LXinstruments GmbH
The LX instruments GmbH was originally founded in 2006 as a solution provider for all questions relating to instruments and systems of electronic measurement technology. Schwerpunktmäßg our systems are based on the LXI Standard (LAN based Extensions for Instrumentation), an open industry standard.
- +49 (0) 7032 / 895 93-0
- +49 (0) 7032 / 895 93-18
- info@lxinstruments.com
- Rudolf-Diesel-Str. 36
Nufringen, 71154
Germany
-
Product
Isolated D/A Converter 8 Channel, 250kSa/s
OTP2 module no.187
-
The PXIe‑4322 is a channel-isolated analog output module with built-in signal conditioning. The module provides accurate, simultaneous dynamic voltage and current outputs. By combining signal conditioning and D/A converters in one device, the PXIe‑4322 isolated analog output module offers smaller dimensions and higher measurement performance. In current mode, the module operates in all four quadrants, allowing current to be drawn and sourced. Thanks to isolation and outputs for higher voltages and currents, the module is particularly suitable for applications in the automotive sector.
-
Product
Rack - Rotatable Arm for Peripheral Devices
OTP2-Modul-Nr041
-
The module is for mounting on a rack, such as the midi or maxi rack. The extension of the module can create new possibilities for your test system.
-
Product
Intelligent Charging Cable: Test Strategy and Test Execution
-
The ICCB takes over the safety and control functions that are otherwise integrated in the stationary charging station. This places increased demands on the function test in production.
-
Product
PCIe Card MX3 Copper Interface
OTP2 module no.183
-
PXI offers the optimal approach to validation and production testing. You can meet timing, synchronization, and throughput requirements across devices. PXI is a robust PC-based platform for measurement and automation systems, supported by software. PXI combines PCI electrical bus characteristics with CompactPCI's modular Eurocard packaging, and then adds special synchronization buses and important software functions.
-
Product
2-in-1 High-Voltage Test Hood
LX-HVE900EC
-
The test cells are made of stable, highly insulating plastic and are closed by a swiveling, transparent cover. The built-in safety switch is used to lock the hood and release the high-voltage sources. This ensures that no high voltage is active when the door is open. There is a generously dimensioned wiring space in the floor of the test cage. An interchangeable adapter plate in the test cell - optionally with an interchangeable interface or an interchangeable adapter cassette - allows quick adaptation to different types of test items. Prepared openings enable connectors and other common interfaces or cable bushings to be easily attached. The hood is opened and closed almost effortlessly thanks to precisely coordinated gas springs.
-
Product
Grid Simulators
Simulator
A grid simulator can be used to simulate the characteristics of low-voltage mains. For this purpose, all voltages and frequencies of the supply networks occurring worldwide can be simulated. Critical states such as short-term voltage dips or voltage peaks (surge/burst) can also be generated.The integrated sequencer function enables the generation of different network parameters, e.g. distorted waveforms and intermediate oscillations. Therefore, grid simulators are well suited for testing conformity to standards and especially for determining the behaviour of electrical equipment in borderline situations. Many European and other international standards are pre-programmed for testing.
-
Product
Repair
-
There might be various reasons why you run into trouble with your test system and need support. No matter if your test system is not operating any more, if the forklift damaged it or you pressed a wrong button during the software-update - we are at your disposal to help. Usually the self test of the system helps further or if you agree we can help on a remote basis.If this does not help we deliver as soon as possible spare parts or send a repairperson. Our suppliers all offer support, delivery or even subsidiaries wordwide. This enables our technician to bring the spare part either with him or to send the exchange device directly to your place.
-
Product
Fixture Interface Module 2 Test Matrices
OTP2 module no.193
Interface Module
PXI offers the optimal approach to validation and production testing. You can meet timing, synchronization, and throughput requirements across devices. PXI is a robust PC-based platform for measurement and automation systems, supported by software. PXI combines PCI electrical bus characteristics with CompactPCI's modular Eurocard packaging, and then adds special synchronization buses and important software functions. PXI is both a powerful and cost-effective platform for applications such as manufacturing test, military, aerospace, machine monitoring, automotive, and industrial test.
-
Product
DUT Matrix 32 DUT Matrix Channels
40-530-021
-
The 40-530-021 is a high density 32x8 1 pole reed relay matrix. Typical applications are signal routing in functional ATE and data acquisition systems. It consists of highly reliable sputtered ruthenium reed relays that offer >10e9 switching cycles to ensure maximum switching reliability with a long service life and stable contact resistance. Larger arrays can be built by daisy-chaining the common signals from multiple PXI modules
-
Product
Industrial Automation Solutions
-
LXinstruments FCT systems for industrial electronics assemblies are particularly suited for applications with a large variant diversity for medium volume sizes. They are used for testing utility electronics as well as for drive control and grid management systems. We have also implemented systems for functional test, repair and calibration of decentralized PLC I/O assemblies.Since early failures in the field often lead to enormous costs, we not only provide functional test systems, but also burn-in systems for simultaneous testing of many assemblies in a climate chamber. Due to the modular structure of our software, it is possible to establish a logical separation between the definition of the climatic profile to be executed and the actual test sequence, during which the different electrical tests are processed. Connections to HALT/HASS systems can also be established without problems.