  • Battery Load Banks

    Kongter Test & Measurement Co., Limited

    Kongter offers many different models of battery load units for real capacity test in various industries. With our customized solution, users of different applications will find their exact models as per their needs. With its optional DAC (Data Acquisition Case), you could easily monitor voltage of each cell on PC during battery discharge test.

  • Battery Fuel Gauge

    Global Digital Instruments, LLC

    SenDEC Battery Fuel Gauges are designed to accurately monitor the charge capacity of lead acid batteries. SenDEC fuel gauges can be used to monitor DC powered equipment such as fork lifts, golf carts, floor care equipment, and any other battery powered equipment. Three battery discharge profiles are standard, plus custom profiles, and a lockout option.

  • CATx Surge Protector

    SP-CAT5-6V - Network Technologies Inc

    Protects sensors running on CATx unshielded twisted pair (UTP) cable against the effects of electrostatic discharge, faulty wiring and lightning. The use of two protectors on each end of the line will provide increased protection for each end against surges. Protected pins: (1,2) (3,6) (4,7) and (7,8) pass through. Impedance: 85 to 115 Ohms. Surge suppression: 22Vpeak @ 100A 10/1000µs. Maximum continuous voltage: 6Vpeak. Dimensions WxDxH: 1x3.6x0.9 in (25x91x23 mm). Regulatory approvals: GR 1089, NEC 800.100 and 830.100, ITU 703, UL94 V0 Flame Rated.

  • High Frequency Current Transformer

    HFCT Ø 140mm - Techimp HQ S.r.L

    Techimp Clamp High Frequency Current Transformer model 140 is an inductive sensor for partial discharge measurements. It is suitable for online /off line PD tests on : large diameter cables ; grounding rod bar ; etc. A TNC termination is available to connect the Clamp HFCT 140 to the TechImp PD analyzer : PDCheck , PDBase etc. The arrow indicates the requested input current (Iin) direction to get coherent output voltage (Vout) polarity respect to ground. When the sensor is installed with the arrow directed to ground, the detected voltage signal (Vout) has the same phase of the input current (Iin).

  • Sensor Technology

    Power Monitoring and Diagnostic Technology Ltd.

    PMDT is the only manufacturer to utilize all 5 types of online partial discharge sensor technology. Using multiple sensing methods ensures that PD activity is always discovered, located, and characterized. PMDT's handheld PDetector and PDStar units have more capability than the high-end diagnostic equipment of the past. The small handheld, battery powered unit can completely perform the test and analysis without the need of a PC. PDetector, PDStar, and PDiagnostic instruments feature high-resolution phase-resolved analysis of PD signals (PRPD and PRPS) in real time, so you get your test results instantly!

  • Surge Generators

    K&S Engineering and Scientific Ltd

    The instrument is fully enclosed in a robust all steel enclosure mounted on castors and fitted with carrying handles. The control panel forms the top of the case, it is finished in high gloss light blue stoving with cutter engraved labelling, and is protected by a detachable lid. The EHT outlet is of a recessed type designed to prevent accidental contact with high voltages. Surge repetition is electronically controlled from 0 to 10 seconds, a single surge or a train of pulses can be selected by a panel mounted switch. Automatic discharge of the instrument is achieved by a gravity operated switch which is released on switching 'OFF' the instrument or on disconnecting the supply.

  • Charge Plate Monitor

    Kasuga Denki, Inc.

    The electrostatic resistance of electronic devices is declining, and the number of ionizers installed is increasing. Ionizers cause deterioration of static elimination performance and imbalance of ions due to dirt and wear of the discharge electrode needle. Charging of electronic devices is also caused by ion blow. of an ionizer that is out of balance due to dirt and wear, and reaches a level that destroys advanced electronic devices.The atmospheric ion monitor measures the potential of the charging plate (detector), which has almost the same capacitance as the device's ground capacitance , with high accuracy, and is the most suitable measuring instrument for checking the effect when installing the ionizer and for daily management.

  • Battery Test Systems

    Intepro Systems

    The Intepro’s battery test systems are configurable systems designed to test the latest Lithium Ion batteries and other high power density batteries and chargers. Combining high resolution, high powered charge and discharge systems, Intepro IBT line of battery test systems link to the battery management through the bus communication and fail-safe external monitoring of key battery parameters.

  • Analyzers

    BA500 Series - Battery Metric

    The BA500 analyzers are high performance battery analyzers with charge and discharge capabilities. The analyzers connect to your computer via USB and the BA500WIN software program is used to control the analyzer and battery under test. This system has a fast data collection system allowing you to collect and view as much data as required. Once you collect this data you can graph, analyze & save it.

  • Insulation Resistance Meter

    AMIC-15k1 - Amperis sl

    *The partial discharge indicator PDI.*Diagnosis of insulation systems based on standard measurements of IR, DAR, PI, SV, RT, DD*Allows to test the electrical durability of the tested object - indication of breaking voltage.*The high resistance to electromagnetic interference ensures uninterrupted operation in power plants and near high-voltage transmission lines up to 1200 kV AC and 500 kV DC.

  • Electrical Safety Testers

    Kikusui Electronics Corp.

    a high performance electrical safety analyzer that complies to a wide range of universal standards. Hipot, Insulation Resistance, Ground Bond, Leakage Current (touch current and protective conductor current) and partial discharge can all be tested. A total of 6 models are available for standard compliance tests in a wide variety of applications including R&D, quality assurance manufacturing lines and laboratory tests.

  • PD Measurement Devices

    Power Diagnostix Systems GmbH

    The ICMsystem is a digital partial discharge detection system. The instrument is completely controlled by software using a GPIB, USB, TCP/IP, GSM Modem, fiber optic or direct serial link. It can be expanded to up to 10  true-parallel acquisition channels, while offering all features of the single channel  ICMsystem. It is designed for acceptance tests on large power transformers and other application requiring parallel acquisition.

  • Sixteen Channel 12-Bit Analog Input/Output Cards

    PCI-A12-16A - Acces I/O Products, Inc.

    Model PCI-A12-16A is a multifunction, analog-to-digital, digital-to-analog, and digital I/O card. It accepts up to 16 single-ended inputs or eight differential inputs. Inputs are protected against over-voltage conditions up to ±35 volts and typically survive static discharges beyond 4000 volts. Conversions can be initiated in any one of three ways: (a) software command, (b) external start commands, or (c) on a timed basis using on-board programmable counters. Converted data may be transferred to the computer by one of two software selected methods: (a) polling for the end-of-conversion signal, or (b) by generating an Interrupt when the end-of-conversion signal occurs.

  • All in one system 32KWH LiFePO4 Lithium Battery with AC Charger and 15KW Inverter for mobile vehicle application

    SPVLI-32KWH-INV15KW - Zhejiang Sandi Electric Co., Ltd

    Our All in one system 32KWH LiFePO4 Lithium Battery with AC Charger and 12-15KW 120/240V Inverter for mobile vehicle application ESS including LiFePO4 Lithium Battery with BMS, off grid pure sine wave inverter, AC/DC charger.All-in-one design, high integration and space saving installation;Using high-performance lithium iron phosphate cells, laser welding, good cell consistency, designed service life of more than 10 years; Charging and discharging are controlled separately, which is convenient and reliable to control charging and discharging. The discharge port will not be disconnected when over-charging, and the charging port will not be disconnected when over-discharging, the system has good stability;Master-slave mode, passive equalization, can manage the equalization resistance, can set the equalization start voltage difference, and monitor the equalization resistance temperature, more intelligent and safe, and reduce the impact of barrel effect on system energy storage;BMS adopts NXP(USA) automotive-grade high-performance chips, with strong anti-interference, good reliability and wide temperature range;CAN2.0 communication interface, has the advantages of strong real-time performance, long transmission distance, strong anti-electromagnetic interference ability;System parameters can be set through the host computer, such as fan start/stop temperature, charger maximum current setting, charge and discharge current correction, SOC correction, with insulation leakage detection function to prevent oil leakage and short circuit of the cell;Integrate Solar charge controller or AC charger optional, BMS communication control, more safe and reliable;Cell temperature management, can be automatically controlled with the air conditioner heater according to the cell condition to make the cell works at the most suitable temperature, and can be linked with the fire protection system as neededModel SPVLI-30KWH-INV12KWIsolation mode Low Frequency TransformerInverter PartBattery Input Rated Voltage (Vdc) 307VDC Voltage range (Vdc) 278-400VAC Output Rated output power 12KW Output waveform Pure Sine Wave Rated Voltage 120/240VAC Phases Split phase + N + PE Rated current (A) 50A(Phase Current) Frequency 60Hz Power Factor (PF) >0.95 Inverter Efficiency >92% Display LCD Overload Ability 150%, 35 secondsAC-DC Charger PartAC Input Voltage range(Vac) 180-240VacDC Output Rated voltage(Vdc) 330Vdc Rated current(A) 20ALithium Battery PartCell/Number 105AH/96PCSRated voltage 307VMax charge current 20AMax discharge current 100ACharge temperature range 0℃ ~ 50℃Discharge temperature range -20℃ ~ 50℃Cell charge end voltage 3.6VCell discharge end voltage 2.7VProtection Function Protection Input reverse polarity, under voltage, over voltage, output over-current, short circuit, overheating etc. Cooling method Fan-cooledDegree of protection IP20(indoor)Mechanical Dimension Depth* Width * Height 645x891x767mm Weight (Kg) 378Kg

  • Cable Diagnostic Tools

    High Voltage Inc.

    For non-destructive diagnostic testing to determine the quality of a cable’s insulation with minimal risk of failure, HVI recommends tan delta and partial discharge testing for valuable diagnostic data about cable insulation integrity. Both use a VLF source to perform elevated voltage, off-line testing. Tan delta testing measures insulation health, while PD identifies specific problem areas and assesses their severity.