Teledyne Monitor Labs
Teledyne Monitor Labs (TML) has more than 50 year’s global experience in the design and manufacture of continuous emission monitoring systems (CEMS), process monitoring, industrial sensors and instruments, ambient monitoring and software. Our services and products serve the following industries: power generation, oil/gas refining, petrochemical, cement, lime, pulp and paper, steel, chemical, and agriculture.
- 1-800-422-1499
- GoTML@teledyne.com
- 35 Inverness Drive East
Englewood, Colorado 80112
United States of America
-
Product
Chemiluminescence Ammonia Analyzer
Model T201
-
The Model T201 combines a specially configured chemiluminescence analyzer with an external thermal converter to give stable and repeatable NH3 measurements at very low levels. In addition, the T201 provides simultaneous values for NO, NO2, and NOx concentrations. The T201 is ideal for trace ammonia monitoring applications in ambient air as well as in clean rooms and make-up air units. Optional zero and span valves allow automatic, unattended calibration checks.The Model T201 achieves its remarkable stability by means of an AutoZero valve which measures and corrects for zero noise. Multiple self-checks are performed continuously to insure maximum up-time while an innovative sample path, plumbed with specially conditioned materials, preserves the NH3 sample and reduces interferents to a minimum. All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports either locally or by remote connection.The Model T201 comes with the Numaview™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
Continuous Emission Monitoring Systems
-
TML has more than 50 years' experience designing, manufacturing, and supporting continuous emission monitoring systems (CEMS). We have a team of experienced CEMS air quality experts that will thoroughly review your process and operating permit and recommend the most cost effective and reliable solution for monitoring the gases of interest. TML's continuous emission monitoring systems are based on rugged, reliable equipment manufactured to exact standards. The result is products and systems with some of the highest mean time between failure rates in the industry. Whether it's a standard or custom solution, we stand behind our products 110%, guarantee CEMS certification, at least 95% uptime, replacement parts, and 24 x 7 support. We offer a total CEMS solution including data acquisition software for recordkeeping and reporting, lower cost of ownership, superior product reliability and designed for simple and easy maintenance.
-
Product
Total Hydrocarbon THC/VOC Monitoring System
ML661
-
The Teledyne ML®661 is a complete engineered CEMS designed to measure total hydrocarbons (THC/VOC) as required in environmental regulatory compliance and process control applications. Please consult our factory for more information on this product.
-
Product
Chemiluminescence Oxides of Nitrogen Analyzer
Model T200
-
The Model T200 NO/NO2/NOx analyzer uses the proven chemiluminescence detection principle, coupled with state-of-the-art electronics to allow accurate and dependable low level measurements for use as an ambient analyzer or dilution CEMS monitor.A unique AutoZero feature provides superb stability by continuously correcting for zero drift, while advanced Adaptive Filtering allows the analyzer to optimize performance under changing conditions. The Model T200 includes a permeation inlet dryer for ozone generation to provide excellent reliability with no periodic replacement required. A catalytic exhaust ozone scrubber is standard for maximum safety and pump life.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T200 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
Mid-Range Gas Filter Correlation Carbon Monoxide Analyzer
Model T300M
-
The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.The energy loss through the sample cell is compared with the span reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance from low to high range.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T300M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
UV Fluorescence Total Reduced Sulfur Analyzer
Model T102
-
The Model T102 TRS analyzer uses the proven UV fluorescence principle to measure Total Reduced Sulfur at levels commonly required for ambient air monitoring.The Model T102 uses a high temperature external converter set at 850°C to allow conversion of H2S, methyl mercaptan, dimethyldisulfide, and methyl-disulfide to SO2 at this temperature with efficiency greater than 98%. A switching option alternately measures TRS and SO2 while showing both readings concurrently on the front display.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T102 comes with NumaView ™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView ™ Software.
-
Product
Mid-Range Chemiluminescence Oxides of Nitrogen Analyzer
Model T200M
-
The Model T200M combines the proven chemiluminescence principle with a number of innovative features to provide reliable and repeatable NO, NO2, and NOx measurements for extractive type CEM systems. The option of either a molybdenum converter or a high-efficiency stainless steel thermal NO2 converter allows the T200M to be used in a variety of extractive CEM systems, from gas turbines to coal-fired boilers. The T200M may be fitted with an optional, internal paramagnetic O2 sensor or an infrared absorption CO2 sensor, reducing integration and operating costs significantly.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T200M comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
Ambient Air Quality Monitoring Systems (AAQMS)
-
TML's low level air quality monitoring systems are custom designed to meet our customer's ambient air monitoring requirements.
-
Product
Gas Filter Correlation Carbon Dioxide Analyzer
Model T360
-
The Model T360 CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range.All T Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O, and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel, or via RS232, Ethernet, or USB com ports, either locally or by remote connection.The Model T360 comes with NumaView™ Software. NumaView™ Remote PC Software allows for a remote connection with virtual interface and data downloading capability to analyzers operating NumaView™ Software.
-
Product
Dilution-Extractive System
ML675
-
The Teledyne ML®675 dilution-extractive system can be used in 40CFR75, 40CFR60, 40CFR63, and process control applications. In this system, sample is prepared for analysis by diluting stack gas with clean, dry instrument air at the probe location. Since no moisture is removed with dilution, measurements for SO2, NOx, CO, THC and CO2 are made on a wet basis.
































































