Filter Results By:

Products

Applications

Manufacturers

Flux

the rate of flow.


Showing results: 106 - 120 of 162 items found.

  • ESD Safe Fume Absorber

    O.C. White Company

    ESD safe, carbon-activated fume absorber. Flux creates "pine resin", which creates noxious fumes. These fumes cause headaches and nausea. This unit quickly removes these fumes from the work area and filters them safely. Only this newly developed unit, mounted on its versatile 37" arms, allows easy movement to effectively remove these irritating fumes fast.

  • Photometric Probes for Illuminance

    LPPHOT03… Series - Delta OHM S.r.L.

    The probe LPPHOT03 measures illuminance (lux), defined as the ratio between the luminous flux (lumen) passing through a surface and the surface area (m²). The spectral response curve of a photometric probe is similar to the human eye curve, known as standard photopic curve V(λ). The difference in spectral response between LPPHOT03 and the standard photopic curve V(λ) is calculated by means of the error f’1.

  • Spectroradiometer

    Lisun Electronics Inc.

    Spectroradiometer is usually used with a integrating sphere to measure the photometric and colorimetric parameters of all kinds of lamps. Relative spectral power distribution P(λ), chromaticity coordinate (x,y), (u,v), correlated color temperature Tc, color rendering index Ra, dominant wavelength, peak wavelength, spectral bandwidth, color purity, color ratio, SDCM, luminous flux, etc.

  • Standard Light Source

    SLS-50W - Lisun Electronics Inc.

    OSRAM Standard Lamp to calibrate the spectrum and luminous flux with Lisun Lab certification. The data can be traced NIM. The Standard Lamp Source is used to calibrate the integrating sphere system. The different size of Integrating Sphere should choose the right power of standard lamp source.

  • LED Fast-Scan Micro-Spectrophoto Colori meter

    8000 - Shenzhen Chuangxin Instruments Co., Ltd.

    The system can determine spectral power distribution, chromaticity coordinates, correlated color temperature, color rending index (Ra), color difference, peak wavelength, spectral half width, dominant wavelength, color purity, luminous flux, test for photometry colorimetry electricity of LED characteristics.

  • Scanning XPS/HAXPES Microprobe

    PHI Quantes - Physical Electronics

    The PHI Quantes is the only commercially available automated, high-throughput lab-based HAXPES spectrometer. It is a unique scanning X-ray photoelectron microprobe that combines a high energy (HAXPES) monochromatic X-ray source (Chromium Kα) with a conventional monochromatic soft X-ray source (Aluminum Kα). Both sources are high flux focused X-ray beams that can be scanned across the sample surface and can be used to define analysis points, areas, lines, and maps with 100% confidence.

  • L.V.D.T Products

    Columbia Research Laboratories

    Columbia's L.V.D.T.'s are designed for the most demanding high temperature military and industrial applications where maximum life under adverse conditions is required. The corrosion resistant stainless steel housing provides effective shielding to contain the magnetic flux within the transformer, as well as providing protection against external magnetic fields. Conservative design permits the use of these transducers well beyond their specific linear range with minimum loss of accuracy.

  • Magnetic Material Test Fixture

    16454A - Keysight Technologies

    The 16454A is designed for accurate permeability measurements of toroidal-shaped magnetic materials. Since the construction of this fixture creates one turn around the toroid (with no magnetic flux leakage), the need of winding a wire around the toroid is unnecessary. Complex permeability is calculated from the inductance with and without the toroid. When the E4991A/4291B with option 002 is used as the measurement instrument, direct readouts of complex permeability are possible. In addition, it is furnished with a small and a large fixture to adapt to a wide range of sizes.

  • Integrating Spheres

    Instrument Systems Optische Messtechnik GmbH

    Determination of radiant power or luminous flux from light sources with the aid of integrating spheres is one of the most important procedures in photometry. Designed as a hollow sphere whose inner surface is coated with a diffusely reflecting material, the integrating sphere ensures complete integration and mixing of light radiation. This is then output on a detector port for measurement.

  • Motor/Gasoline Engine RPM Detector

    OM-1500/1200 - Ono Sokki

    The OM-1500/1200 motor/gasoline engine RPM detector is designed for rotation measurement of a gasoline engine and an EV/HEV motor. It detects magnetic flux leakage from the motor itself or the engine’s ignition coil.This easy to use and durable detector can measure engine rotation by attaching in parallel with the ignition coil. When the EV/HEV motor rotation is measured, attach the OM-1500/1200 perpendicular to the motor rotating shaft.It is used with the engine tachometer by Ono Sokki (GE-2500, AR-7240B, CT-6520B, HT-6200, SE-1620, FT-2500, FT-7200).

  • Refractometers

    Bestone Industrial Ltd.

    The series is developed for working with sugar related liquids (fruit juices, soft drinks、 wine), help monitor and control sugar concentrations in foods and beverages. Whether users are checking the "ripeness" of fruit in the field, verifying product quality after harvesting, or controlling concentrations during processing and packaging, refractometers provide critical information to ensure product quality. But,it is also commonly used for controlling the concentration of various industrial fluids cutting lubricants and flux rinsing compounds). Full ranges of measurement is available.

  • Digital Teslameters/Gaussmeters

    Group3 Technology

    S Digital Teslameters offer accurate, high resolution measurement of magnetic flux densities, withdirect digital readout in tesla or gauss, and serialcommunications by fiber optics or RS-232C for system applications.The instruments are light and compact, and the probes are easy to use. The DTM-151 has been engineered to withstandthe severe electrical interference produced by high voltage discharge.

  • Custom Magnetic Recording Heads

    International Electro-Magnetics, Inc.

    We have manufactured over 5,000 different head designs. If we don't have one to suit your requirements, we will design and build to your specification. Our toolroom is well equipped to produce precision parts, and our design projects have included flux sensing systems, magnetic disk encoding, and electronic test equipment.

  • Open Loop Current Sensor

    C03 30A - Luksens Technology GmbH

    The C03 offers efficient and precise sensor solutions for direct, alternating and pulsed currents in industrial, commercial and communication systems. It consists of three main components: an accurate, linear Hall sensor with low temperature drift, a flux collector and a transformer. It is characterized by a very low resistance and thus lowers power loss and temperature drift - for optimal performance.

  • Cold Atomic Beam System

    AOSense

    Detailed description of item: Complete cold atomic beam sources for alkaline-earth precision experiments and atomic devices. Small chambers with patented permanent-magnet Zeeman slowers and in-vacuum 2D MOT optics allow high flux with low outgassing and no thermal beam flux at the cold atom port, which provides a CF-133 connection to customer vacuum chamber. Advanced thermal design of the effusion oven allows long-lifetime operation at minimal heating power, with no water cooling. An integrated low-outgassing hot window is provided for coupling of on-axis Zeeman cooling light. Ion and getter pumps integrated into the chamber manage outgassing from the oven at temperatures up to 520 °C. Operating baseline pressures below 1×10-11 mbar can be attained in the customer’s downstream cold atom (typically 3D MOT) science chamber, with suitable pumping speed provided at the differentially-pumped cold beam output port.

Get Help