Filter Results By:

Products

Applications

Manufacturers

Showing results: 781 - 795 of 1119 items found.

  • PXI/PXIe Microwave Transfer Switch, Dual, 50 GHz, 50 Ω, SMA-2.4, Failsafe, Remote Mount

    42-782B-552-E - Pickering Interfaces Ltd.

    The 40-782B-552-E (PXI) and 42-782B-552-E (PXIe) dual failsafe transfer switches with remotely mounted relays are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 50 GHz. Connections are made via front panel mounted high quality SMA-2.4 coaxial connectors.

  • PXI/PXIe Microwave Transfer Switch, Dual, 50 GHz, 50 Ω, SMA-2.4, Failsafe, Remote Mount

    40-782B-552-E - Pickering Interfaces Ltd.

    The 40-782B-552-E (PXI) and 42-782B-552-E (PXIe) dual failsafe transfer switches with remotely mounted relays are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50 Ω and a maximum operating frequency of 50 GHz. Connections are made via front panel mounted high quality SMA-2.4 coaxial connectors.

  • HIGH FREQUENCY DC BIAS

    6565 SERIES - Wayne Kerr Electronics, Ltd.

    The 6565 HF DC Bias Unit is intended to be used with a Wayne Kerr 6500 analyzer, either the 6500B Precision Impedance Analyzer or the 6500P HF LCR Meter. Its function is to provide a source of DC bias current through the Device Under Test (DUT) while the analyzer is making AC measurements. Each 6565 unit can provide up to 10 A of DC current, and up to six 6565 units can be connected in parallel to supply a maximum 60 A. A digital ammeter on the front panel allows the user to see the dc bias current value and an indicator LED shows when the bias current is enabled.

  • VXS 21 Slot

    Comtel Electronics

    The Comtel VXS Backplane 21 slots match performance and cost-effectiveness by realising a fully optimised signal and power distribution environment. Design techniques ensure uniform impedance controlled signaling environment and ground guarding minimises line-to-line crosstalkThe VXS provides the high-speed switched serial performance of VITA 41, hybrid design includes VXS payload slots, VXS switch slots and conventional VME64x slots, The 21 slot VXS backplanes supports data rates well beyond 3.125Gb/s per link. As a dual-star design, it can be operated with two switch boards, allowing addressing of both link ports on payload cards.

  • Fault Locating

    Schweitzer Engineering Laboratories, Inc.

    The built-in fault-locating methods in SEL devices allow you to quickly identify faults, dispatch crews for repairs, and restore service faster. Traveling-wave fault-locating technology calculates the locations of temporary and permanent faults by measuring the arrival times of the naturally occurring traveling waves caused by a transmission line fault. Accurately detecting these waves requires ultra-high-resolution monitoring, and locating is accurate to within one tower span (±300 m). Impedance-based fault-locating technology calculates fault locations by detecting changes in line impedance as a result of a fault. Impedance-based locating is reliable and accurate to about 2 percent of a line’s total length.

  • Bulk Current Monitoring Probe

    MP-50 - FRANKONIA GmbH

    The Current Monitoring probes may be used whenever RF current measurements are required. Current measurements are made by placing a current carrying conductor within the “sensing” window of the probe and measuring the probe’s output voltage with an RF detector. Calibration of the probe permits the conversion of the voltages measured to current. Current measurements can be made over the frequency range shown in the transfer impedance curve furnished with each probe. There is virtually no loading of the circuit and the technique permits normal operation of the device under test during measurements. The MP-50 can be used for the procedure for clamp injection when the common- mode impedance requirements cannot be met given in chapter 7.4 of IEC/EN 61000-4-6 „Immunity to conducted disturbances, induced by radio frequency fields”. The MP-50 can also be used as current monitor for BCI testing as per ISO11452-4, RTCA/DO-160 section 20, MIL-STD-461 and various automotive standards.

  • Electric Fence Chargers

    Mark 8 - Parker McCrory Manufacturing Co.

    The all new Mark 8, low impedance fencer gives you the stock holding power that you have always wanted. Shocks right through wet weeds or brush and over extremely dry ground. Features Parmak`s exclusive built-in DIGITAL performance meter that tells you the exact condition of the fence. Takes the guesswork out of electric fencing. 100% solid state, with all new low impedance, uni-junction circuitry. No moving parts. Ideal for use with high tensile single or multi-wire fences. New color coded fence and ground terminals. Red to the fence and Black to ground. The Mark 8 operates for less than 7 cents a month at 7 cents per kwh. Fuse protection, with new built-in lightning arresters. Full 3 year warranty covers damage caused by lightning.

  • Protection Testing Software

    F6TesT Software - Doble Engineering

    Doble's F6TesT software is a visually-robust software for simple, fast, and automated protective relay testing, including the testing of complete protection schemes.F6TesT has an intuitive user interface and features graphical protection-test modules. These modules simplify testing impedance, differential, current, voltage, directional, frequency, volts-per-hertz, rate-of-change of frequency, sync-check, reclosing and all other functions.

  • Transient Limiters

    Com-Power Corporation

    Transient limiter LIT-153A and LIT-930A protects a spectrum analyzer input from high-level transients from the line impedance stabilization networks during EMC conducted emissions testing. It has a combined frequency range of 9 kHz to 30 MHz. The built in high pass filter helps reduce 50/60 Hz line feed through. (see application notes)

  • PXI Dual SP6T Multiplexer 6GHz 50 SMA

    40-784A-002 - Pickering Interfaces Ltd.

    Pickering Interfaces' range of 40-784A PXI Microwave Multiplexer Modules have a characteristic impedance of 50 and are capable of switching signalsup to 40GHz. Available in single, dual or triple, SP6T or SP4T formats, they are suitable for constructing complex microwaveswitching networks and provide a range of switching configurations to suit most applications. Connection is by high performancefront panel mounted SMA or SMA-2.9 connectors

  • AC/ DC mA Current Clamp-on Transducer

    CA-60 - Tecpel Co., Ltd.

    This miniature clamp meter features two Hall effect sensors. For use with any multimeter with 200mV or/and 2V ranges for direct readout input impedance of least 1M ohm. High conversion factor for low DC and AC mA measurement. With the small jaw size it can fit into tight space in circuit panel or wire bundle to take the reading.

  • LXI Single 24x8 50 Ohm HF Matrix BNC

    60-760-005 - Pickering Interfaces Ltd.

    The 60-760-005 is a single 24x8 High Frequency Matrix Module suitable for switching frequencies up to 50MHz. It has an impedance of 50Ω and uses BNC signal connectors. It is also available in a smaller enclosure with SMB Connectors. It is designed to provide simple and scalable switching for radio frequencies and is intended for the easy construction of high performance bidirectional matrix switching systems.

  • Fault Diagnostics in Power-Off State

    QT55 - Qmax Test Technologies Pvt. Ltd.

    Signature Method of Testing is also known as VI Trace Characteristics, is a proven fault diagnostics technique in Power-Off state while testing a board. By applying known wave from signal with desired Voltage, Source impedance and Frequency of the stimulus signals, depending upon the test node and its characteristics, a Voltage (V) vs Current (I) graph is plotted and studied.

  • Clamping Voltage Tester

    MIG0603CLV2 - EMC Partner AG

    The MIG0603CLV2 is a generator for clamping voltage testing of varistors. It has circuits with four different source impedances and up to 15 different measurement ranges. The instrument is used to perform varistor clamping voltage tests on up to 1000 V varistor types. The test impulse is a 8/20µs current waveform up to 500A which is maintained over the entire load range.

  • True Dual-Channel Analysis on iOS

    IOScope - Faber Acoustical, LLC

    With IOScope, measure loudspeaker impedance, frequency response, and sensitivity. Measure a room impulse response. Tune a large sound reinforcement system, time-align a set of surround sound speakers, or optimize your home stereo. Determine the actual cutoff frequencies of your latest speaker crossover circuit, or teach your students the fundamentals of Fourier analysis of dynamic systems.

Get Help