Filter Results By:

Products

Applications

Manufacturers

Amplitude

Amplitude Intensity Modulation

See Also: Interference


Showing results: 211 - 225 of 343 items found.

  • Large Photo Signal Generator

    DDS9m - Novatech Instruments , Inc.

    170MHz 4-Channel Signal Generator. The DDS9m generates four independent, phase synchronous sine wave output signals and is programmable in 0.1Hz steps from 0.1Hz to 171MHz. Programming is via an RS232 serial interface. Phase is 14-bit programmable and amplitude is 10-bit programmable. The DDS9m is accurate to 1.5ppm when using the on board TCXO timebase or you can use an external timebase. It requires 3.3 VDC power. SOF8_409 windows software is available as an extra cost accessory.

  • Hardy Shaker

    HI-913 - Metrix

    This Hardy Shaker provides the ability to set the amplitude and change the frequency range without the amplitude changing. This automation makes conducting a test easier. A test can be conducted on a vibration transducer and manually recorded. Multiple tests are not saved; for multiple tests use the HI-903 or HI-803 units. The HI-913 is used for testing from 7 to 10,000 Hz, it offers adjustable frequency and vibration levels. This provides a reference source for verifying the accuracy of vibration transducers, connectors, cabling and instruments or instrumentation systems. The HI-913 has a ruggedized suspension system that can support heavy transducers (up to 800 grams - see frequency limits in the manual). The HI-913 has a built-in battery charger that can operate on 120 or 240 VAC. The unit comes in a rugged Pelican case.

  • Digital Signal Generator

    MCH Instruments Co.,Ltd.

    Digital Signal Generator*signal frequency:0.1Hz~2MHz, continuously variableave from: square, sine*output attenuator: 0dB,, 20dB, 40dB, 60dB*output level: 20Vp-p in open circuit, not less than 10Vp-p with 50Ω load*rising and falling edge of square not more than 35ns,*sine distortion less than 1%, amplitude –frequency characteristic : ±0.5dB within 100KHz, ±1dB above 1MHz*frequency meter: 10Hz~30MHz*power supply : AC 220V(110V optional)

  • Handheld Gauge for Nondestructive Coating Thickness Measurement

    PHASCOPE PMP10 DUPLEX - Helmut Fischer AG

    Handheld gauge for rapid and precise measurement of duplex-coatings (for the simultaneous measurement of lacquer and zinc or of lacquer/Al)Probe ESG20 uses measuring principles according DIN EN ISO 21968 (phase sensitive eddy current); DIN EN ISO 2178 (magnetic induction); DIN EN ISO 2360 (amplitude eddy current).Delivery with PC software FISCHER DataCenter with the following functionality: Transferring and archiving measurement data, comprehensive statistical and graphical evaluations, easy creation and printing of inspection reports

  • High Impedance Differential Clock Divider

    Alliance Support Partners, Inc.

    he ASP-DCD-00 board is a high impedance input clock divider circuit. It is designed to provide minimum load to a clock source for frequency measurement. It accept single ended (Unbalanced) or differential (Balanced) signals with amplitudes as little as 100mV rms; it divides the input signal frequency from 2 to 256 times depending on shunt jumper selections on J3. The board requires 5VDC 500mA power source to operate. The output is capable of driving 5V TTL logic levels.

  • Multiple Signal Generator

    ETEK TECHNOLOGY CO., LTD

    1. Two Signal Output Ports2. Frequency Range:10 Hz ~ 100 kHz and 1 kHz ~ 15 MHz3. Output Waveforms:Sine, Triangle, Square,TTL Pulse, AM, FM4. Amplitude:10 Vpp(Max)5. Built-in LCD CountersDC Power Supply:1. Triple Outputs (One Variable, two Fixed Output)2. Constant Voltage Operation3. Low Ripple and Noise4. Built-in 3-Digit Voltage Indicator5. Overload Protect6. Overload Buzzer Indicator

  • Near-Field Detection Module for Imaging

    Transmission - Neaspec GmbH

    Detection optimized for high performance near-field imaging in transmission-modeEnables optical amplitude and phase resolved near field measurementsPatented background-free detection technologyEnables bottom-side (transmission-mode) sample illumination with broadband mirrorSuited for visible and infrared wavelength range 0.5 20 mRequires transparent sample substrateMotorized parabolic mirror for easy beam-alignment in transmission-modeStationary focal point with respect to AFM-tipVariable illumination spot size (ca. 2m 100m)Suitable for plane-wave illuminationSupported AFM scan-speed: up to 20 m/s @ highest spatial resolution

  • Single Channel Analyzers

    ORTEC

    A single channel analyzer (SCA) produces an output logic pulse on the condition that the peak amplitude of its input signal falls within the pulse-height window that is established with two preset threshold levels. ORTEC provides two basic types or classifications of SCAs: non-timing SCAs and timing SCAs. Non-timing SCAs produce an output pulse if the input signal is within the window settings. Timing SCAs produce an output logic signal precisely related in time to the occurrence of the event being measured.

  • Time Code Reshaper/ Distributor

    SR-28 - Brainstorm Electronics Inc.

    The SR-28 can drive time code over long cables, making it ideal for synchronization during live shows and remote recording. The SR-28 time code distributor, with two inputs and eight outputs, reshapes time code while distributing it, eliminating amplitude distortions and level fluctuations. The level of each output is individually adjustable via front panel pots. The input is selected via a front panel switch. Also included are 2 power inputs and an automatic switch over in case of failure.

  • Adaptive Relay, Virtex-6 FPGA - XMC

    Model 71624 - Pentek, Inc.

    - Modifies 34 IF signals between input and output- Up to 80 MHz IF bandwidth- Two 200 MHz 16-bit A/Ds- Two 800 MHz 16-bit D/As- 34 DDCs and 34 DUCs (digital downconverters and digital upconverters)- Signal drop/add/replace- Frequency shifting and hopping- Amplitude boost and attenutation- PCI Express Gen 1: x4 or x8- RoHS Compliant Lead-Free Version Available- Synchronize up to eight modules with Model 7893 System Synchronization and Distribution Amplifier - PCIe

  • 16 Channel Multievent QDC

    V792N - CAEN S.p.A.

    The Model V792N is a 1-unit wide VME 6U module housing 16 Charge-to-Digital Conversion channels with current integrating negative inputs (50 Ohm impedance). For each channel, the input charge is converted to a voltage level by a QAC (Charge to Amplitude Conversion) section. Input range is 0 ÷ 400 pC. The Model V792N features LEMO 00 connectors for both input and control signals. The outputs of the QAC sections are multiplexed and subsequently converted by two fast 12-bit ADCs.

  • Circuit Breaker Testing

    Weshine Electric Manufacturing Co., Ltd

    Time measurement: 12 fracture intrinsic points, closing time, with the same period, phase with the same period.2. Reclosing measurement: each fracture closing - minute, minute - closing, minute - closing - minute process time, one minute time,one closing time, two closing time, gold short time, no current value.3. Bounce measurement: closing bounce time, bounce times, bounce waveform of each fracture, rebound amplitude of each fracture.

  • Circuit Breaker Analysis System

    Weshine Electric Manufacturing Co., Ltd

    1. Time measurement: 12 fracture intrinsic points, closing time, with the same period, phase with the same period.2. Reclosing measurement: each fracture closing - minute, minute - closing, minute - closing - minute process time, one minute time,one closing time, two closing time, gold short time, no current value.3. Bounce measurement: closing bounce time, bounce times, bounce waveform of each fracture, rebound amplitude of each fracture.

  • Dual Channel Driver Card

    42460 - Pulse Instruments

    Two channels of 32 MHz clock drivers with up to 20 volt amplitude. The output voltage range is ±20 V, with independent high and low voltage settings. The inputs to the Card can be optically isolated. The card also contains voltage and current sense capability, which allows muxing of the current or voltage output measurements from all the Driver Channels in the system to a single DVM. The card allows independent programming of the rise and fall time of each channel one nanosecond increments.

  • Dual Channel Driver Card

    40461 - Pulse Instruments

    Two channels of 8 to 10 MHz drivers (25 V amplitude). The output voltage range is ±25V, with independent high and low voltage settings. The inputs to the Card are optically isolated. The card also contains voltage and current sense capability, which allows muxing of the current or voltage output measurements from all the Driver Channels in the system to a single DVM. The card allows independent programming of the rise and fall time of each channel as low as one nanosecond increments.

Get Help