Filter Results By:

Products

Applications

Manufacturers

Showing results: 916 - 930 of 1119 items found.

  • Switch Mainframe

    SW1002 - HIOKI E.E. Corp

    Switch between voltmeter and battery tester while testing. 264 channels max. (2-wire) to 72 channels max. (4-terminal pair). Circuit design friendly for impedance measurements that minimize errors between channels (Effect: 0.01% f.s.*). For BT4560 100 mΩ range, R measurements, and a measurement frequency of 1 kHz. For OCV measurement, internal resistance measurement, and external potential measurement of battery cells. Measure battery modules up to 60 V DC.

  • Electroacoustic Analysis System

    CRY6125 - Hangzhou JiGao Electroacoustical Science and Technology Co.,Ltd

    CRY6125 series electro-acoustic device tester is a full-featured electro-acoustic device tester with anti-noise function. Measure the performance indicators of microphones, electret microphones (microphones), microphones, receivers, earphones, headset microphone assemblies, communication caps, speakers / speakers, buzzers and other electroacoustic devices. Such as: sensitivity (SPL), impedance, distortion (THD), resonance frequency F0, quality factor Q, equivalent volume, audio power amplifier, etc., the measurement frequency can reach 10Hz ~ 65kHz .

  • TIM Tester

    Analysis Tech Inc.

    The Analysis Tech TIM Tester 1300 is an automated test system for measurement of thermal impedance and conductivity on thin, thermally conductive materials of the type frequently used for electronic packaging, as well as a wide variety of flexible or rigid solids and semi-liquid or viscous materials. Generally, the TIM Tester 1300 can accommodate samples with high-to-medium thermal conductivity with contact pressures ranging from 10 to 550 psi (70-3800 kpa) and at sample temperature ranging from 15C to 70C.

  • 180V-260V AC Socket Tester (For UK)

    1941 - Peaceful Thriving Enterprise Co Ltd

    *With UKCA Approval.*LED indicators & Digital display.*Test for 180-260VAC circuit.I*t can perform self test after plug-in ( Voltage sould be above 180V ).*Detect faulty wiring status in 3 wire receptacle.*This socket tester will give LED indication as well if the main voltage is below 200V or above 260V.*Earth loop impedance test.*Power Plug type: UK 13A socket-outlet*Measurement Category: CAT II / 4W*Frequency: 50Hz

  • PCI-5105, 8‐Channel, 12-Bit, 60 MHz Bandwidth PCI Oscilloscope Device

    779686-03 - NI

    8‐Channel, 12-Bit, 60 MHz Bandwidth PCI Oscilloscope Device—The PCI‑5105 high-density oscilloscope device has eight simultaneously-sampled channels with flexible settings for coupling, impedance, voltage range, and filtering. Oscilloscope devices also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for applications with many channels that require up to 60 MS/s or 60 MHz of analog bandwidth.

  • PCI-5105, 8‐Channel, 12-Bit, 60 MHz Bandwidth PCI Oscilloscope Device

    779686-01 - NI

    8‐Channel, 12-Bit, 60 MHz Bandwidth PCI Oscilloscope Device—The PCI‑5105 high-density oscilloscope device has eight simultaneously-sampled channels with flexible settings for coupling, impedance, voltage range, and filtering. Oscilloscope devices also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for applications with many channels that require up to 60 MS/s or 60 MHz of analog bandwidth.

  • PCI-5105, 8‐Channel, 12-Bit, 60 MHz Bandwidth PCI Oscilloscope Device

    779686-02 - NI

    8‐Channel, 12-Bit, 60 MHz Bandwidth PCI Oscilloscope Device—The PCI‑5105 high-density oscilloscope device has eight simultaneously-sampled channels with flexible settings for coupling, impedance, voltage range, and filtering. Oscilloscope devices also feature a number of triggering modes, deep onboard memory, and an instrument driver that includes data streaming and analysis functions. This device is ideal for applications with many channels that require up to 60 MS/s or 60 MHz of analog bandwidth.

  • Dual Channel Clock Driver Card

    PI-41400 - Pulse Instruments

    The PI-41400 is a dual channel Clock Driver card capable of operating up to 190 MHz into a 50-ohm load and up to 80 MHz at an amplitude of 8 volts into a 1-megohm load. Into a high impedance load the output voltage range is from a –3 volts to 8 volts with the output pulse amplitude ranging from 0.5 V to 9 V. When driving a 50 load the voltage range is –1.5 volts to 4.5 volts with the output pulse amplitude ranging from 0.25 V to 4.5 V. The rise and fall times of the output pulse are variable from 1.2 ns to 9 ns into a 50-ohm load and <5 ns to 9 ns into a HiZ load. The output pulse amplitude and the load being driven determine the range of variability. The driver output can be set for tri-state operation and the output polarity can be set for ‘Normal’ or ‘Inverted’ operation through software.

  • 75 Ohm 1.6/5.6 Connectors

    Pasternack Enterprises, Inc.

    Pasternack 75 Ohm 1.6/5.6 connector category includes many part numbers, the majority are RoHS and REACH compliant. 75 Ohm 1.6/5.6 connector series in this category will terminate to coax or PCB (printed circuit board). Our 75 Ohm 1.6-5.6 connectors are built to precise industry specifications. 75 Ohm 1.6-5.6 connectors are constructed in jack or plug gender with 75 Ohm impedance. 75 Ohm 1.6/5.6 connectors are available in straight or right angle versions, as well as, bulkhead or mountless options. These 75 Ohm 1.6-5.6 connector designs include clamp/solder, crimp/solder or solder attachment methods. Like the other over 40,000 RF, microwave and millimeter wave Pasternack products, this 75 Ohm 1.6/5.6 connector series is in-stock. Not only are these 1.6 / 5.6 connectors in stock, but they also will ship the same day as they are purchased.

  • CAN/FlexRay/Differential Bus PXI Fault Insertion Switch - 4 Channel

    40-200-004 - Pickering Interfaces Ltd.

    Each channel can support up to 0.3A and is rated to handle up to 100V between the wire pairs. The wire pairs have controlled transmission line impedance suited to most differential pair signaling systems, including fast CAN Bus interfaces and RS232. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.

  • Cable & Antenna Analyzer

    Shanghai Tarluz Telecom Tech Co., LTD

    Adopting new techniques like advanced radio frequency and digital hybrid integration design, broadband and fundamental wave mixing, digital IF processing and intelligent power management, etc., The Cable and Antenna Analyzer has advantages of fast measuring speed, high measurement accuracy, small size, light weight, battery power, touch screen operation and adjustable backlighting. It can measure return loss, standing wave ratio (SWR), impedance, phase, DTF (discontinuity point fixing), etc.

  • Dual Channel 14-bit 3.0 GSPS Analog to Digital Converter

    ADC32RF45 - Texas Instruments

    The ADC32RF45 is a 14-bit, 3.0-GSPS, dual-channel, analog-to-digital converter (ADC) that supports RF sampling with input frequencies up to 4 GHz and beyond. Designed for high signal-to-noise ratio (SNR), the ADC32RF45 delivers a noise spectral density of –155 dBFS/Hz as well as excellent dynamic range and channel isolation over a large input frequency range. The buffered analog input with on-chip termination provides uniform input impedance across a wide frequency range and minimizes sample-and-hold glitch energy.

  • 16 Channel Multievent QDC

    V792N - CAEN S.p.A.

    The Model V792N is a 1-unit wide VME 6U module housing 16 Charge-to-Digital Conversion channels with current integrating negative inputs (50 Ohm impedance). For each channel, the input charge is converted to a voltage level by a QAC (Charge to Amplitude Conversion) section. Input range is 0 ÷ 400 pC. The Model V792N features LEMO 00 connectors for both input and control signals. The outputs of the QAC sections are multiplexed and subsequently converted by two fast 12-bit ADCs.

  • Burn Down Transformer

    ATG 2 - BAUR Prüf- und Messtechnik GmbH

    Cable fault location with the BAUR ATG 2. The ATG 2 burn down transformer is used for impedance reduction of cable faults in low- and medium-voltage networks. The short-circuit proof 2300 VA stray field transformer delivers a maximum voltage of 10 kV and is housed in a fully enclosed 19" housing.* Portable device for changing the fault resistance* Useful for cables that are difficult to access* Proven methods for complicated faults* Independent current and voltage control on each burning level

  • Audio Frequency System

    Locator Set / UL 30 - BAUR Prüf- und Messtechnik GmbH

    Cable fault location with the BAUR Locator Set / UL 30. The audio frequency system Locator Set is used to exactly determine the alignment of cables and metal gas or water pipes. With various accessories, this system becomes a universal, indispensable device for power companies, industries, installation companies and water suppliers.* Output energy up to 50 VA* Automatic or manual impedance adjustment* Charging unit and rechargeable battery integrated; battery or mains operation* Continuous or cyclical output

Get Help