UHPS -
RARA Electronics Corporation
*Max. current limit 707A*Excellent short term stability*Low temperature coefficient of resistance (T.C.R.)*High current sensing & reference resistors in laboratories*Change - discharge test equipment for high capacity batteries*Current sources & laboratory power supplies
-
LCN -
Bitrode, Inc.
Full featured test system for quality control and R&DLife Cycle Testing: Perform charge/discharge cycling of batteries or modules to obtain charge and discharge capacity, energy and DC internal resistanceAutomotive Battery TestingStarting, Lighting and Ignition (SLI) TestingTraction Battery Testing
-
ELAK Private Ltd.
ELAK Battery Testers are high-rate discharge testers. These testers impose a load on the battery, which is equivalent to that drawn by the starter motor from the battery, while cranking the engine. The tester studies the drop in battery voltage & indicates the condition of the battery if it is capable of starting the engine or not.
-
TD 100 -
Scope T&M Pvt, Ltd.
TD100 is an innovative NDT - Non-Destructive Testing equipment, which detects, pinpoints and documents flash-arc corona and arcing partial discharge camera. Being with high sensitivity, it is a power tool to detect UV emission in full daylight with high signals from faraway and nearby sources.
-
PD Alarm -
IPEC Ltd.
The PD Alarm™ is an asset mounted device for indicating the presence of partial discharge in high voltage switchgear, ring main units (RMUs) and dry type transformers. Designed for use in small substations, the instrument can activate local and remote alarms in addition to local indication.
-
SGMF(T) Series -
Shanghai Jiuzhi Electric Co., Ltd.
Onsite mobile AC high voltage test systems are used for withstand voltage testing, partial discharge measurement, tan delta measurement to instrument transformers, GIS, GIL, switchgears and etc after they are installed onsite and for purposes of diagnostics in asset management up to 900kV/10A.
-
7500 -
Tokyo Electronics Trading Co., Ltd.
ESD test based on Human Body Model (HBM) and Machine Model (MM) is the most important reliability test among the Electro-static Discharge (ESD) test of the semiconductor device. Latch-up test, on the other hand, should not be omitted from the reliability test of the CMOS devices.
-
7000 -
Tokyo Electronics Trading Co., Ltd.
ESD test based on Human Body Model (HBM) and Machine Model (MM) is the most important reliability test among the Electro-static Discharge (ESD) test of the semiconductor device. Latch-up test, on the other hand, should not be omitted from the reliability test of the CMOS devices.
-
WIKA Alexander Wiegand SE & Co. KG
Discharges during switching operations in SF6 gas-filled plant lead, over time, to increased concentrations of toxic and highly corrosive decomposition products. The use of gas analysis instruments is absolutely necessary to monitor the concentration of harmful decomposition products, thus ensuring long-term plant safety. WIKA offers a complete product line for gas analytics with instruments for measuring individual decomposition products, through multi-analysers with pump-back functionality, to high-precision laboratory equipment.
-
BLU-A Series -
IBEKO Power AB
The battery capacity test is performed to determine the health of a battery. DV Power’s battery load unit BLU-A is a portable, powerful, and lightweight solution for battery capacity measurement. It is applicable to any battery string such as lead-acid, Li-Ion, Ni-Cd, etc., with up to 500 V battery voltage. As a special feature, BLU100L model enables the capacity testing of a single Li-Ion cell.The capacity test is performed in an accurate and user-friendly way. Also, it is in accordance with battery testing standards: IEEE 450-2010, IEEE 1188-2005, IEEE 1106-2015, IEC 60896-11/22, and other relevant standards.Battery load unit BLU-A enables setting discharge currents up to 240 A, with a resolution 0,1 A. Furthermore, if higher currents are required, BLU-A units can be connected in parallel, or additional BXL load units can be used.The instrument offers the best power-to-weight ratio in the market. BLU-A models start from 12,8 kg / 28.2 lbs and deliver up to 28,4 kW of power.The user can select three discharge modes:Constant current,Constant power,Constant resistance.Additionally, different battery duty cycles can be simulated using user-selectable discharge profiles.The instrument monitors discharge parameters in real-time during the capacity test. A 4,3-inch touch screen display shows battery voltage, current, elapsed time, and capacity during the entire test. Also, BLU battery load unit can be used with DV-B Win software. As a result of that, a user can see a detailed numerical and graphical presentation of key parameters and can create reports in various formats.Testing with BLU-A doesn’t require a disconnection of the battery from the testing equipment.
-
612 -
ACT Meters International Ltd
This digital battery tester is designed for testing 6V and 12V standby SLA, cyclic GEL and car FLOODED batteries. Simple in operation, the ACT 612 simulates a full 20 hour (C20) discharge test in seconds and displays the DC Voltage results and Ah capacity available.
-
Desco Industries, Inc.
Point-Of-Use Ionizer, Adjustable (30-100 PSI) Compressed Air IonizerNeutralize Electrostatic Attraction (ESA) to control contamination by dislodging dust and debris attracted by static electricity.Detachable 7'' long ESD Protective Flexible Hose with Thumb Button Designed to for a wide range of motion and simple operation.Adjustable Balance (20 Volts) with Less Than 1 Second Discharge Time At 6 InchMeets required limits ANSI/ESD S20.20 tested per ANSI/ESDSTM3.1 and ESD TR53
-
Liona -
BAUR Prüf- und Messtechnik GmbH
Cable testing and diagnostics with the BAUR liona. Liona is a portable online PD spot tester for measuring and locating partial discharges in cables and switchgear during normal mains operation. Liona lets you test cable systems and electrical equipment online without switching off partial discharge activities, and then generate trend analyses. Even a PD spot test (duration: 5-10 minutes) is capable of reliably assessing the current status of your system.* Automatic PD detection during normal mains operation (without switching off the cable route)* With DeCIFer technology: PD identification based on 500 million measurement results* Precise online PD mapping with PD transponder
-
EVd-40 -
NuVant Systems, Inc.
The EVd-40 Power Tester is a pre- and post-reconditioning tool for quality control of aftermarket HEV & EV battery production. The equipment integrates a “smart” charger (Sorensen XG 1700 or Kepco KLN 1500W) with NuVant Systems high power discharge electronics. The "power test" discharges battery packs at high power (10,000 watts), while tracking module voltages. The software monitors up to 40 module voltages at a time, identifying any weak modules. The "smart" charger performs charging constant current (CC), constant voltage (CV) and complex mixed mode constant current – constant voltage (CCCV) charging protocols at voltages up to 600 V. This enables recharge of any type of rechargeable battery.
-
AD-2025 -
ADEX Urzadzenia Pomiarowe
Measuring voltage control during measurement, Insulation measurement up to 400 G W. Elimination of trough resistance insulation ? 3 connectors measurement method, Autoranging, Auto-Discharge facility safely discharges the connected circuit after a test, 5 minutes, 1 minute at will shorter measurement,