Showing results: 241 - 255 of 276 items found.
-
LANTEK III Series -
IDEAL NETWORKS
New permanent link adapter saves money. Send test data anywhere using IDEAL AnyWARE app. Certifies multimode and single-mode fibre (optional). Professional PDF reports with free software. Certifies twisted pair cabling to TIA/ISO standards. The LanTEK III is an easy to use cable certifier that meets existing TIA and ISO/IEC performance requirements for testing up to Cat 7A/1000MHz. FiberTEK III adapters are used with LanTEK III for fast and simple certification of high bandwidth single-mode and multimode fiber optic cabling including support for encircled flux testing.
-
36330 -
S & G Tool Aid Corp
Use to test electronic fuel injection signals, idle air control circuit and spark plug circuits. Quickly diagnose "no start" and engine miss conditions in the electrical fuel injection and spark plug circuits. Analyze rough running engines. Includes 8 Noid Lights (for checking GM PFI, FORD TBI, GEO TBI, BOSCH PFI, GM TBI, GM SCPI, BOSCH 2 and GM Multec 2; 2 IAC Test Lights (for straight and 90 applications); and Cat. No. 23900, In-line Ignition Spark Checker.
-
AL-34WB 10A -
Standard Electric Works Co., Ltd
● Wire length: 1m approx. Silicone insulated wire (700mm) with wire connected to straight input plugs (150mm PVC wire), and wire for clamp (150mm PVC wire).● Outside diameter of silicone insulated wire: 6.4mm Outside diameter of PVC wire: 4mm● Input plug color: Red•Green•Black•Blue ● Current rating: 10A● Voltage rating: 300V● Designed for Milliohm meter, Micro-ohm meter, Low resistance measurement with high current injection. ● Conductor size: 40mm maximum● Safety standard: IEC/EN 61010-031 CAT IV 300V
-
6221 EL -
Standard Electric Works Co., Ltd
● Microprocessor-controlled.● Indicates phase rotation.● Indicates phase presence.● Tests for disconnection sensitivity.● Indicates battery status.● Tests for disconnection time.● Measures voltage phase to earth.● Select one of 3 Phase to test ELCB.● Color-coded test leads.● Phase presence indication from as low as 100Vac.● Very low consumption.● Fused earth leakage tester.● ELCB works 50Vac to 330Vac 50Hz / 60Hz.● Led indication of Voltage on ELCB.● Phase rotation and presence does not require battery to indicate.● EN 61010-1 CAT III 550V. EN 61326-1
-
AL-34WB -
Standard Electric Works Co., Ltd
● Wire length: 1.2m approx. Silicone insulated wire (1000mm) with wire connected to straight input plugs (130mm PVC wire), and wire for clamp (100mm PVC wire). ● Outside diameter of silicone insulated wire: 5mm Outside diameter of PVC wire: 3.5mm● Input plug color: Red•Green•Black•Blue ● Current rating: 5A● Voltage rating: 300V● Designed for Milliohm meter, Micro-ohm meter, Low resistance measurement with high current injection. ● Conductor size: 40mm maximum● Safety standard: IEC/EN 61010-031 CAT IV 300V
-
BAUR TDR 510 -
BAUR Prüf- und Messtechnik GmbH
Handheld Time Domain Reflectometer TDR 510. The BAUR handheld time domain reflectometer TDR 510 is used for fault location in all metal cables such as power cables, coaxial cables, data cables and communication cables. The BAUR TDR 510 comes with a device storage for 50 measurements and the option to compare the trace of an active TDR measurement with a stored trace.* Configurable for various measurement ranges and cable types* Standard-compliant, safe measurements on live cables through the measurement category CAT IV / 600 V* Ideal for fault location in the area of telecommunication, video technology, data and security technology
-
Extech EX503 -
Extech Instruments Corporation
The EX503 offers an array of must-have multimeter measurements including capacitance, frequency (dual sensitivity for electrical and electronic applications), diode test and continuity. Other features include Data Hold and Relative Hold, and manual- or auto-ranging modes. The latter automatically adjusts the measurement range based on the detected source such as electrical components and electronic equipment. The meter features 0.5 percent accuracy and a CAT IV-600-volt safety rating, protecting users even on outdoor wiring. Includes EX503 heavy-duty digital multimeter, double-molded test leads, magnetic hanging strap, 9-volt battery, carrying case, and user manual.
-
Extech EX411A -
Extech Instruments Corporation
The EX411A offers multiple functions so you can carry one meter into the field instead of several. The manual-ranging EX411A measures AC/DC voltage, AC/DC current, resistance, diode, and continuity, all with +/-0.5 percent basic accuracy. The unit has low current capability, measuring down to 0.1uA, and features input fuse protection and mis-connection warnings. A Type K thermometer is built in for surface or air temperature measurements. Comes with CAT III test leads, stand, hanging strap, holster with built-in test lead storage, Type K bead wire temperature probe, and battery.
-
885 PR -
Standard Electric Works Co., Ltd
● 3 functions in one unit: Phase Rotation, Phase Presence, Voltmeter● LCD contact type Phase Rotation Tester● Large LCD to show phase rotation and phase presence● Check a wide range of three phase power sources● Voltage range for phase rotation test: 75~600V AC ● Frequency range: 40~400Hz● 6000-count voltmeter● Auto ranging Voltmeter AC/DC● Data hold function● Auto power off● Convenient stand for viewing● Easy to use● Comply with EN 61010-1 CAT III 600V EN 61010-2-033 EN 61326-1
-
8010 IN -
Standard Electric Works Co., Ltd
● Microprocessor controlled.● Four insulation test voltages (DC) : 125V, 250V, 500V, 1000V● The maximum insulation measurement range is 200G ohm @1000V.● 1mA test current on insulation test at nominal voltage.● With a hand strap for easier holding.● Large LCD (78 × 67mm)● Auto-ranging.● Bar-graph indication.● Backlight function.● REL(Auto-null) function.● Auto AC/DC voltmeter.● Capacitor test.● Auto-test stop & smart hold.● Supplied with high quality test leads.● Safety standard : EN 61010-1 CAT III 600V IEC 61557-1 IEC 61557-2 EN 61326-1
-
ET4500 -
Martindale Electric Co. Ltd
The new ET4500 tester carries out all the tests needed to verify the safety of electrical installations in domestic, commercial and industrial wiring installations in accordance with the latest regulations.
can be used to carry out 3 wire earth testing and has on board memory to store and download all installation test results for documentation.
Everything about the new ET Series has been designed to save time and make testing easier.Fast, reliable high current and non-trip loop testing comes as standard together with a high level of input protection and a CAT IV safety rating .Supplied with a full range of accessories.
-
DSX CableAnalyzer™ Series -
Fluke Networks
The DSX CableAnalyzer Series copper test solution enables testing and certification of twisted pair cabling for up to 40 Gigabit Ethernet deployments and will handle any cabling system whether it is a Cat 5e, 6, 6A, 8 or Class FA and I/II. Certifying a cable is one part of a process that starts with system design and ends with system acceptance. The faster that process goes, the more profitable you'll be. Unfortunately, there are a lot of things that slow the process down setting up the tester incorrectly, testing to the wrong limits, waiting for skilled technicians to analyze and troubleshoot failures, misinterpretation of results, and producing test reports that customers cannot understand.
-
T-BERD/MTS-5882 -
Viavi Solutions Inc.
The T-BERD/MTS-5882 is extremely versatile, enabling the cell site technician to address all key tests with one, lightweight, handheld tester; including: Fiber Inspection: Dirty fiber connections are the #1 cause of network downtime. Microwave back-haul: The majority of microwave backhaul links around the world are still microwave. Enhanced Cable Diagnostics: Environmental factors can damage the CAT X shielded twisted pair cable connecting the microwave antenna. Fronthaul: Avoid dangerous tower climbs with CPRI testing including BERT, PIM detection, MIMO diversity, RET, and VSWR. Backhaul: In addition to packet testing across error-prone microwave hops.
-
LDH400 Series -
Aim-TTi
Versatile solution for direct testing of dc power sources and PFCsConstant current, resistance, conductance and power modesWide voltage and current range, 10 to 500V and 0 to 16A400 watts continuous dissipation at 28°C (360W at 40°C)High resolution and accuracy for level settingBuilt-in transient generator with variable slewCurrent monitor output for waveform viewingVariable drop-out voltage for battery testingHigh resolution backlit graphic LCD with soft key controlAnalogue remote control of levels and TTL control of on/off and transient switchingFront and rear input terminalsLoad inputs rated to CAT II (300V)Full bus control via USB, RS232 and LXI compliant LAN interfacesGPIB Option
-
Extech 380976-K -
Extech Instruments Corporation
The 380976-K is a Single Phase/3 Phase 1,000 Amp AC Power Clamp Meter Kit. Measures 1/3-Phase True Power (kW), Apparent Power (kVA), Reactive Power (kVAR), Horsepower (HP), Power Factor, and Phase Angle with Lead/Lag indicator. Auto Detect AC/DC Voltage measurements with simultaneous frequency display. In addition, the supplied test lead kit includes two CAT IV 72" test leads, 2 modular test probe handles, 2 plunger activated jaw clips, and 2 extra-large alligator clips. Complete with test lead kit, Type K probe, carrying case and 9V battery.