Flux

the rate of flow.


Showing results: 121 - 135 of 162 items found.

  • Open Loop Current Sensor

    C03 50A - Luksens Technology GmbH

    The C03 offers efficient and precise sensor solutions for direct, alternating and pulsed currents in systems for industry and commerce as well as in communication systems. It consists of three main components: an accurate, linear Hall sensor with low temperature drift, a flux collector and a transformer. It is characterized by a very low resistance and thus lowers power loss and temperature drift - for optimal performance.

  • Differential Scanning Calorimeter

    DSC-L600 - Thermtest Instruments

    The Differential Scanning Calorimeter (DSC-L600) is a powerful thermal analysis instrument that measures the heat flow of a sample as a function of time or temperature. The DSC-L600 has been designed to be a cost-effective instrument that is well suited for research or QC applications. The instrument communicates with the PC via a RS232/USB connection. The specially designed heat flux plate has demonstrated more than twice the sensitivity than other heat flow type DSC’s on the market. The reproducibility is excellent, and the noise level is virtually unnoticeable due to a precision high gain, low noise differential amplifier

  • Advanced Tachometer

    FT-2500 - Ono Sokki

    FT-2500 advanced tachometer measures the rotational speed by using the signal of change in sound, vibration or magnetic flux from rotating machines such as motor or the like.The use of FFT technology enables the FT-2500 to calculate and display the rotational speed of any complex waveform signals from microphone, sound level meter or vibration sensor by extracting the frequency component which is equivalent to the rotational speed.

  • LED Lighting Test Instrument Integrating Sphere

    CX-I.5S - Shenzhen Chuangxin Instruments Co., Ltd.

    Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.

  • LED Tester0.3m-2m Integrating Sphere

    CX-8000 - Shenzhen Chuangxin Instruments Co., Ltd.

    Measure Luminous Flux, Luminous efficacy, radiant power, Spectral Power Distribution, Chromaticity Coordinate, Correlated Color Temperature, Peak Wavelength, Dominant Wavelength, Spectral Half Width, Color Rendering Index, Colorimetric Purity, red ratio, Standard deviation of color matching(SDCM), voltage, current, power, power factor, harmonics, and etc. It meets the requirements of CIE standards.

  • OTDR Launch Boxes

    Arden Photonics LTD

    Arden’s MPX Modal Explorer makes measurement of Encircled Flux easy, and accurate, and it complies with international standards. But if you are measuring laser-based transmission light sources for multimode systems you may need to use a test jumper assembly and fiber shaker in order to avoid “speckle”. Industry standards (for example IEEE 802.3aq and FOTP– 203) call for the use of a mechanical fiber shaker.

  • Spectrometers

    Atomtex

    *Search and detection of gamma radiation sources with automatic identification of the radionuclide composition;*Measurement of the dose rate of gamma radiation;*Detection of neutron radiation and measurement of the neutron count rate (AT6102);*Measurement of the dose rate of neutron radiation (external detection unit BDKN-03);*Measurement of the flux density of alpha and beta particles from contaminated surfaces (external detection units BDPA-01 / BDPB-01)

  • Fiber Shaker

    MPX-SR3 - Arden Photonics LTD

    Arden’s MPX Modal Explorer makes measurement of Encircled Flux easy, and accurate, and it complies with international standards. But if you are measuring laser-based transmission light sources for multimode systems you may need to use a test jumper assembly and fiber shaker in order to avoid “speckle”. Industry standards (for example IEEE 802.3aq and FOTP– 203) call for the use of a mechanical fiber shaker.

  • Instrument Systems Goniophotometers

    Konica Minolta Sensing Americas, Inc

    If you need assistance measuring angle dependent spectral measurements, Instrument Systems has developed a comprehensive line of goniophotometers to meet your needs. Instrument Systems Goniophotometers are used to analyze angle dependent spatial radiation properties of SSL lamps and LED modules. Instrument Systems has two varieties of goniophotometers, one used for Large SSL lamps and LED modules as well as one designed for use in small to medium SSL Luminaries and LED modules. These instruments are capable of exporting data in an easily readable EULUMDAT format and provide exceptionally accurate measurement of luminous intensity distribution and luminous flux. The LGS 1000 model has an optional addition of a luminous flux integrator. Instrument Systems also offers a Type C Design for that particular goniophotometer model which is designed with a horizontal optical axis. This makes setting up a measuring path much simpler and allows measurements for specimens up to 1900mm in diameter.

  • Photometers & Colorimeters

    Instrument Systems Optische Messtechnik GmbH

    A photometer is used to measure the photometric quantities of illuminance (lx), luminous intensity (cd), luminous flux (lm), and luminance (cd/m²). The integral method and the fast response time of silicon photodiodes means that photometers can achieve an outstanding measuring speed. They are therefore ideal for performing fast goniophotometric measurements. We take great care in the development and production of photometer heads and use innovative amplifier technologies.

  • Lamp-Based Calibration Light Sources

    Gamma Scientific Inc.

    Lamp-based calibration light sources from Gamma Scientific are used for optical calibration of light measurement instruments including spectroradiometers, photometers and radiometers. All of our calibration light sources meet rigid quality standards for use in the most challenging testing environments. A wide range of light sources is available to serve as precision standards of radiant flux and white-light standards of spectral irradiance or luminance.

  • Goniophotometer

    PIMACS CO., LTD.

    A goniophotometer is a system to measure the luminous intensity of the source (or illuminance from the source at a given distance) in many different directions from the source. Compared with the sphere method, the goniophotometer method is theoretically free from errors due to differences in intensity distribution of the light source under test. It is applicable to acquire the luminous intensity distribution, luminous flux, spatial color distribution, and luminance distribution of lamps and luminaires.

  • High Accuracy Spectrophotocolorimeter

    LMS-3000 - Lisun Electronics Inc.

    • Measure and display the relative spectral power distribution (UV-VIS-NIR) P(λ), chromaticity coordinate, correlated color temperature, rending index, color difference, peak wavelength, luminous flux, luminous flux efficiency and photometry parameters of light source and light material under the control of general PC. • Automatically adjust high-voltage, it not only shortens the measurement time, but also reduces the wear and tear of the instrument • Simultaneously measure the temperature in both environment and integrating sphere to make the data more visually and reliably • Figure of chroma and color difference in test report can be exchanged freely • Color display and print. The relative spectral power distribution (UV-VIS-NIR) P(λ), reports both in English. RS-232-C interface, compatible with all kinds of computer • LSP-500 AC Power source PC RS-232-C interface. compatible with all kinds of computer • Range of wavelength: 380nm~780nm(Special:200nm~780nm) • Accuracy of wavelength: ±0.2nm • Repeatability of wavelength: ±0.1nm • Accuracy of chromaticity coordinate: ±0.0003(under standard illuminate A) • Spectrum sample interval: 5nm(Special order:1nm) • Luminosity linearity: 0.3% • Accuracy of luminosity: 1 class • Correlated color temperature measure range: 1500K~25000K • Accuracy of CCT: ±0.3%(under standard illuminate A) • Accuracy of rending index: ±(0.3%rd±0.3) • Environment temperature measure range: -10℃~80℃ • Temperature measure range(In sphere): -10℃~100℃

  • Signal Analysis

    Cross-Spectrum FFT Analysis - ZETLAB Company

    The program Cross narrow-band spectrum is used for evaluation of the interrelation between the signals’ parameters obtained from the two primary transducers installed at various parts of the controlled object. This program can be used for detection of noise source location, for sound absorption level evaluation and the researched object acoustic properties control, for evaluation of space-time distribution of the directional energy flux (Poynting vector), for the ground cross-section FR characteristic evaluation (Nakamura method), etc.

  • HF Measurement from 1 MHz to 10 GHz

    Frequency Master IV - ROM-Elektronik GmbH

    Based on a completely new method of signal analysis, ROM-Electronics measuring devices enable high-frequency and EMC measurements at a spectacular price.Finding sources of interference and their causes, determining power flux density, measuring and evaluating even the most complex signal forms - all this is easily possible with ROM-Electronics measuring devices.And by using our professional PC evaluation software you can increase the performance and functionality of your Frequency-Master IV even more!