product
1203c Broadband RF Distribution
Precise Time and Frequency, Inc.
The ptf 1203C Broadband RF Distribution amplifier provides high performance frequency references for laboratory or system use.The ptf 1203C uses two stages of input signal buffering to distribute the input signal to 12 separate outputs, and insure maximum isolation between individual output signals.
-
product
Amplitude Detectors with Isolators
Full band waveguide detectors are GaAs beam lead Schottky diode-based detectors that are specially designed for millimeterwave network analyzer applications. With a proprietary circuitry design and careful diode selection, these zero-biased detectors exhibit high sensitivity and extremely flat output characteristics. The below standard offering covers the frequency range of 18 to 170 GHz and offers a 1 MHz video bandwidth and 1 MΩ video output impedance. The standard models also have the capacit...show more -
product
Artificial Power Supply Network
KH3762
Beijing KeHuan Century EMC Technology Co,.LTD
The artificial power supply network (also called the power supply impedance stabilization network) should be able to provide a stable impedance to the device under test in the radio frequency range, isolate the device under test from high-frequency interference on the power grid, and then couple the interference voltage to the receiver.
-
product
Standard 1.90 (53.90) - 8.00 (226.80) High Frequency Probe
CSP-40B-012
Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Full Travel Remark: Shield: 275 (6.99) including travel of probesRecommended Travel (mil): 133Recommended Travel (mm): 3.38Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,151Overall Length (mm): 29.24
-
product
Standard 4.47 (127.00) - 12.00 (340.00) High Frequency Probe
K-50B-S
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 4.00Return Loss @ -20dB (GHz): 2.50Nominal Impedance (Ohms): 50Test Center (mil): 600Test Center (mm): 15.24Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 90Recommended Travel (mm): 2.29Overall Length (mil): 1,205Overall Length (mm): 30.61
-
product
Hydrophone
TC4047
The TC4047 miniature hydrophone offers a useable frequency range from 1kHz to 170kHz. The hydrophone incorporates a high quality 20dB low-noise pre-amplifi er which provides optimal conditions for signal transmission. The high sensitivity provides excellent signal to noise ratio and immunity against induced cable noise. The hydrophone is omnidirectional up-to 100kHz and has uniform receiving characteristic from 1kHz to 100kHz. An insert calibration circuit enables remote testing of the hydrophon...show more -
product
Multi SDI Monitors
LV 5333
LV 5333 Waveform Monitor is a powerful, versatile video production tool that is compact and portable. LV 5333 has a high quality TFT LCD screen which produces high quality picture images. Waveform, Vector, Audio, Status and 5 Bar gamut displays are all included in this precision instrument. These can be displayed full screen or in various multi-display combinations. LV 5333 can also display the levels of an embedded audio signal. Plus, Cable Length, External Phase Difference, and Field Frequency Deviation measurements are standard along with CINELITE® II. Now with HD HDR monitoring as an option, the LV 5333 can be carried as a portable unit or rackmounted for studio or flypack use.
-
product
Bench Power Supplies
Series ABC
Kepco¹s ABC bench power supply embodies the latest features: keyboard data entry, interactive digital display, integral GPIB support, software calibration, high frequency switch mode conversion, wide range input (85-264V a-c) and power factor correction. It meets the EN 61000-3-2 harmonic limits. A built-in EN 55022 Class B input EMI filter is provided. Integral External Trigger and RS 232 ports are now standard features.
-
product
Jumbo LCD Autoranging Digital Multimeter w/Bargraph
HH2210
Auto Ranging High Voltage test up to 1000V DC and 750V AC. Higher Current test up to 20A AC/DC. Diode test and Transistor test. Continuity check with buzzer sound. Measure Resistance up to 30MΩWide. Frequency test range up to 300kHz
-
product
Sub-mm Sources From 179 To 1250 GHz Based On BWO
Insight Product Company offers BWO based sub-mm wave sources of radiation in frequencies from 179 GHz to 1250 GHz. Each source includes a sub-mm wave BWO tube and a specially designed permanent magnet. BWO tube is installed inside the permanent magnet and does not require any adjustments by the customer. Offered sources are the most wide banded, they are very reliable, small sized, powerful and easy to operate. They allow users to control frequency in very wide band and with extremely high speed.
-
product
PXI/PXIe Microwave Transfer Switch, Dual, 18GHz, 50Ω, SMA
40-782B-522
The 40-782B-522 (PXI) and 42-782B-522 (PXIe) dual transfer switches are part of our range of PXI microwave switching modules. They have a characteristic impedance of 50Ω and a maximum operating frequency of 18GHz. Connections are made via front panel mounted high quality SMA coaxial connectors.
-
product
Low CxR
Is a low output capacitance solid state relay containing a GaAs LED on the light emitting side (input side) and MOS FETs on the output side. A small flat-lead package has been provided which realizes a reduction in mounting area of about 50% compared withthe PS78xx series. It is suitable for high-frequency signal control, due to its low C × R, low output capacitance, and low off-state leakage current.
-
product
Reference Frequency Generator
MFCh
*Frequency reproduction accuracy ± 2 x 10 -9 *Output frequency 1 Hz - 10 MHz *Output pulse signal 1 kHz The MFC is designed to generate high-frequency pulse signals with a frequency of 1 kHz and a frequency in the range from 1 Hz to 10 MHz along two output lines. The MFC is designed to operate in measuring systems based on the VXIbus trunk. In the MFC, a rubidium frequency standard is used as a reference frequency source. Time to reach the mode when the power source of the rubidium standard is turned on, no more than 10 min
-
product
Impedance Analyzer
MFIA
The Zurich Instruments MFIA is a digital impedance analyzer and precision LCR meter that sets the new standard for impedance measurements in the frequency range from DC to 5 MHz. The MFIA provides 0.05% basic accuracy and a measurement range spanning from 1 m to 10 G. The instrument has a high measurement repeatability and a small temperature drift. With the LabOne user interface the MFIA offers a number of long-awaited innovations for the impedance and LCR measurement available without the need of any software installation.
-
product
DC Blocking Power Splitter Combiner
PD5012
INSTOCK Wireless Components, Inc
Wideband Frequency (698 - 2700 MHz)Low Insertion Loss (0.6 dB avg)High Port to Port Isolation (30 dB avg)Excellent VSWR (1.15 : 1 avg)50 VDC maximum on DC block portsTri Alloy Type N Female (Jack) Low PIM
-
product
Electronic Ballast High Frequency Parameters Tester
UI2002A
• Measure Vrms, Irms, W, PF/Hz • Voltage range: 10~600V, Current range: 10~2000mA, Frequency range: 20~70kHz • Accuracy: Class 2
-
product
Active Voltage Probes
Engineers must commonly probe high-frequency signals with high signal fidelity. Typical passive probes with high input R and C provide good response at lower frequencies, but inappropriately load the circuit, and distort signals, at higher frequencies. Active voltage probes feature both high input R and low input C to reduce circuit loading across the entire probe/oscilloscope bandwidth. With low circuit loading, and a form factor that allows probing in confined areas, the active voltage probe becomes the everyday probe for all different types of signals and connection points.
-
product
High Frequency Transformers
Osborne High Frequency Transformers are isolation transformers and auto-transformers that operate at frequencies higher than 50/60 Hertz. Osborne recommends high frequency operation for certain applications that demand a significant reduction of the physical size of electromagnetic components. Osborne helps our clients take advantage of higher frequency designs by identifying and accommodating (or preventing) high frequency loss characteristics, such as skin-effect losses, proximity effect losses and stray losses.
-
product
Process Calibrator
MC-1000
The MC-1000 Process Calibrator provides high accuracy calibration, common DMM functions including read and source thermocouples, RTDs, Ohms, current, pressure, frequency and test continuity. This single calibration instrument will calibrate virtually any process device including: read and source thermocouples, RTDs, Ohms, Voltage, Current, Frequency, Pressure, and test continuity.
-
product
Handyscope TP450-50XM-W5
TP450-50XM-W5
The Handyscope TP450 is a power quality analyzer, connected via USB to the computer. The advanced measurement software delivered by default contains Quick Setups that allow to start mains power logging measurements without specialized instrument knowledge. With the 450 V input range, the Handyscope TP450 can be plugged directly in a (110 - 230 V) wall socket to measure the mains voltage. No additional attenuator is required. Logging mains voltage can be done at a high rate of 250 thousand measur...show more -
product
Standard 0.80 (22.00) - 4.00 (114.00) High Frequency Probe
CSP-03B-006
Current Rating (Amps): 6Bandwidth @ -1dB (GHz): 3.70Return Loss @ -20dB (GHz): 1.80Dielectric VTE Rating (k VAC): 1Nominal Impedance (Ohms): 50Test Center (mil): 300Test Center (mm): 7.62Full Travel (mil): 250Full Travel (mm): 6.35Recommended Travel (mil): 167Recommended Travel (mm): 4.24Overall Length (mil): 1,090Overall Length (mm): 27.76
-
product
Metallic Corrosion Detector
Xiamen IDEA Electronic Technology Co., Ltd.
Portable Metal Corrosion Detectors , is used for testing the steel pipe corrosion, stainless-steel tube corrosion and sheet materials corrosion, which can tell the high rate color LCD, can adjust phase, gain and testing frequency ,can used for testing the different metallic corrosion , such as corrosion pit, fluid dust scouring thickness reduction,crack, oxygen corrosion and hydrogen corrosion. has English and chinese operating interface, simple and visual operation.
-
product
High AC Current Capacitor
LC1/LC2/LC3-BN
Induction Heating Processing Equipment, Electric Current Welding, Resonant Circuits, Motor Controls; Oscillating, Bypass, Coupling circuits, High AC Current applications, High-Frequency AC Filter and Medium Frequency Power applications.
-
product
Low Phase Noise Amplifiers
Pasternack's low phase noise amplifiers cover select frequency bands ranging from 1.5 to 18 GHz with residual phase noise levels as low as -180 dBc/Hz @ 10 KHz offset. Additional performance specs include small signal gain ranging from 9 to 14 dB, with typical noise figure of 5.5 dB. Psat levels for these amplifiers range from +16 to +25 dBm with Output IP3 levels as high as +34 dBm. All models feature single DC voltage supplies and input/output RF ports are internally matched for 50 ohms with...show more -
product
RSE Wireless EMC Spurious Emission
TS8996
The R&S®TS8996 RSE test system is designed for EMI and radiated spurious emission testing on wireless devices in semi-anechoic or fully anechoic chambers. The modular design makes it easy to extend the system to include new communications technologies. Typical devices under test include mobile phones or radio sets along with radiated measurements of other short-range devices. Standards require a wide range of test setups and a wide and high frequency range (up to 40 GHz). ESW or FSW frequency ranges are extended up to 325 GHz with option B21 using receive units TC-RSE for 5G FR2. Dedicated RSE test routines are also covered for this frequency range.
-
product
Hydrophone
RESON TC 4040
The TC4040 is an ideal standard reference hydrophone for calibration of transducers, hydrophones and underwater acoustic measurement systems.The TC4040 offers flat frequency receiving response over a wide frequency range and the relatively high transmitting sensitivity makes it very useful within many areas of underwater acoustic research, tests and measurements.
-
product
1202a High Frequency Distribution
Precise Time and Frequency, Inc.
The ptf 1202A High Frequency Distribution amplifier provides high performance frequency references for laboratory or system use requiring distribution at frequencies of 30MHz and above.The ptf 1202A is especially designed to distribute the high frequency input signal to 12 separate outputs, with minimum signal distortion and maximum isolation between individual output signals.
-
product
High Frequency Insulation Tester
HFIT 8.0
The MEDTEQ HFIT 8.0 is intended for high frequency insulation testing against IEC 60601-2-2. This version includes in-built metering and automatic functions to make testing easy not only for design and laboratory testing, but also suitable for regular production testing.
-
product
Double DDS Core
AllWin Instrument Science and Technology Co., Ltd.
1. Double DDS core,high accuracy and high stability2. Store more than 20 kinds of waveforms3. Frequency range: 1 Hz~120 MHz
-
product
High Frequency Connectors
C.C.P. Contact Probes Co., LTD.
CCP is an expert in the design of high frequency connectors. We offer 5G ready connectors and USB 3.2 connectors.