Showing results: 16 - 30 of 104 items found.
-
Model 4030 -
Teledyne Analytical Instruments
The Model 4030 uses a field proven FID detector in a heated chamber. The chamber is heated to a high temperature to meet US EPA requirements for VOC emissions monitoring.
-
Model 4040 -
Teledyne Analytical Instruments
The Model 4040 is a microprocessor-based, oven heated methane/non-methane gas analyzer designed to measure varieties of hydrocarbon concentrations from a sampling point.
-
-
-
Model 8800A -
Teledyne Analytical Instruments
The 8800 series uses field proven aluminum oxide (Al2O3) sensing technology to accurately detect trace moisture on either a continuous or spot checking basis. All Al2O3 sensors share the same basic operating principle: the capacitance measured between the sensor’s aluminum core and gold film deposited on the oxide layer varies with the water content. The 8800 series moisture sensor employs unique Hyper Thin Film (HTF) technology, which offers three major structural improvements in Al2O3 sensor design. These structural changes, noted below, provide the user with increased sensitivity, greater stability and a quicker response time when compared to other conventional aluminum oxide sensors on the market today.
-
Model GFC-7000T -
Teledyne Analytical Instruments
The GFC Series gas filter correlation analyzers measure low ranges of gases (CO2, CO2 and N2O detecting models available by comparing infrared energy absorbed by a sample to that absorbed by a reference according to Beer-Lambert Law. All GFC Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel or via RS-232, Ethernet or USBcom ports either locally or by remote connection using the included APIcom™ software.
-
Model GFC-7002T -
Teledyne Analytical Instruments
The GFC Series gas filter correlation analyzers measure low ranges of gases (CO, CO2 and N2O detecting models available by comparing infrared energy absorbed by a sample to that absorbed by a reference according to Beer-Lambert Law. All GFC Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel or via RS-232, Ethernet or USBcom ports either locally or by remote connection using the included APIcom™ software.
-
Model GFC-7001T -
Teledyne Analytical Instruments
The GFC Series gas filter correlation analyzers measure low ranges of gases (CO2, CO2 and N2O detecting models available by comparing infrared energy absorbed by a sample to that absorbed by a reference according to Beer-Lambert Law. All GFC Series instruments offer an advanced color display, capacitive touch screen, intuitive user interface, flexible I/O and built-in data acquisition capability. All instrument set up, control and access to stored data and diagnostic information is available through the front panel or via RS-232, Ethernet or USBcom ports either locally or by remote connection using the included APIcom™ software.
-
Model 7500ZA -
Teledyne Analytical Instruments
The 7500Z and 7600Z Series Infrared (IR) Analyzers are capable of detecting up to four chosen, individual IR absorbing components (i.e. CO, CO2, CH4, SO2, NO or NOX with external converter) on a continuous basis. Conveniently packaged in a 19” rack mount, the analyzer can also be supplied with an oxygen sensor, providing the operator with space saving, five in one, cost-effective design. The NEMA-4 enclosure can be purged to meet Class I, Div 1 (Zone 1) or Class I, Div 2 (Zone 2) hazardous area installation requirements.
-
Model 7600ZA -
Teledyne Analytical Instruments
The 7500Z and 7600Z Series Infrared (IR) Analyzers are capable of detecting up to four chosen, individual IR absorbing components (i.e. CO, CO2, CH4, SO2, NO or NOX with external converter) on a continuous basis. Conveniently packaged in a 19” rack mount, the analyzer can also be supplied with an oxygen sensor, providing the operator with space saving, five in one, cost-effective design. The NEMA-4 enclosure can be purged to meet Class I, Div 1 (Zone 1) or Class I, Div 2 (Zone 2) hazardous area installation requirements.
-
-
-
Model 8800P -
Teledyne Analytical Instruments
The 8800 series uses field proven aluminum oxide (Al2O3) sensing technology to accurately detect trace moisture on either a continuous or spot checking basis. All Al2O3 sensors share the same basic operating principle: the capacitance measured between the sensor’s aluminum core and gold film deposited on the oxide layer varies with the water content. The 8800 series moisture sensor employs unique Hyper Thin Film (HTF) technology, which offers three major structural improvements in Al2O3 sensor design. These structural changes, noted below, provide the user with increased sensitivity, greater stability and a quicker response time when compared to other conventional aluminum oxide sensors on the market today.
-
Model 8800T -
Teledyne Analytical Instruments
The 8800 series uses field proven aluminum oxide (Al2O3) sensing technology to accurately detect trace moisture on either a continuous or spot checking basis. All Al2O3 sensors share the same basic operating principle: the capacitance measured between the sensor’s aluminum core and gold film deposited on the oxide layer varies with the water content. The 8800 series moisture sensor employs unique Hyper Thin Film (HTF) technology, which offers three major structural improvements in Al2O3 sensor design. These structural changes, noted below, provide the user with increased sensitivity, greater stability and a quicker response time when compared to other conventional aluminum oxide sensors on the market today.
-
Model 8800B -
Teledyne Analytical Instruments
The 8800 series uses field proven aluminum oxide (Al2O3) sensing technology to accurately detect trace moisture on either a continuous or spot checking basis. All Al2O3 sensors share the same basic operating principle: the capacitance measured between the sensor’s aluminum core and gold film deposited on the oxide layer varies with the water content. The 8800 series moisture sensor employs unique Hyper Thin Film (HTF) technology, which offers three major structural improvements in Al2O3 sensor design. These structural changes, noted below, provide the user with increased sensitivity, greater stability and a quicker response time when compared to other conventional aluminum oxide sensors on the market today.