  • Clamp Meter

    KT-3500 - KILTER ELECTRONIC CO.,LTD

    • Non - intrusive AC and DC current measurement• 10mA resolution• Average responding, RMS calibrated• Auto ranging /Auto zeroing• Data Hold • Low battery indicator• Auto Power OffMeasuring Range: 0 - 500A DC or ACAuto ranging : 50A/500AResolution: 10mA in 50A range, 100 mA in 500A rangeBasic Accuracy: ±1.3% rdg ±5 digitsTemperature coefficient: ±0.05% of rdg /°CFrequency range: DC in DC: 40 HZ to 400 HZ in ACOverload capacity: 500 ADielectric strength: 3.7 KV RMS.50 Hz 60s(EN61010-2-032 Cat III, 300V Pollution Degree 2)Operating Temperature: 0°C to +50°CBattery removed: -20°C to +60°COperating Humidity : <80%RHPower supply: 9V alkaline batteryBattery life: 20 hours dependent duty cycle Display.: 5000 countDimensions: 184×71×31mmMax jaw capacity: 21mm ø CableMax jaw opening: 25mm

  • Digital H.V. Insulation Tester(15kV)

    7016 IN - Standard Electric Works Co., Ltd

    ● Protection class: IP66 (Lid closed)● Test insulation resistance up to 30TΩ (30000GΩ).● Short-circuit current up to 5mA● Microprocessor controlled.● 30 insulation test voltages : 500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV, 3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV, 6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV, 9.5kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV, 12.5kV, 13kV, 13.5kV, 14kV, 14.5kV, 15kV● AC/DC voltmeter (600V).● PI (Polarization Index) indication.● DAR (Dielectric Absorption ratio) indication.● Auto-ranging on all insulation ranges.● Backlight function.● Menu driven.● Visual and audible warning if external voltage is present. (≥30Vac or ≥30Vdc)● Auto-hold function to freeze the reading.● Overload protection.● Adjustment for testing time (duration) : 1~30 minutes● Auto-off.● Calendar.● Optical USB to RS-232 data transmission.● 200 measurement results can be saved in the memory and recalled on the display.● Safety standard : EN 61010-1 CAT IV 600V EN 61010-2-030 EN 61326-1

  • Digital H.V. Insulation Tester(12kV)

    7012 IN - Standard Electric Works Co., Ltd

    ● Protection class: IP66 (Lid closed)● Test insulation resistance up to 20TΩ (20000GΩ).● Short-circuit current up to 5mA● Microprocessor controlled.● 24 insulation test voltages :   500V, 1kV, 1.5kV, 2kV, 2.5kV, 3kV,   3.5kV, 4kV, 4.5kV, 5kV, 5.5kV, 6kV,   6.5kV, 7kV, 7.5kV, 8kV, 8.5kV, 9kV,   9.5kV, 10kV, 10.5kV, 11kV, 11.5kV, 12kV ● AC/DC voltmeter (600V).● PI (Polarization Index) indication.● DAR (Dielectric Absorption ratio) indication.● Auto-ranging on all insulation ranges.● Backlight function.● Menu driven.● Visual and audible warning if external voltage is present. (≥30Vac or ≥30Vdc)● Auto-hold function to freeze the reading.● Overload protection.● Adjustment for testing time (duration) :  ● 1~30 minutes● Auto-off.● Calendar.● Optical USB to RS-232 data transmission.● 200 measurement results can be saved in the memory and recalled on the display.● Safety standard : EN 61010-1   CAT IV 600V   EN 61010-2-030    EN 61326-1

  • 1-/3-Phase 1000A True RMS AC Power Clamp Meter

    Extech PQ2071 - Extech Instruments Corporation

    The PQ2071 is a 1-/3-Phase 1000 Amp True RMS AC Power Clamp Meter. Extech's multifunctional PQ2071 Power Clamp meter operates as a True RMS Clamp Meter, Power Meter, Multimeter, and AC Voltage Detector. Featuring a CAT IV-600 Volt safety rating, the PQ2071 measures AC Current, Voltage, Frequency and Power including True Power, Apparent Power, Reactive Power and Active Power. Measures 1-Phase and balanced 3-Phase True Power (kW), Apparent Power (kVA), Reactive Power (kVAR) and Active Power (kWh), plus Power Factor and Phase Angle. Featuring a 2.16 in. (55 mm) clamp jaw opening. Large dual backlit LCD display (9999 count) with bargraph. Frequency measurements to 200Hz. manually store/recall up to 99 data sets. Data Hold, Max/Min, and Auto power off functions. USB interface for connection to a PC for data logging function with included software. Complete with test leads, four color-coded leads and alligator clips, USB cable, PC software, 9V battery and soft case.

  • 20MHz 2-Channel Digital Oscilloscope

    Extech MS420 - Extech Instruments Corporation

    Extech's MS420 20 MHz 2-Channel Digital Oscilloscope offers a range of capabilities for effective troubleshooting of electronics and electronically controlled electrical systems. With 20 MHz bandwidth and conveniences like auto-set which optimizes the position, range, time base, and triggering to assure a stable display of virtually any waveform, the MS420 can be used in field repairs or bench duty. To identify subtle problems, Peak Detect features a fast 50 ns glitch capture. Core functions like XY Mode, FFT function, Trigger Hold off, Waveform Math, Averaging Mode and Persistence Mode all ensure you can confidently troubleshoot problems using a variety of approaches. To start up recurring testing routines, you can store and recall up to 4 waveform screens and setups to save time from job to job. This CAT II-rated oscilloscope extends its functionality with complete DMM functions that are displayed on the large 3. 8" (97mm) color LCD display. The MS420 comes with two 1X/10X oscilloscope probes, test leads, Windows XP/Vista compatible USB software and cable, capacitor measuring module, adjustment screwdriver, AC adaptor/charger, hard carrying case, user manual, and manufacturer's one-year limited warranty.

  • Coil Analyzers & Power Supplies

    IBEKO Power AB

    Coil analyzers and power supply units are portable and lightweight devices intended for use in harsh switchyard and industrial environments. The typical application is switchgear and circuit breaker testing when substation battery is not connected or available. An advantage over substation battery is enabled testing in under-voltage and over-voltage conditions. Furthermore, the stable voltage outputs with a very low ripple (<0,5%) enable an analysis of the coil and motor current graphs recorded with circuit breaker analyzers from different vendors.SAT40AD, POB30AD, and POB40AD are unique devices in the market due to their dual purpose:Power supply for coils and spring-charging motorsTesting circuit breaker’s coils, motor, and auxiliary circuitAll DV Power coil analyzers and power supply units have four separate outputs for opening and closing coils.SAT40AD has two powerful motor outputs (AC and DC) which can withstand up to 40 A inrush current.POB30AD and POB40AD have DC motor output rated up to 30 A and 40 A respectively. With the use of motor outputs, POB and SAT can also be used as a power source or a temporary battery charger.SAT40A II series instruments can be controlled via PC. The DV-Win application software is used to control both SAT and CAT (Circuit Breaker Analyzers & Timers) devices at the same time, making a unique test system for switchgear and circuit breaker testing.