Filter Results By:

Products

Applications

Manufacturers

Amplitude

Amplitude Intensity Modulation

See Also: Interference


Showing results: 271 - 285 of 344 items found.

  • Transition Time Converter, 500ps

    15433B - Keysight Technologies

    The new design of these transition time converters ensures very low signal reflection far beyond the 3 dB point, unlike conventional converters. Reducing the signal transition-times also increases the overall pulse-performance for overshoot/reflection sensitive applications. The converters are fitted with SMA connectors, one male, one female. These converters have been designed to convert the fixed transition-times of the Keysight 8133A 3 GHz timing generator (<100 ps transitions) to slower, fixed transition-times (150 ps, 250 ps, 500 ps, 1 ns, 2 ns) hence reducing the signal bandwidth. All transition-times are from 10% to 90% of amplitude.

  • Transition Time Converter, 250ps

    15432B - Keysight Technologies

    The new design of these transition time converters ensures very low signal reflection far beyond the 3 dB point, unlike conventional converters. Reducing the signal transition-times also increases the overall pulse-performance for overshoot/reflection sensitive applications. The converters are fitted with SMA connectors, one male, one female. These converters have been designed to convert the fixed transition-times of the Keysight 8133A 3 GHz timing generator (<100 ps transitions) to slower, fixed transition-times (150 ps, 250 ps, 500 ps, 1 ns, 2 ns) hence reducing the signal bandwidth. All transition-times are from 10% to 90% of amplitude.

  • Digital AC milli Volt meter

    PGP Electronics Private Limited

    PGP Electronics Digital AC Mill voltmeter is a very versatile and general purpose equipment for the measurement of audio frequencies. It is useful in measuring low amplitude signals over a wide band of frequencies with precision. Its has a wide band width and sensitivity is 10uV. This instrument is useful for all amplifiers/ audio system manufacturers, college laboratories to measure input/output of any amplifier as well as frequency response of that amplifiers. .

  • Standard CW Amplifiers

    Tomco Technologies

    The BT-AlphaA-CW series is a range of classAB RF power amplifiers covering the 10kHz to1MHz frequency range.• Rugged, solid-state design - high reliability• Extremely high phase and amplitude stability• High linearity• In-Built Protection• Very fast blanking• Capable of pulsed operation• Competitively pricedSuitable for CW radar, communications, HF/VHF jamming, particle accelerator applications/plasma systems, plasma, RF heating and otherscientific applications.

  • 17 To 19 GHz QPSK Modulator

    CCM19001 - Teledyne RF & Microwave

    The CCM19001 is a Differential Drive Digital QPSK (Quadrature Phase Shift Keying) modulator operating across the 17.0 to 19.0 GHz frequency range. The modulator utilizes differential drive digital inputs (180º apart) to drive both of the bi-phase modulators (mixers) integrated into the assembly. The modulator is a combination of a matched pair bi-phase modulators, which are in quadrature (90º) to each other. It is modulated by switching polarities of the DC voltage controls in 4 different logic states ("0,0", "0,1", "1,0" & "1,1") for 4 phase states. The QPSK modulator provides constant amplitude, 90º vector: 0 (ref.), 90º, 180º, 270º and operates across the -55º to 85º C temperature range.

  • Lightning Current Generator

    Shanghai Guantu Technology Co., Ltd.

    The lightning wave impulse current generator is an impulse current generator that generates a simulated lightning current waveform . Its working process is as follows: first, the transformer charges the capacitor bank through the silicon pile, when the charging voltage reaches a predetermined value, the spark gap is triggered, and the capacitor is discharged through the total inductance and total resistance of the circuit. When the resistance is greater than or equal to the critical damping value, a unidirectional impulse current wave is generated in the circuit. When the resistance is less than the critical damping value, an oscillating impulse current wave is generated. The magnitude of the impact current amplitude is related to the circuit parameters. When the capacitance value and charging voltage are the same, the smaller the inductance value, the greater the current amplitude. In order to obtain as much current as possible, a pulse capacitor with a small inductance value is usually selected, and the total length of the connecting line should be as short as possible when arranging the main capacitor, so that the total loop inductance value can be reduced as much as possible.

  • Accessory for Test Chest 3G Facilitating 'EYE' Analysis

    EYE~POD - Murraypro Electronics

    Designed to interface with Murraypro's Test Chest 3G, the EYE~POD accessory module extends monitoring capability to include SDI envelope parameters from SD through to 3G. Users receive immediate visual indication of the quality of an SDI input signal with regard to both overall signal amplitude and Jitter. Drawing power from TC3G, the coupled-combo may be used on local battery power, or supported with an external mains PSU

  • AC Hysteresis Graph Test System

    DX-2012M - Dexing Magnet Tech. Co., Ltd

    Automatic measurement of the dynamic magnetic hysteresis loop of oriented and non-oriented silicon steel under the condition of 50 Hz, 60 Hz, 400 Hz and 1 kHz, accurate measurement of the static magnetic characteristic parameters such as amplitude permeability μa, loss angle δ, specific total loss Ps, remanence Br and coercivity Hc. With special testing fixture, it can directly measure the iron core and stator core of the transformer.

  • PXIe Vector Signal Generator: 1 MHz to 3 GHz or 6 GHz

    M9381A - Keysight Technologies

    Choose your RF modulation bandwidth, 40, 100, or 160 MHz, and easily upgrade as test needs change Increase throughput with fastest RF frequency tuning and amplitude switching for high-speed automated test Save space with a compact solution for up to 8x8 MIMO with phase coherence Get up and running quickly with validated application-specific reference solutions Simplify signal creation with Keysight's Signal Studio and Waveform Creator

  • Handheld Digital Spectrum Analyzer

    915M - Seeed Technology Inc.

    Frequency band: 910-920 MHz (enhanced to 900-930 MHz if an Expansion Module is connected)Frequency span: 112 KHz-10 MHz(enhanced to 30 MHz if an Expansion Module is connected)Graphics LCD 128x64 pixels, great visibility outdoorsPC Windows client supports Windows XP/Vista/Win7 both 32 and 64bitsBacklight for great indoor visibilityStandard SMA 50 ohms connector, a matching antenna is includedAmplitude resolution: 0.5dBmDynamic range: -115dBm to 0dBmAbsolute Max input power: +5dBmAverage noise level (typical): -110dBmRF Generator amplitude: 0dBm to 20dBmFrequency stability and accuracy (typical): +-10ppmAmplitude stability and accuracy (typical): +-3dBmFrequency resolution: 1KhzResolution bandwidth (RBW): automatic 2.6Khz to 80KhzWeight: 185gSize: 113x70x25 mm

  • Measurement

    Vibration Meter - ZETLAB Company

    The input signal of the Vibration meter software, which is the output signal of the accelerometer, i.e. the vibrational acceleration signal, is filtered by means of one of four possible digital band filters. Then, based on this signal, vibrational velocity and displacement signals are calculated by means of integrating filters. Thus, the software generates three signals which are transferred to the ZETLAB data server virtual channels created by the program and having the word “Acceleration”, “Speed” or “Displacement” in their names, respectively.Signals are averaged for a selected time interval (0.1 s, 1 s, or 10 s), after which the obtained values are displayed in the dialog box elements of the Vibration meter program. It is possible to display a root-mean-square (RMS), average amplitude or peak value.

  • 4-Way Power Splitter/Combiner

    ZN4PD1-183W+ - Mini-Circuits

    Mini-Circuits’ ZN4PD1-183W+ is a 4-way 0˚ splitter/combiner covering a wide range of applications from 4000 to 18000 MHz including test and measurement, EW, SatCom and more. This model is capable of handling up to 30W RF input power as a splitter and passing up to 4A DC current from the sum port to alloutput ports (100mA each port). Its outstanding combination of high power and low loss minimize intrinsic losses and provide excellent signal fidelity from input to output. It also provides high port-to-port isolation, excellent VSWR and low amplitude and phase unbalance. It comes housed in a rugged aluminum alloy case with SMA connectors at all ports.

  • PXI Attenuator Modules

    Pickering Interfaces Ltd.

    Programmable RF Attenuators – accurate DC to 3GHz programmable attenuator has a 1dB step resolution, allowing it to adjust signal amplitudes for optimum measurement by other devices.Solid State Programmable RF Attenuators – available in triple or hex formats with bandwidths between 10MHz and 6GHz.High Voltage Attenuators – provide a convenient way of attenuating high voltage low frequency signals to levels that can be captured by other PXI devices without risk of damaging them.

  • Handheld Digital Spectrum Analyzer,

    Seeed Technology Inc.

    Frequency band: 240 - 960 MHz and 2.35 – 2.55 GHzFrequency span: 112KHz - 100MHzGraphics LCD 128x64 pixels, great visibility outdoorsPC Windows client supports Windows XP/Vista/Win7 both 32 and 64bitsBacklight for great indoor visibility2 standard SMA 50 ohms connector, one for Sub-GHz wideband Nagoya NA-773 telescopic antenna included and another one for 2.4GHz band with helical antenna included.Amplitude resolution: 0.5dBmDynamic range: -115dBm to 0dBmAbsolute Max input power: +5dBmAverage noise level (typical): -110dBm2.4GHz RF Generator amplitude: -30dBm to +1dBmFrequency stability and accuracy (typical): +-10ppmAmplitude stability and accuracy (typical): +-3dBmFrequency resolution: 1KhzResolution bandwidth (RBW): automatic 2.6Khz to 600KhzWeight: 185gSize: 113x70x25 mm

  • ARINC 429 XMC Interface Module

    XMC-429 - Avionics Interface Technologies

    16, 32, or 64 ARINC 429 channels (up to 32 Tx & 32 Rx) - Programmable Tx channel output amplitude - Programmable high/low speed operation - Eight (8) Discrete I/O (Four (4) inputs, and four (4) outputs) - Concurrent operation of all Tx/Rx Channels at high data rates - Full error injection and detection - Data capture filtering, 100% bus recording, and physical bus replay - IRIG‐B time code encoder/decoder for data correlation - Conduction-cooling and/or conformal coating available - Designed for extended temperature operations - ANSI Application interfaces supporting C, C++, C#, and .net development - Device driver support: Windows, Linux, and VxWorks (others provided upon request)

Get Help