  • Signal Chain µModule Receivers

    µModule® - Analog Devices Inc.

    Analog Devices µModule® (micromodule) receivers consist of high performance, high speed ADCs with fixed-gain, high speed amplifiers and antialias filters. Our integrated ADC and driver products include integrated bypass capacitance and simplify the high frequency layout required to preserve ac performance. The board space savings are significant for instrumentation applications such as spectrum analyzers, oscilloscopes ,and communications test equipment, or for communications applications such as high sensitivity receivers, software-defined radio (SDR), or signal intelligence receivers. Our portfolio uses system-in-package (SiP) technology similar to multichip modules (MCM) to integrate components with different technologies, along with passive components to make an integrated subsystem.

  • Advanced Test Platforms

    980 Series - Teledyne LeCroy quantumdata

    The Teledyne LeCroy quantumdata 980 series Advanced Test Platforms are module based systems that can accommodate multiple 980 series modules. There are two (2) 980 platforms available. The 980 series platforms and associated modules can be controlled either through the PC-based 980 GUI Manager or through the embedded 980 GUI Manager running on the 980B or 980R platforms’ built-in color touch screen. The 980 GUI Manager provides a graphical user interface (GUI) to control the instrument and view status. The embedded GUI Manager enables you to view incoming video and metadata in the Real Time mode when using any of the 980 modules with an analyzer function.

  • MMW Field Sensors

    ITS-9050 - Innovative Technical Systems

    The Innovative Technical Systems ITS-9050 Detector is a sensitive, harmonic mixing detector designed to measure millimeter-wave free-space radiation. It is ideal for measuring radiation patterns of antennas inboth the near and far-field. The ITS-9050 employs a free-running dielectric resonator oscillator (DRO) and an integrated harmonic mixer with a waveguide RF input that either connects directly to a circuit under test or to an antenna for radiation detection. The resulting IF is amplified and detected by an IF log-detector that drives a front panel LCD voltmeter to provide an indication of signal strength. A DC output voltage from the log detector is available on a BNC connector to drive external data acquisition instrumentation. Also, a sample of the IF output is provided for measurement on a spectrum analyzer.

  • Stream & Video Quality Analysis System

    VQTS-300 - VideoQ Inc

    VQTS-300 is a self-contained solution, combining: HDMI/DVI, Display Port or LVDS grabber - one of Unigraf UFG-04 range capture cards, order option Powerful stream analysis tools - Unigraf UFG-04 software Sophisticated image quality analyzer - VideoQ VQMA3 software Ideal tool for development labs, software developers and high volume manufacturers Easy-to-use tool, instantly revealing your source-sink link status, video camera or other video device performance User-selectable reporting modes: machine-readable file with Pass/Fail marks detailed multi-page PDF document Manual and automated performance measurement of HDM/DPI links, video cameras and/or video processors Via optional SDI-HDMI adapter VQTS-300 measures the performance of 3G-SDI/HD-SDI video processors

  • Engine Emission Test System

    Ono Sokki

    By adding transient operation functions (self-learning/predictive driving + each test mode performing) to measurement•control panel, Ono Sokki can build up engine test system that can perform transient mode tests supporting worldwide gas emission controls including TRIAS, FTP, EURO, and ISO. (e.g. WHDC, NRTC).This system provides good reproducibility for Transient mode test. Delay compensation and rotation inertia compensation function have greatly improved as well as self-learning / predictive driving function.Automatically processes from measurement to data output of test result, in conjunction with gas emission analyzer, tunnels, gas emission particle measurement system, smoke meter, etc.

  • RF Ports Alignment Software

    Rohde & Schwarz GmbH & Co. KG

    With the R&S®RF Ports Alignment software together with the option R&S®SMW-K545, Rohde & Schwarz provides a standard and tailored solution for calibrating amplitude, time and phase of multi-channel SMW setups. The RF Port Alignment automatically collects the gathered correction data for the multi-channel setup using a connected vector network analyzer such as the R&S®ZNA or R&S®ZNB. Thanks to an intuitive graphical user interface the test engineer is guided through the calibration procedure step-by-step in a convenient way. With a calibrated multi-channel setup, tests of advanced systems in wireless communication or of radar receivers can be performed straightforward.

  • Precision DC Power Module, 20V, 50A, 500W

    N6765A - Keysight Technologies

    The Keysight N6765A is a 500 W precision DC power module that provides low noise, and precise control and measurements in the milliampere and microampere region with the ability to simultaneously digitize voltage and current, and capture those measurements in an oscilloscope-like data buffer. This module is used in both the small, multiple output 1U high N6700 Low-Profile Modular Power System (for ATE systems) and the multiple output N6705 DC Power Analyzer (for bench testing). GPIB, LAN, USB and LXI compliance are standard. Select from more than 30 different DC power modules ranging in capability from basic to high precision, and in power from 20-500 Watts.

  • PXIe-2541, 300 MHz, 8x12 PXI RF Matrix Switch Module

    780587-41 - NI

    PXIe, 300 MHz, 8x12 PXI RF Matrix Switch Module—The PXIe‑2541 is an RF signal switching matrix. With its non-blocking design, you can simultaneously connect any row or column within the switching matrix and maximize the flexibility of your test system. Isolation relays on the module disconnect unused parts of the switching matrix to maintain RF performance and high isolation. The density and bandwidth of the PXIe‑2541 is ideal for routing signals between digitizers, function generators, and other RF generators and analyzers. For higher channel count applications, you can connect multiple PXIe‑2541 modules together to create switching matrices of 8x24, 8x36, and larger.

  • PXI-2541, 300 MHz, 8x12 PXI RF Matrix Switch Module

    778572-41 - NI

    300 MHz, 8x12 PXI RF Matrix Switch Module—The PXI‑2541 is an RF signal switching matrix. With its non-blocking design, you can simultaneously connect any row or column within the switching matrix and maximize the flexibility of your test system. Isolation relays on the module disconnect unused parts of the switching matrix to maintain RF performance and high isolation. The density and bandwidth of the PXI‑2541 is ideal for routing signals between digitizers, function generators, and other RF generators and analyzers. For higher channel count applications, you can connect multiple PXI‑2541 modules together to create switching matrices of 8x24, 8x36, and larger.

  • Spectrum Analysis For E5081A Up To 44 GHz

    S960907B - Keysight Technologies

    The Keysight S960907B spectrum analyzer (SA) software application adds high-performance microwave spectrum analysis capabilities to the Keysight ENA-X up to 44 GHz. With fast stepped-FFT sweeps resulting from optimized data processing, the SA application provides quick spurious searches over broad frequency ranges. Conduct simultaneous spectrum measurements using test and reference receivers. For efficient measurements of spurious signals emanating from mixers and frequency converters, combine the multi-channel SA with the internal swept-signal generators. The SA application employs source-power and receiver-response calibration as well as fixture de-embedding, providing in-fixture and on-wafer spectrum measurements with the highest level of accuracy.

  • Scanner Probe

    RFS set - Langer EMV-Technik GmbH

    The RFS set consits of three passive near field probes designed for the use in a measurement scanner during the development of E-field and magnetic field. They are designed for frequency ranges of 30 MHz to 3 GHz. The probe heads of the RFS set allow for close measurements needed to correctly localize interference sources on an electronic assembly. They document the whole image of the device under test`s near field. The scanner probes have a sheath current attenuation and are electrically shielded. They are connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance. The measuring signal can be increased with PA 203 or PA 303 preamplifier. On request RFS, LFS and XFS scanner probes can be produced.

  • Near Field Probes 30 MHz up to 3 GHz

    RF1 set - Langer EMV-Technik GmbH

    The RF1 near field probe set consists of 4 passive near field probes for making measurements in the development phase of E-field and magnetic field in the ranges of 30 MHz to 3 GHz on electronic assemblies. The probe heads of the RF1 set allow for measurements close to the electronic assemblies, e.g. on single IC pins, conducting paths, components and their connectors in order to localize interference sources. Field orientation and field distribution on an electronic assembly can be detected through a trained special use of the near field probe. The near field probes are small and handy. They have a sheath current attenuation and are electrically shielded. They can be connected to a spectrum analyzer or an oscilloscope with a 50 Ω input. They do not have an internal terminating resistance.

  • Electronic Load

    Fideris

    * Fully programmable, self-contained, air-cooled solid state load.* Patented design is optimized to provide ultra-low impedance operation for fuel cell testing.* Load is compatible with AC impedance or frequency response analyzers.* Interchangeable shunts for precise operation over a wide dynamic range.* Ten built-in cell voltage monitoring inputs optional. Additional voltage monitoring inputs available.* Ethernet Interface for simple configuration and expansion!* Combine with additional Fideris™ Innovator Series™ modules to create a fully-integrated,fully-automated, customized test system.* System-wide control of all Fideris™ Test System Components using FCPower™ Software,LabviewTM, or other programming language.* Integrated hardwired Run/Standby signal.

  • Micro probes 1 MHz up to 6 GHz

    MFA 01 set - Langer EMV-Technik GmbH

    The micro probes are used to measure magnetic fields and they have a high resolution. They measure magnetic fields up to 6 GHz, e.g. at signal conductors (150µm), SMD components (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the Bias tee BT 706. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee BT 706 to a spectrum analyzer or an oscilloscope. Langer EMV-Technik GmbH includes correction lines in the delivery. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.

  • Micro probes 1 MHz up to 1 GHz

    MFA 02 set - Langer EMV-Technik GmbH

    The two in the set included micro probes are used to measure low-frequency magnetic fields up to 1 GHz, e.g. at signal conductors (150µm), SMD componets (0603-0201) or IC pins. The MFA micro probes are guided by hand. An amplifier stage is integrated into the probe head. The amplifier stage (9V, 100mA) is powered via the BT 706 Bias tee. It has an impedance of 50 Ohm. The micro probes are connected via the Bias tee to a spectrum analyzer or an oscilloscope. The MFA 02 set delivery of Langer EMV-Technik GmbH includes correction lines. With the help of the correction lines the probe output voltage is converted either into the respective magnetic field or to the current which is running through the conductor.