Filter Results By:

Products

Applications

Manufacturers

CAT

Computer Aided Test


Showing results: 16 - 30 of 276 items found.

  • PCB Adapter, ITA, SIM, VTAC, 34 Positions, To (2)  USB 5 Gbps (USB 3.0, USB 3.1 Gen 1, USB 3.2 Gen 1) and (4) Cat 6

    510171114 - Virginia Panel Corporation

    PCB Adapter, ITA, SIM, VTAC, 34 Positions, to (2)  USB 5 Gbps (USB 3.0, USB 3.1 Gen 1, USB 3.2 Gen 1) and (4) Cat 6

  • Circuit Breaker Analyzer

    CAT Standard Series - Amperis sl

    The CAT Standard series circuit breaker analyzers & timers are stand-alone or a PC-controlled digital instruments for circuit breakers condition assessments. The timing channels record closing and opening of the arcing, resistor, and auxiliary contacts. CAT Standard series records graphs of both, trip and close coil currents and displacements of the HV and MV circuit breaker moving parts. The main contact channels can also measure the resistance value of the pre-insertion resistors (if present in the circuit breaker). Test results can be downloaded to a USB memory stick or saved to internal memory. The CAT Standard series internal memory can store up to 500 test results (numerical and graphical data). Test results can also be printed on the 80 mm (3.15 inch) thermal printer (optional accessory) in tabular and graphical form. CAT Standard series provides an easy selection of different operational modes:

  • Analyzers and Timers

    CAT Advanced Series - Amperis sl

    Description The Advanced CAT Series Analyzers and Timers are stand-alone or PC-controlled digital instruments for circuit breaker status evaluation. Timing channels record arc closing and opening, resistance and auxiliary contacts. The main contact channels can also measure the resistance value of pre-insertion resistors (if present in the breaker). The advanced CAT series records graphs of the opening and closing coil currents and the movements of the moving parts of the high and medium voltage circuit breaker. Test results are printed on the 112 mm (4.4 inch) thermal printer (optional accessory) in tabular and graphical form. The advanced CAT series provides easy selection of different operating modes:

  • Line Tester

    CAT 1 TEST - Monacor International GmbH & Co. KG

    Line tester for continuity testing of Cat 5, Cat 6 and ISDN network cables*Connection test with LED display for 8 individual wires and shielding*Continuity, miswire, open, short, crossover, and ground detection*Connector compatibility with the following modular plugs: RJ45 (8P8C), RJ12 (6P6C), RJ11(6P4C, 6P2C)*Network standards supported: Token Ring, 10Base-T, 10Base-T2, 285A, TIA568A/568B*Separate receiver for particularly long and complex cables*The main unit and separate receiver can be attached to one another using a guide rail on the side*Power supply via 9 V block battery (not included)*Supplied with protective bag

  • Circuit Breaker Analyzers & Timers

    CAT Standard Series - IBEKO Power AB

    Circuit breakers are being tested during manufacturing, commissioning or maintenance stages. The most basic test requires timing measurement using circuit breaker timer. Their primary role is timing and motion measurement of medium and high voltage circuit breakers. Devices from CAT Standard series have suitable application in:electric power generation,distribution system,part of the electric power transmission system,contractors testing,and industrial environments.CAT Standard series meets the requirements of an easy to use circuit breaker timer and analyzer with an attractive price. Furthermore, they are portable and lightweight (weighs only up to 7 kg). Finally, the plastic case is unbreakable and has IP67 protective rating when the lid is closed.CAT Standard series includes five models:Three circuit breaker timers – CAT03, CAT31, and CAT61Two circuit breaker analyzers – CAT34 and CAT64CAT03 is a basic model intended only for timing measurement of main contact operations on the circuit breaker with one break per phase. Unlike CAT03, CAT31 has the possibility of circuit breaker operation initiation, coil current measurement, and auxiliary contact timing measurement. CAT61 differs in comparison to CAT31 by its ability to measure up to two breaks per phase.CAT34 and CAT64 are more advanced compared to CAT31 and CAT61, respectively, since they have additional analog channels. Also, they have the possibility of a travel curve recording.A user can download the test results to a USB memory stick or save it to internal memory. The CAT Standard series internal memory can store up to 500 test results (numerical and graphical data). Optional thermal printer prints test results in tabular and graphical form on 80 mm (3.15 inch) paper rolls. CAT Standard series instruments are compatible with DV-Win software. It provides full control of all CAT functions from a PC, as well as acquisition and analysis of test results.

  • Circuit Breaker Analyzers & Timers

    CAT Advanced Series - IBEKO Power AB

    DV Power circuit breaker analyzer and timer utilizes the latest technological enhancements for safe and fast testing of circuit breakers. The sophisticated design ensures efficient and reliable operations in high-voltage substations and industrial environments.The CAT Advanced series are stand-alone or PC-controlled digital instruments for a circuit breaker testing. The timing channels record closing and an opening of the arcing, resistor, and auxiliary contacts. Also, the main contact channels can measure the resistance value of the pre-insertion resistors (if present in the circuit breaker).With CAT Advanced series instruments, it is possible to record graphs of open and close coil currents. Furthermore, it records displacements of the HV and MV circuit breaker moving parts. Test results can be saved via USB, PC or be printed via 112 mm (4.4 inches) thermal printer (optional accessory) in tabular and graphical form.A circuit breaker test consists of different operational modes and CAT Advanced series supports:Open (O)Close (C)Reclose (O-0,3s-C)Trip free (CO)O-0,3s-COOpen-Close (O-C)Close-Open (C-O)Open-Close-Open (O-C-O)First trip (O)Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by sensing a breaker’s contact position.The auxiliary inputs are used to monitor dry and wet auxiliary contacts. The six coil control analog channels measure and record coil currents simultaneously (OPEN and CLOSE), up to 35 A AC/DC.The additional six voltage analog channels have four selectable voltage ranges available (±1 V, ±5 V, ±60 V and ±300 V AC/DC).A built-in micro-ohmmeter generates up to 500A true DC ripple-free current with an automatically regulated test ramp that provides performing static and dynamic contact resistance measurement.Three transducer channels provide a measuring displacement of the circuit breaker moving parts, contact wipe, over-travel, rebound, damping time and average velocity. Also, a user can connect either an analog or a digital transducer to these universal channels.

  • Double Display TRMS Multimeter with USB Interface

    VA42 VA42R VA42RP - Shanghai Yi Hua V&A Instrument Co., Ltd. CO.,LTD

    This instrument complies with IEC 61010-1:2001, CAT II 1000V and CAT III 600V overvoltage standards. See Specifications.

  • 3 Phase Meter - Anti-Clockwise

    135012 - Silvertronic Ltd.

    IEC 1010 Rating: 1000V Cat III/600V Cat IV Double/Reinforced Insulation Features: For Use In The Installation and Operation Of 3 Phase Equipment.

  • 3 Phase Meter - Clockwise

    135007 - Silvertronic Ltd.

    IEC 1010 Rating: 1000V Cat III/600V Cat IV Double/Reinforced Insulation Features: For Use In The Installation and Operation Of 3 Phase Equipment.

  • Voltmeter

    KT750 - Ketai instrument (kunshan) Ltd.

    0~600V AC and DC voltage automatic discrimination Light, vibration CAT III 1000V CAT Ⅳ 600V Your OEM/ODM Partner For Quality

  • Voltmeter

    KT7100 - Ketai instrument (kunshan) Ltd.

    0~600V AC and DC voltage automatic discrimination Light, vibration CAT III 1000V CAT Ⅳ 600V Your OEM/ODM Partner For Quality

  • Multi-Function Oscilloscope

    SBS Storage Battery Systems, LLC

    The SBS-700 o-scope/meter helps minimize your project risk by providing reliable, accurate data or waveform capture and the complete view of logic tools. 600 V CAT III & 1000 V CAT IV DMM / 300 V CAT III O-ScopeEfficiency measurement and ripple noise measurement

  • Replacement Bulb for Continuity Tester

    69131 - Klein Tools, Inc.

    Replacement bulb for Cat. No. 69133

  • Voltmeter

    KT7200 - Ketai instrument (kunshan) Ltd.

    0~600V AC and DC voltage can automatically distinguish the light and vibration on and off buzzer CAT III 1000V CAT Ⅳ 600V Your OEM/ODM Partner For Quality

  • Circuit Breaker Analyzers & Timers

    CAT Handheld Series - IBEKO Power AB

    When it’s not practical to use conventional robust circuit breaker analyzers, a handheld circuit breaker analyzer and timer may come handy. DV Power has developed a unique CAT Handheld series. It is specially designed for testing of circuit breakers with one break per phase. Their compact and ergonomic design can provide a wide range of features and reliable operations in low, medium and high-voltage substations or in industrial environments.CAT Handheld series consists of two models, CAT-P and CAT-H. Both of them have a large (5,7 in) colored touch screen display. Because of that, test results are visible in dark places as well as in bright sunlight.Powerful internal Li-Ion battery of the instruments can last up to 8 hours of testing without recharging.CAT Handheld series records:main contacts operating times,contact synchronization,sequence time,a resistance of pre-insertion resistors,open and close coil currents,main contacts bounce time,auxiliary contact time,DC Voltage.Multiple operations, such as Open-Close and Open-Close-Open, can be initiated by using a predefined delay time or by triggering signal from current clamps connected to circuit breaker coil.CAT-H is capable of performing a coil control, while this feature is optional at CAT-P instrument. In contrast to CAT-H, CAT-P instrument can execute “First Trip” test.Both instruments display numerical and graphical results. Because of that, a user can easily overlay up to 4 records in the graphical form and make a quick on-site analysis of potential defects.A user can download test results to a PC via Bluetooth interface for more detailed analysis using DV Win software.