  • Transformer Winding Resistance Meters

    TWA Standard Series - Amperis sl

    The TWA standard series instruments are designed to measure the resistance of six coils and simultaneously analyze the three-phase tap changer on load of the primary and secondary transformer coils (provided by model TWA40). This is done in a single cable configuration, with test currents up to 40A. Each transformer configuration has a special measurement algorithm that is optimized for rapid stabilization of test results. The TWA instruments generate a true DC current without ripple. Both current injection and magnetic circuit energy discharge are automatically regulated.

  • Surge Voltage Generator

    SSG 2100 - BAUR Prüf- und Messtechnik GmbH

    Cable fault location with the BAUR SSG 2100. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* Automatic discharge unit

  • Surge Voltage Generator

    SSG 1100 - BAUR Prüf- und Messtechnik GmbH

    Cable fault location with the BAUR SSG 1100. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* Automatic discharge unit

  • Surge Voltage Generator

    SSG 1500 - BAUR Prüf- und Messtechnik GmbH

    Cable fault location with the BAUR SSG 1500. Surge voltage generators are used for pre-location and pinpointing of high- and low-resistive as well as intermittent faults in power cables. The energy stored in a high-voltage capacitor is released at regular intervals or as DC voltage. The thus generated acoustic signal at the fault position can be recorded with a ground microphone and a universal receiver.* High surge voltage up to 32 kV* Continuously adjustable voltage* Voltage monitoring through kV meters with 3 measuring ranges* Automatic discharge unit

  • Inrush Current Generators for Zno Production Line

    Shanghai Guantu Technology Co., Ltd.

    Inrush Current Generator Standard: IEC61008, IEC61009, I61051/61643, ANSI C62.31, C62.33, C62.35, TU K20, K21, K44, K45, UL943Inrush Current Generator Features1. LCD screen display, built-in computer control, man-machine dialogue, easy to operate.2. Program-controlled high-voltage power supply, high voltage stability and precision3. Imported non-inductive high-power resistors are used to ensure the consistency of surge waveforms4. The main switch adopts electronic switch discharge mode, and the output polarity is automatically switched

  • Vacuum Degree Tester

    VC-VII - Xi'an Multipower Technic Co.,LTD

    VC-? vacuum degree tester is the seventh generation of the VC series and inherits the previous functions. The LCD is designed on the panel for users. The number of curves and the corresponding model of the vacuum interrupter are stored in the tester; the user can perform the test without instruction. The tester stored 43 pcs of update curves of interrupters that are corresponding to more than 300 types of overseas and domestic vacuum interrupters. It displays the waveforms of the leakage current and ionization current, from which the clients can judge there is the rod discharge or not in the ionization current.

  • Dielectric Loss Tangent Testing Instruments

    Soken Electric Co. Ltd

    Insulation materials in electrical equipment are used between a pair of electrodes; therefore it can be expressed as capacitors. Applying AC voltage to a capacitor with insulation materials causes an energy loss due to the leak current, the dielectric polarization, and the partial discharge. Because of this, the phase of the capacitor current is more delayed than that of a zero-loss current (reactive current) flowing in an ideal insulation material. The delay angle is called "Dielectric Loss Angle", and the tangent is "Dielectric Loss Tangent" (tanδ). Please refer to the technical guide explained in detail.

  • High Level of Customization at an Affordable Price

    TLP - Impulse Semiconductor Inc.

    The Impulse transmission line pulser (TLP) discharge networks are easily integrated with other instruments for a custom system matched for your device and process applications. Specifications include 1-10 nanosecond rise times, up to 40 amps peak, for 10-500 nanosecond pulse widths. It is a proven design incorporating 15 years of hardware and device development experience. Reliable performance over hundreds of processes, and thousands of products. All TLP systems are built by special request, contact us with your specifications or application.

  • Protector Conductor Test / Ground Continuity Test / Ground Bond Test

    LXinstruments GmbH

    Testing the protective conductor is indispensable for assemblies, devices and systems of protection class I because it reduces the risk of life-threatening electrical accidents.The test checks whether the protective earth (PE) fulfils the criteria specified in the standards and can correctly discharge the current occurring in case of a fault.The ground continuity test checks whether the protective earth conductor is connected continuously to all metallic enclosure parts that can be touched by the user. The test can be carried out with low currents and voltages (simple continuity test).

  • Digital (1kV below) Insulation Tester

    2751 IN - Standard Electric Works Co., Ltd

    ● Timer for test function (count 3-5 minutes).● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● 3½ digital LCD (2000 counts).● 68 × 34mm (2.677” × 1.338”) large LCD display.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA load.● 200mA short circuit testing current for continuity.● External voltage warning indication.● Fuse protection.● Data hold function● Auto power off function.● BS 16 edition.

  • Digital (1kV below) Insulation Tester

    1160 IN - Standard Electric Works Co., Ltd

    ● Measures insulation (MΩ), Continuity (Ω) and AC voltage.● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● 3½ digital LCD (2000 counts).● 68 × 34mm ( 2.677” × 1.338” ) large LCD display.● LCD backlight display.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA load.● 200mA short circuit testing current for continuity.● Auto ranging.● Fuse protection.● Data hold function.● BS 16 edition.

  • Digital (1kV below) Insulation Tester

    1161 IN - Standard Electric Works Co., Ltd

    ● Microprocessor-controlled.● Measures insulation (MΩ), Continuity (Ω) and AC voltage.● Three insulation test voltages(DC V) : 250V, 500V, 1000V.● 3½ digital LCD (2000 counts).● 68 × 34mm (2.677” × 1.338” ) large LCD display.● Waterproof design, protection class : IP54.● Automatic circuit discharge.● Test insulation at rated voltage into a 1mA load.● 200mA short circuit testing current for continuity.● Auto ranging.● Fuse protection.● Data hold function● BS 16 edition.

  • RS232 / RS485 / RS422 / Ethernet Surge Protectors

    CommFront Communications

    Our passive, rugged, industrial-grade RS232 / RS485 / RS422 / Ethernet surge protectors are designed for direct industrial DIN-rail mounting and they come with two (2) or three (3) stages of surge protection — Gas Discharge Tube (GDT), protection resistors, and Transient Voltage Suppressor (TVS) - for maximum protection. From 2-wire RS485, 4-wire RS422 / RS485, to 10 / 100 / 1000M Ethernet, CommFront's surge protectors safeguard your data lines and provide you with a peace of mind.

  • Lithium battery 128kWh Lifepo4 Battery pack 280Ah with BMS for Solar Energy Storage System

    SPVLI-128kWh - Zhejiang Sandi Electric Co., Ltd

    ESS lithium battery system is composed of lithium battery modules, BMS system, PV charge controller, AC/DC Charger, central control unit CCU, temperature detector, integrated structure and other parts; the solar panels in the system are battery storage and power for output; BMS module completes the detection and control of voltage, current, temperature, SOC, SOH and charging and discharging related parameters of power battery pack; PV controller and inverter realize bidirectional AC/DC function to meet the charging and discharging conversion demand of power battery pack; each detector is used to monitor the ambient temperature in real time to ensure the safety of the system.1. Standardized components, modular architecture, easy for expansion2. High energy density, small footprint, short construction period, strong environmental adaptability3. Battery module within the layered stack design, with more than 10 years of long design life 4. Long Cycle Life LiFePO4 Lithium ion Battery system from 20KWH—500KWH optional5. The use of international advanced Mitsubishi IPM module and intelligent power module, with high power fast adjustment capability6. BMS battery management system with SOC automatic calibration and high current active balance function, combined with the perfect operation control and management strategies to achieve accurate and efficient management7. The combination of software and hardware protection, with alarm protection and automatic diagnostic functions, improve the protection strategy to ensure safe and efficient operation of the system8. Product communicates with the monitoring platform in real time through RS232, CAN communication interface, and reports various records in time to ensure real-time monitoring of the battery pack of the monitoring platform9. PV charge controller adopts three charging stages (buck charging, equalize charging and float charging) which can maximize the utilization of PV modules and batteries10. Colorful LCD display all module working information and statusPerformance characteristics:Small size and light weight, Maintenance-free;Environmental protection and pollution-free materials, no heavy;Accurately estimate the state of charge of the battery pack, that is, the remaining power of the battery, to ensure that the power of the battery pack is maintained within a reasonable range;Built-in BMS management system with comprehensive protection and monitoring control functions;5" LCD screen display, easy to operate, can check the temperature, voltage, working status, discharge current, dynamic and static SOC algorithm of a single cell, local display of alarm info, alarm level distinction, accurate positioning of abnormal cells;Main control MCU can be centrally controlled and manage peripheral settings (AC charging module, inverter module, solar charging module) to adjust the charging current and voltage of peripheral devices according to the battery charging curve, making the system more reliable;BMS battery management system, with SOC automatic calibration and high current passive balance function, combined with perfect operation control and management strategy, to achieve accurate and efficient management;EMS energy management system, BMS with solar controller/AC charger, inverter centrally manages charge and discharge, effectively controls the charge and discharge current within the cell usage conditions, protects the cell and extend its service life;SpecificationLithium battery 128kWh Lifepo4 Battery pack 280Ah with BMS for Solar Energy Storage SystemModel SPVLI-128KWHType of cell LiFePO4 (Lithium iron phosphate)Battery cell configuration 3.2V 280AH 144PCSRated capacity (KWH) 128kwhNominal capacity (AH) 280AHNominal voltage (VDC) 460VOperating voltage range (VDC) 375-540VRecommended Charge Voltage (VDC) 504VRecommended discharge cutoff voltage (VDC) 382VRecommended charge current(A) 140AMax Charge Current (A) 280ARecommended discharge current (A) 140AMax Discharge Current (A) 280ACharge temp range 1~45℃Discharge temp range -10~45℃MPPT Solar Charge Controller InputMaximum. Input voltage of solar array(Vdc) <900VdcBattery system voltage 460VDCMaximum power of solar array 64KWMaximum charge current(A) 140AEqualization charging voltage (Vdc) 511.2VEqualize charging recovery voltage (Vdc) 486.72VOver voltage disconnect voltage (Vdc) 525.6VOver voltage recovery (Vdc) 518.4VWorking temperature -20~50℃Protection level IP20Communication interface CAN2.0, BMSDisplay 5" LCD, EnglishCooling system Fan coolingWorking Altitude (m) ≤3000mReference Weight (Kg) 1530KgReference size (W*D*H mm) 1200*1120*1950mm

  • High Performance High Power DC Electronic Load

    IT8900A/E Series - I-TECH Electronic Co., Ltd

    IT8900A/E series high performance high power DC electronic load provides three voltage ranges 150V/600V/1200V, stand-alone power from 2kW to 54kW. IT8900A/E series, with ultra-wide voltage and current range, controlled by an independent master unit. The power expands to 384kW by master-slave paralleling. Ultra-high power density, 6kW is with only 4U height. IT8900A/E series has eight (A series) / four (E series) working modes, faster loop response and current rising and falling speed, as well as dynamic mode, OCP test, OPP test, automatic test and battery test functions. Built-in CAN, LAN, GPIB, USB, RS232 and analog interfaces, etc., IT8900A/E series has full protection function, which can be applied to power battery discharge, DC charging station, on-board charger (OBC), power electronics and other power electronics products.