Teledyne Advanced Pollution Instrumentation
Teledyne API (TAPI) designs and builds precision air quality and industrial gas monitoring instrumentation at our factory located in San Diego, California, USA. Our products are used worldwide in ambient air quality monitoring systems (AQMS), continuous emissions monitoring systems (CEMS), and industrial process applications.
- (858) 657-9800
- (858) 657-9818
- api-sales@teledyne.com
- 9970 Carroll Canyon Road
CA, San Diego 92131
United States of America
Categories
-
product
Particulate Instruments
Teledyne Advanced Pollution Instrumentation
Teledyne API offers a combination of particulate matter measurements to meet a variety of data quality objectives for regulatory ambient air quality monitoring. All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support.
-
product
THC-CH4-NMHC Analyzer
Model N901
Teledyne Advanced Pollution Instrumentation
The Model N901 is a near-continuous hydrocarbon gas analyzer that measures the concentration of Methane (CH4) and Total Hydrocarbons (THC) in air. The concentration of the non-Methane (NMHC) component is calculated by the subtraction of CH4 from THC, with high sensitivity and accuracy. The hydrocarbons are measured using a Flame Ionization Detector (FID), in combination with gas chromatography (GC). The instruments range and performance are tuned specifically for use in ambient air quality monitoring assessments.
-
product
Trace Level Chemiluminescence NO-NOy Analyzer
Model T200U NOY
Teledyne Advanced Pollution Instrumentation
The Model T200U NOy analyzer has been developed and refined specifically to address the challenges of NOy monitoring as required, for example, in the US NCore network. It uses the proven chemiluminescence principle and is coupled with a remote NOy converter via umbilical to allow measurements with a lower detectable limit of 50 ppt.The Model T200U NOy analyzer combines a gold plated reaction cell with an enhanced performance pump, special low noise photomultiplier tube, and unique signal conditioning to provide exceptional sensitivity. In addition, a pre-reactor separates the NO-O3 reaction from background chemiluminescence to allow accurate auto-zero of the analyzer. The remote NOy converter is provided with a stainless steel, NEMA 4X (IP65) enclosure and custom sample umbilical to allow a mounting height of 10 meters. In addition, the converter features a unique purge circuit designed to remove residual calibration gas.
-
product
Gas Measuring Instruments
N Series
Teledyne Advanced Pollution Instrumentation
N Series Gas Measuring Units for SO2 (Sulfur Dioxide), NO, NO2, NOX (Nitrogen Oxide, Nitrogen Dioxide), CO (Carbon Monoxide), CO2 (Carbon Dioxide), O3 (Ozone), True, Direct NO2, NOX, NO, CH4 (Methane), THC (Total Hydrocarbons), and more
-
product
PM Mass Monitor
Model T640
Teledyne Advanced Pollution Instrumentation
The Model T640 PM Mass Monitor is the next breakthrough in ambient particulate monitors. The T640 delivers 1-min or better time resolution with exceptional sensitivity and precision. The instrument is very low maintenance and requires no sample media for minimal cost of operation.
-
product
Trace Level Portable Gas Calibrator
Model T750U
Teledyne Advanced Pollution Instrumentation
The Model T750U is a portable, microprocessor based calibrator for precision trace-level gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero calibrations. The T750U is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field.
-
product
Mid-Range Gas Filter Correlation CO2 Analyzer
Model T360M
Teledyne Advanced Pollution Instrumentation
The Model T360M CO2 analyzer measures Carbon Dioxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO2 filled chamber and a chamber with no CO2 present. The light path then travels through the sample cell, which has a folded path of 1.28 meters.The energy loss through the sample cell is compared with the reference signal provided by the filter wheel to produce a signal proportional to concentration, with little effect from interfering gases within the sample. This design produces excellent zero and span stability and high signal to noise ratio, allowing excellent performance over a wide concentration range, making this instrument an ideal choice for CO2 reporting requirements associated with dilution CEMS.
-
product
Portable Trace-Level O3 Calibrator
Model T753U
Teledyne Advanced Pollution Instrumentation
The Model T753U is a portable, microprocessor based precision Calibrator for Ozone gas instruments and sensors. Using a sophisticated Ozone generation system, combined with a sensitive photometer and pneumatic design, the T753U produces stable and reliable concentrations of Ozone in a convenient and rugged package based on our popular T750U Portable Multigas Calibrator platform. The T753U is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field for virtually any application. An internal zero air option extends the T753U's capabilities to also provide a clean and dry source of zero air, eliminating the need for a separate source of zero air. The internal zero air source module contains a software driven electronic inlet valve manifold allowing the calibrator to automatically switch between internal and external zero air sources depending on the application needs.
-
product
Chemiluminescence NOX-NO2-NO Analyzer
Model N200
Teledyne Advanced Pollution Instrumentation
The Model N200 uses the proven chemiluminescence detection principle, combined with a state-of-the-art modular architecture, and intuitive operating software to provide accurate and dependable measurements of low-level Nitric Oxide (NO), Nitrogen Dioxide (NO2) and total Nitrogen Oxides (NOx) gases.
-
product
Trace-Level UV Fluorescence SO2 Analyzer
Model T100U
Teledyne Advanced Pollution Instrumentation
The Model T100U Trace-level SO2 analyzer has been developed specifically to address the challenges of low level monitoring as required, for example, in the US NCore network. It uses the proven UV fluorescence principle, and is designed to allow ultra-sensitive SO2 measurements while still meeting the requirements for use as a US EPA compliance analyzer.The analyzer uses both the light and dark phases of the pulsed UV light source to continuously detect and correct for electronic noise, giving exceptionally stable and sensitive performance. A separate UV detector allows the instrument to continuously correct for variations in lamp intensity. Exceptional stability is achieved with the use of an optical shutter to compensate for PMT drift, and a reference detector to correct for changes in UV lamp intensity. A hydrocarbon "kicker" and advanced optical design combine to prevent inaccuracies due to interferents.
-
product
Photolytic True NO2/NO/NOx Analyzer
Model T200P
Teledyne Advanced Pollution Instrumentation
The Model T200P provides measurements of NO and NO2 using our Model T200 NOx analyzer combined with a patented high efficiency photolytic converter. Even low temperature molybdenum converters transform other nitrogen-containing compounds such as HNO3, PAN, etc. to a considerable extent. Simultaneous measurements of NO2 performed with molybdenum and photolytic converters have shown significantly different results in the presence of such compounds.In the photolytic process the sample gas passes through a cell where it is exposed to light at a specific wavelength from an LED array. This causes the NO2 to be selectively converted to NO with negligible interference from other gases. Advances in the photolytic converter technology now yields NO2 conversion efficiency that is similar to molybdenum under typical ambient NO2 concentrations, but without the same interferences.
-
product
Gas Filter Correlation CO2 Analyzer
Model N360
Teledyne Advanced Pollution Instrumentation
The Model N360 measures carbon dioxide (CO2) by comparing infrared energy absorbed by a sample to that absorbed by a reference according to the Beer-Lambert law.The N360 uses Gas Filter Correlation (GFC) to overcome the interfering effects of various other gases (such as water vapor) that also absorb IR. The analyzer passes the IR beam through a spinning wheel made up of two separate chambers: one containing a high concentration of CO2 known as the reference, and the other containing a neutral gas known as the measure. The concentration of CO2 in the sample chamber is computed by taking the ratio of the instantaneous measure and reference values and then compensating the ratio for sample temperature and pressure. A nitrogen purge system is provided for the GFC wheel assembly to eliminate the effects of ambient CO2, if necessary.
-
product
CAPS True NO2-NOX-NO Analyzer
Model N500
Teledyne Advanced Pollution Instrumentation
The Model N500 CAPS NOx analyzer uses superior Cavity Attenuated Phase Shift (CAPS) Spectroscopy to measure True NO2, NOx, and NO gases. The instrument combines direct NO2 measurements with highly efficient gas phase titration (GPT) to convert and measure the NO gas component. An automatic baseline reference cycle accounts and compensates for any potential baseline drift due to varying environmental conditions.
-
product
Mid-Range Gas Filter Correlation CO Analyzer
Model T300M
Teledyne Advanced Pollution Instrumentation
The Model T300M CO analyzer measures low to mid ranges of carbon monoxide by comparing infrared energy absorbed by a sample to that absorbed by a reference gas according to the Beer-Lambert law. Using a Gas Filter Correlation Wheel, a high-energy IR light source is alternately passed through a CO filled chamber and a chamber with no CO present. The light path then travels through the sample cell, which has a folded path of 2.56 meters.
-
product
Portable Gas Calibrator
Model T750
Teledyne Advanced Pollution Instrumentation
The Model T750 is a portable, microprocessor based calibrator for precision gas analyzers. Using highly accurate mass flow controllers combined with compressed sources of standard gases, calibration standards are provided for multipoint span and zero calibrations. The T750 is housed in a high-density, molded travel case which includes an integral handle and wheels for durability and ease of use in the field.The Model T750 can be equipped with an optional UV ozone generator for accurate, dependable ozone calibrations, and production of NO2 when blended with NO gas in the included, internal gas phase titration (GPT) chamber. An optional photometer allows even more precise control of the ozone generator giving accurate and dependable ozone calibrations and enhanced GPT. A number of calibration sequences may be programmed into the non-volatile memory of the Model T750, covering time periods up to a year.