Filter Results By:

Products

Applications

Manufacturers

Sound

tympanum, bioacoustic sensed pressure waves.

See Also: Ultrasound, Audio, Infrasound, Reverberation, Acoustic, Sound Calibration


Showing recent results 76 - 90 of 605 products found.

  • Sound Level Meter

    831-LOWN - Larson Davis, Inc.

    Easily make low noise measurements to 6.5 dB A-weighted using the Model 831-LOWN sound level meter paired with the 378A04 low noise microphone and preamplifier. Due to the innovative design of the 378A04 which uses a prepolarized microphone and ICP (constant current) interface, the combination produces a highly portable system that is battery powered and intuitive to use for measuring low noise levels.

  • Sound Level Meter

    831C SoundAdvisor - Larson Davis, Inc.

    The SoundAdvisor Model 831C Sound Level Meter is designed to make noise measurement easy. Due to its color display, connectivity, extensive software features and small form factor the SoundAdvisor is an ideal choice for handheld operation. Attended measurements are simplified, with the ability to control and monitor data via any PC or mobile device with a standard web interface. Designed with the acoustic professional in mind, the SoundAdvisor offers an elegant solution for complex needs in an easy to use system.

  • Sound Level Calibrator

    521 - ACO Pacific, Inc.

    Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.

  • Sound Level Calibrator

    511E - ACO Pacific, Inc.

    Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.

  • Sound level meter

    01dB

    FUSION, the new sound level meter and analyzer from 01dB, is simply unique. With its compact, robust and practical design, FUSION is ideal for use in the field. FUSION offers an innovative solution for noise and vibration measurement, with high-performance features designed to facilitate analysis. It offers excellent connectivity, enabling you to manage your measurement sessions and optimize your operations remotely. With an IEC 61672 class 1 certification, FUSION guarantees flawless metrological quality in every situation.

  • Sound Level Meter

    SoundExpert LxT - Larson Davis, Inc.

    The Larson Davis SoundExpert LxT Sound Level Meter is a full-featured meter designed for general product evaluation and noise monitoring applications. SoundExpert LxT comes with a graphic display and a fixed set of firmware options applicable for these applications. It is available as a general hand-held meter or data acquisition tool and also in a short-term noise monitoring kit. The meter expands upon the Larson Davis tradition of delivering value, innovation and function in a rugged, single-handed package, and is backed by our 2-year factory warranty, 24-hour application support, and accredited factory service/calibration.

  • Sound Level Meters

    Dalian Taijia Technology Co.,Ltd

    Display: 10mm (0.4″) LCD (Liquid Crystal Display)● Function: LP , Leq ,LN.● Frequency range: 31.5Hz~8kHz● Measurement range: LP:30~130dB (A) 35~130dB (C) 35~130 dB (F) Leq :30-130dB LN .: 0-100%● Resolution: 0.1 dB● Accarcy:1dB● Memory: Maximum value (30groups)● Indicator: Low battery indicator● Alarm: electron● Connector:RS232C● Power supply: 4x1.5v AAA (UM-4 battery● Size: 236 x 63 x26 mm● Weight: 170g (including batteries)● Standed delivery:1.Main Unit................1pc2.Carrying Case............1pc.3.Operation Manual.........1pc.● Optional Accessories:1.ND9 sound level meter calibrator2.RS-232 and software3.External rela4.Bluetooth interface

  • Sound Level Calibrator

    TM 100 - KUSAM-MECO

    • Standard : Confirms to IEC 942 Class 1.• Output Sound Level : 94dB and 114dB under reference.• Accuracy : ±0.3dB (20°C, 760 mm Hg)• Frequency of 1000 ± 0.1% Hz allows calibration with A / B / C or D weighting networks or linear.• Low Battery Indicator (LED).- Operating Temperature range : -10 ~ +50 C- Storage Temperature range : -40 ~ +65 C (with batteries removed).- Temperature Coefficient : 0 ~ 0.01 dB / C• Calibration of “1 and ½” ceramic microphones.• Altitude Effects : Approx. 0.1 dB decrease for each 2000 feet increase in altitude fromsea level to 12,000 feet elevation, or comparable atmospheric pressure change(approx. every 50 mm of Hg decrease).• Battery : Single 9V transistor Battery. (NEDA 1604)• Battery Life : Approx 100 hours.• Dimension : 48 x 48 x 138mm

  • Sound Level Meters

    MRC ltd.

    Acoustic Data These definitions are intended simply as an aid to understanding and for this reason, some are not strictly scientifically accurate. For correct formal definitions, consult IEC standards 60651, 60804, 60942, 61252 and IEC 61672: 2003 part 1.

  • Sound and Vibration Analysis

    Compact Analysis - HEAD acoustics GmbH

    Compact Analysis is an ArtemiS SUITE module which is focused on the basic functions and the ideal tool for tasks that only require a few clicks.

  • Impulsive Sound Source

    BAS006 - Larson Davis, Inc.

    The BAS006 is an innovative device used to create impulsive noise that includes low frequency energy and avoids problems like secondary bounce. These characteristics make it a great choice for quickly measuring reverberation time when the complexity and weight of a speaker and amplifier is not needed.

  • Industrial Sound Enclosures

    Eckel Noise Control Technologies

    The Convenient method for controlling noise and improving the work environment.

  • Omnidirectional Sound Source

    DS3 - NTi Audio AG

    The Dodecahedron Speaker Set offers a lightweight, yet powerful signal source for room & building acoustic measurements. The optimized frequency response ensures precise measurements in accordance with the ISO 16283 and the ISO 3382 standards. The set includes the robust omnidirectional DS3 odecahedron Speaker and the remote-controlled PA3 Power Amplifier. Equalized acoustic frequency spectrum from 100 Hz to 8 kHz.

  • Sound and Vibration Analyser

    SVAN 977 - Acu-Vib Electronics Acoustic & Vibration

    The SVAN 977 provides broadband results with all the standard weighting filters and also offers an incredible time history logging capability providing broadband results and spectra with adjustable double (long and short) logging steps. Audio recording can be performed simultaneously with time history logging as either a separate wave file or as audio events inside time history files. This solution enables noise source recognition and data post-processing. Manual and automatic triggering of audio recording is also available. Measurement results are recorded in three acoustic or vibration profiles enabling measurements to be performed with 3 different filters (e.g. A, C, Z) and 3 different detector time constants (e.g. Fast, Slow, Impulse).

  • Sound and Vibration Devices

    Data Translation, Inc.

    Directly measure IEPE-type accelerometers or voltage inputs with no added signal conditioning using USB and Ethernet data acquisition (DAQ) devices.