Showing results: 1336 - 1350 of 10562 items found.
-
RF096-18/30-155/307-HH Series -
RIFTEK LLC
The gauge is designed for non-contact scanning and measurement of the inner diameter (wear) of pipes. ID measurement range, mm / 18…30
-
mks Ophir
This sensor family provides cosine corrected irradiance measurement in W/cm² and dosage measurement in J/cm². The sensors are calibrated over their entire spectral range, and are thus ideal for irradiance and dosage measurement of UV, VIS and IR LED based light sources
-
NH Research, Inc.
Advanced control features beyond simple settings of voltage, current, & powerSimulation of real-world conditions (including transients and parameter adjustment)Built-in waveform digitizer & advanced measurement systemPrecision measurements with separate voltage/current rangesEliminates need for additional measurement devices
-
PCD 3100 -
Seibersdorf Labor GmbH
Site validation measurements according to prEN 50147-3 in fully anechoic rooms. Accurate RF radiation safety measurements (e.g. broadcast stations). All purposes of broadband precision field-strength measurements. Frequency range: 30 MHz - 1 GHz
-
VE series -
Ono Sokki
VE series are non-contact type of vibration/small displacement detector with high accuracy which can measure the distance between conductor such as metal and sensor’s surface in micron/submicron resolution. It demonstrates its best performance when used for the measurement and control of the axial and surface vibration of rotational shafts such as main shaft of turbines, electric motors, compressors, and of the thickness and width of moving objects. In addition to the measurement of the amount of displacement, a gap detector can also be used for a wide range of other measurement and control applications such as the measurement of the amount of slack or warping. The non-contact measurement process enables to apply no load to rotational or vibration body, and does not affect the material under measurement.
-
NRQ6 -
Rohde & Schwarz GmbH & Co. KG
The R&S®NRQ6 is based on receiver technology and can perform band-limited power measurements down to -130 dBm. The R&S®NRQ6 combines high-precision with high-speed measurements beyond the limits of currently available power meters. In addition to conventional continuous average measurements, the R&S®NRQ6 has a trace display function and also performs ACLR measurements.
-
MSR 500/1 CAR | VP 230035 -
Maschinenbau Haldenwang GmbH & Co. KG.
The MSR 500/1 single roller dynamometer is used in workshops for designers and tuners as well as in educational institutions. It is especially suitable for performance measurements, tuning and diagnostic work on particularly powerful vehicles. With test speeds of up to 300 km/h, it is used for dynamic and static power measurement. The MSR 500/1 CAR guarantees optimum measurement accuracy and reproducibility through the active measurement of the towing power.
-
AMETEK VTI Instruments
The RX product family includes 24-channel IEPE/voltage instruments (RX0424), 24-channel high performance bridge measurements (RX0124), 24-channel high performance charge vibration measurements (RX0224), and 32-channel thermocouple measurement systems (RX1032).VTI Instruments’s family of rugged instrumentation is designed and built to operate in some of the most extreme environmental conditions imaginable, without compromising measurement accuracy or performance.
-
MagCam NV
The fully digital and compact measurement system connects to a computer via a single USB cable, making the measurement data directly digitally available. The Magcam maps are analyzed in real time by the MagScope measurement & analysis software and its optional add-on software modules, which provide powerful measurement and analysis capabilities for a complete quality control and characterization of permanent magnets and magnet assemblies.
-
Atomtex
*Search and detection of gamma radiation sources with automatic identification of the radionuclide composition;*Measurement of the dose rate of gamma radiation;*Detection of neutron radiation and measurement of the neutron count rate (AT6102);*Measurement of the dose rate of neutron radiation (external detection unit BDKN-03);*Measurement of the flux density of alpha and beta particles from contaminated surfaces (external detection units BDPA-01 / BDPB-01)
-
Keysight Technologies
Keysight offers a wide range of benchtop LCR meters to meet your impedance measurement needs in the field of R&D, production, quality assurance, or incoming inspection. In addition to the high measurement performance and versatile functions of Keysight benchtop LCR meter, you will find the LCR accessories best suited for your measurement among a full lineup of Keysight impedance measurements.
-
RSR -
RARA Electronics Corporation
Power converters and current measurement instruments. Large current shunt resistor for ampere-meters, designed for standard current measurement of electric equipment. Easy current measurement is performed by attaching to current bus bar directly and connecting to ampere-meter through flexible wires.
-
Tokyo Seimitsu Co., Ltd.
Measurements of the length displacement or yawing and pitching, measurements of rotation angles, measurements of overshoots during vibrations or when stopped and of uneven speed, etc. can be handled. Length measuring instruments can be used for a variety of purposes, including precise inspection of heavy duty equipment.
-
BioSpec-nano -
Shimadzu Corp.
Capable of performing quantitation and purity checking of nucleic acids, quantitation of proteins, and photometric measurements (OD values displayed and printed for specified wavelengths, up to 8 wavelengths). Simply drop 1 to 2 μL of the sample onto the measurement window and press the instrument's Start button (or click the Start Measurement button in the software window), and all steps in the process, from setting the optical path length, measurement, up until the task of wiping off the sample from the measurement window, are all carried out automatically. Troublesome work of moving arm up and down and wiping the sample from the measurement window now unnecessary. Moreover, when using the specialized software, all it takes to perform a measurement, output a report, export data, or carry out other common tasks is to click buttons on the toolbar.
-
Arden Photonics LTD
*Improve measurement accuracy*Ensure stable launch conditions for multimode fiber measurements*Meet EF requirements of IEC 61280-4-1.