channel Width Down to 813 fs*Megapixel FLIM, Up to 2048 x 2048 Pixels at 256 Time Channels*Simultaneous FLIM/PLIM*Electronic Pinhole Alignment*Z-Stack FLIM Acquisition with Zeiss Axio Observer Z1*Optional: Spatial Mosaic FLIM via Motorized Sample Stage*Laser Control via SPCM Software