Showing results: 256 - 270 of 364 items found.
-
HVFO100-1X-TIP-U -
Teledyne LeCroy
- Ideal for GaN and SiC devices- Highest system accuracy- Fastest rise time- High CMRR - 160 dB
-
DL-ISO-2500V-TIP -
Teledyne LeCroy
- Ideal for GaN and SiC devices- Highest system accuracy- Fastest rise time- High CMRR - 160 dB
-
DL-ISO-1000V-TIP -
Teledyne LeCroy
- Ideal for GaN and SiC devices- Highest system accuracy- Fastest rise time- High CMRR - 160 dB
-
DL-ISO-200V-TIP -
Teledyne LeCroy
- Ideal for GaN and SiC devices- Highest system accuracy- Fastest rise time- High CMRR - 160 dB
-
DL-ISO-40V-TIP -
Teledyne LeCroy
- Ideal for GaN and SiC devices- Highest system accuracy- Fastest rise time- High CMRR - 160 dB
-
RP4030 -
Teledyne LeCroy
The Teledyne LeCroy RP4030 Power Rail Probe meets the specific requirements of those who need to acquire a low-voltage DC signal as part of a:-Comprehensive power integrity, digital power management IC (PMIC), voltage regulator module (VMR), point-of-load (POL) switching regulator, or low-dropout regulator testing- Complete embedded power management system that includes PMICs, VRMs, POLs, and LDOsThe RP4030 will faithfully acquire a low-impedance, low-voltage DC power/voltage rail signal without unduly loading the device under test (DUT), while providing high offset to allow DC power/voltage rail signal display on an oscilloscope with high gain.
-
ZS4000 -
Teledyne LeCroy
Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.6 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS4000 is ideal for 2.5 GHz and 4 GHz oscilloscopes.
-
ZS2500 -
Teledyne LeCroy
Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.9 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS2500 is ideal for 2.5 GHz and lower oscilloscopes.
-
ZS1500 -
Teledyne LeCroy
Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.9 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS1500 is ideal for 1 GHz and lower oscilloscopes.
-
ZS1000 -
Teledyne LeCroy
Engineers must commonly probe high frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. The ZS Series features both high input R (1 MΩ) and low input C (0.9 pF) to reduce circuit Loading across the entire probe/oscilloscope bandwidth. The ZS1000 is ideal for 200–600 MHz oscilloscopes.
-
Teledyne LeCroy
Voltage rail probes are designed specifically to probe a 50 Ohm DC power/voltage rail. The probe has large built-in offset, low attenuation (noise), and high DC input impedance. Built-in offset and low attenuation permit the power/voltage rail to be offset in the oscilloscope by its mean DC voltage with high oscilloscope gain (sensitivity) to achieve a noise-free view of small signal variations. The high DC input impedance eliminates loading of the DC rail.
-
PPE6KV-A -
Teledyne LeCroy
High voltage single-ended passive probes are suitable for a wide range of applications where ground-referenced high-voltage measurements must be made safely and accurately. There is also a sense pin to automatically configure the oscilloscope for use with the probe.
-
HVP120 -
Teledyne LeCroy
High voltage single-ended passive probes are suitable for a wide range of applications where ground-referenced high-voltage measurements must be made safely and accurately. There is also a sense pin to automatically configure the oscilloscope for use with the probe.
-
RP2060 -
Teledyne LeCroy
+/-60V offset permits the DC signal to be displayed in the vertical center of the oscilloscope grid with a high-sensitivity gain setting (maximum +/-800mV dynamic range).
-
PP019-1 -
Teledyne LeCroy
Passive probes are the standard probe provided with most oscilloscopes. Typical passive probes provide a 10:1 attenuation and feature a high input resistance of 10 MΩ. This high input resistance means that passive probes are the ideal tool for low frequency signals since circuit loading at these frequencies is minimized. Passive probes are designed to handle voltages of at least 400V, some as high as 600V. Teledyne LeCroy passive probes feature an attenuation sense pin which tells the oscilloscope to scale the waveforms automatically requiring no user input.Each passive probe is recommended for a certain oscilloscope, using the right passive probe with the right oscilloscope means that the probe will be properly compensated across the entire bandwidth. Using probes with a different oscilloscope will only let you compensate for low frequencies.