Showing results: 3526 - 3540 of 5224 items found.
-
Praxsym
Low Noise Pre-Amplifier and companion external low noise amplifier (LNA) are used to amplify low level microwave signals. The Pre-Amplifier contains an AC/DC power supply, internal low noise amplifier, and a bias tee to source a DC bias voltage on the RF input connector.To overcome cable loss between the test antenna and the Pre-Amplifier assembly, a remote low noise amplifier (LNA) is mounted directly onto the 10 GHz antenna. A bias tee inside the Pre-Amplifier chassis powers the remote LNA through the coax cable interconnecting the pre-amplifier and the 10 GHz test antenna.
-
Virtins Technology
1) Measurement microphone and its accessories (a windshield and a microphone clip)2) XLR-to-USB Converter3) USB cable (1.5 m) 4) CD (contains the copy-protected Multi-Instrument Software) 5) USB hardkey (contains a Multi-Instrument Standard License)6) Audio Test CD (contains a list of audio test tones and noises) (AudioTestCD.zip or AudioTestCD.rar)7) 1/8” TRS cable (1.8m) 8) Black Soft Pouch Case 9) Individual Sound Level Calibration Data 10) Individual Microphone Calibration Data (only provided in RTA-168B)11) A small microphone stand
-
Educated Design & Development, Inc.
Up to 8 resistance reading channels, 4-wire methodUp to 12 temperature reading chanels, use of Type K, 24 AWG, Teflon thermocouplesIn the Box:8 - data cable (Cat5e) to connect the isolation modules to the Resistance Reading Channels8 - Isolation Module connected between the HOT-30 and EUT (Equipment Under Test) to isolate high voltage8 - Banana Jack Sets (2 red, 2 black), to replace Kelvin Leads in tight places8 - Kelvin Probe Set12 - 72 inch K Type Thermocouple1 - USB2.0 Type A (standard) to Type B USB cable
-
TPA-95 -
High Power Pulse Instruments GmbH
*Flexible pulse force, pulse sense combined TLP probe arm kit based on TPA-95L and TPA-95R*Compatible with typical standard micropositioner mechanical interfaces*4.7 kΩ pulse sense voltage divider, which results in a voltage transfer ratio of (4700 + 50)/50 = 95 : 1 into 50 Ω*Variable probe pitch configuration*1 m flexible 50 Ω cables with SMA connector for pulse sense*0.1 m flexible 50 Ω cables with SMA connector for pulse force*Tungsten probe tips*Can be used for chuck backside grounded TLP measurements
-
PD-SGS -
BAUR Prüf- und Messtechnik GmbH
Quick identification of PD activities in switchgear and cable accessories. The BAUR PD-SGS handheld online PD detector is used to conduct rapid initial tests for PD activities on live switchgear. Potential weak points are immediately signalled acoustically and numerically.* Initial rapid condition evaluation of switchgear and cable accessories during mains operation* Ideal for quick checks of MV and HV switchgear* Two integrated sensors:TEV sensor records PD on the surfaces of switchgearsAcoustic sensor records PD inside switchgears* Greater safety for test personnel switchgear tested for safety risks before starting work
-
Rockwell Automation
Our Connection Devices include Network Media for Ethernet, ControlNet™, DeviceNet™, Power Media, and Safety Connection Systems. We offer many products for DC Micro (M12), AC Micro (1/2), MiniPlus (1, 1-1/8), Mini (7/8), Pico (M8), and M23: cordsets, patchcords, V- and Y-cables, splitters, field attachable connectors, and receptacles. Our I/O Wiring Systems include interface modules and cables that connect through pre-wired cables to digital and analog I/O. We offer several IEC and NEMA terminal blocks to meet your needs.
-
FW3 -
North Atlantic Industries
The FW3 function module provides IEEE 1394b/AS5643 (Mil1394) support on each of its three nodes, which are configured as 2 nodes with 3-ports and 1 node with 2-ports. AS5643 defined flight ready robustness and active transformer isolation to enable longer cable lengths (20 meter) between nodes. Together these standards provide the deterministic and redundant communications protocol required for Vehicle System (Flight Control) Networks. The FW3 multiple ports per node configuration allows the user to create tree, daisy-chain and looped topologies needed to optimize cable length and weight while creating redundancy.
-
N1055A -
Keysight Technologies
Bandwidth options: 35 or 50 GHz (upgradable)Edge speed (10-90%, typical): 18 ps (35 GHz) or 7 ps (50 GHz)Channel options: 2 or 4 per module (upgradable) with independent skew control and up to 16 channels per 86100D mainframe Ultra-thin remote head: 1.6 m phase-stable cable, 2.92 mm (35 GHz) or 1.85 mm (50 GHz) connectors, and integrated 67 GHz diode limiters for ESD/EOS protection TDR fixture de-embedding removes effects of fixtures, cables or probes connected between remote heads and DUT
-
Panther4HT Master- Slave DSU -
Qmax Test Technologies Pvt. Ltd.
The Master- Slave DSU based Panther4HT Wire Harness tester is designed for testing and verifying electrical connections in a cable, harness, backplane or any other wired assembly. It offers unique Qmax MASTER - Slave concept and SATELLITE UNIT Options to avoid looping back of cable to the ATE. All Satellite Units communicates the measurements through LAN interface which is very useful for on-board applications in Aircrafts / Ships and similar applications where large cable looms are used. This innovative concept will eliminate the long adapter cables and hence storing, maintaining and re work of these kind of cables are avoided. Furthermore single Master Controller Unit (MCU) is used to control not only all the satellite units , but also communicate with all satellite units through Ethernet Communication port. A single reference Cable is used to link the all the satellite units with the Master Controller in controlled loop manner is a value add to the product.
-
72-8495 -
Tenma
Compact 2-in-1 unit provides standard digital multimeter functions, as well as pin configurations on network and voice cables. Dual pinout indicator provides sequential verification of each pin on a network cable, and the included remote terminator allows testing of cables which are already installed. Digital multimeter measures AC/DC volts and amps, resistance and diodes, and provides audible continuity test.
-
P50 -
Beijing GFUVE Electronics Co.,Ltd.
mv AC clamp on current probe has 1mV voltage or 1mA current output, can measure cable and bus bar, max current is 1000A, high precision, can be used to monitor power quality. Perfect material permalloy core.
-
Suparule Systems Ltd.
The Sensorform Range of Earth Fault Indicators detects earth faults & short circuit faults on underground cables. A number of options are available for enclosure type, power source, indicator type, reset method, trip-level selection, and remote indication.
-
4613 -
VECTOR Electronics and Technology, Inc.
62 contacts (31 each side) on 0.100" centers. 3-Hole Solder Pads for interconnecting multiple component leads.I/O mounting area for 37-pin D-sub and ribbon cable connectors. Mounting bracket and hardware kit included (P/N HD36B).
-
C-Sense -
Precision Measurement Engineering, Inc.
The C-sense Logger is a submersible, portable device that records pCO2 over a period of time. Data are collected at a variety of sample rates, selected by the customer, and stored internally. Data are offloaded to a computer via a USB cable for easy viewing and analysis.FEATURES
-
G10 - 10 -
Virginia Panel Corporation
This 10 Module Solution provides reliability while simultaneously engaging up to 2,400 signal contacts. The adaptable G10 integrates a wide variety of I/O options in various module configurations. The contacts are incorporated into cable assemblies for specific instruments.