Showing results: 1111 - 1125 of 1523 items found.
-
Model T102 -
Teledyne Advanced Pollution Instrumentation
The Model T102 TRS analyzer uses the proven UV fluorescence principle to measure Total Reduced Sulfur at levels commonly required for ambient air monitoring.The Model T102 uses a high temperature external converter set at 850°C to allow conversion of H2S, methyl mercaptan, dimethyldisulfide, and methyl-disulfide to SO2 at this temperature with efficiency greater than 98%. A switching option alternately measures TRS and SO2 while showing both readings concurrently on the front display.
-
MRC ltd.
* Absolute vacuum & absolutepressure measurement.* Wide measure range from 1 to1500 mbar.* Overload protection up to 2000mbar max.* 8 kind display units :torr, mm Hg, micron, mbar, KPa,Pa, inch Hg, psi* Separate probe, easy operation.* Heavy duty sensor used for air, oilgas, liquid.* Auto shut off saves battery life.* Microprocessor circuit.* Maximum & minimum records.* Data Hold function.
-
VERTEX 80/80v -
Bruker Optics
The VERTEX 80 and the VERTEX 80v vacuum FT-IR spectrometers are based on the actively aligned UltraScan™ interferometer, which provides PEAK spectral resolution. The precise linear air bearing scanner and PEAK quality optics guarantees the ultimate sensitivity and stability. The VERTEX 80v is an evacuated optics bench that can eliminate atmospheric moisture absorptions for ultimate sensitivity and stability; enabling demanding experiments such as high resolution, ultra fast rapidscan, step-scan, or UV spectral range measurements.
-
CM-51 -
Taylor Dynamometer, Inc.
AC power, air and water required at one side wallas applicable.• Room length, and pit location within length,must be determined by user to fit maximumtruck length and rear overhang.• Provide at least one man door for fire escapenear rear of room, but not in rear wall becausesomeone entering during a test could be struckby a stone flung from a tire. Provide ample fireextinguishers at each door and near driver.• “Back-on, Drive-off” installation configurationpreferred.
-
TD-24 -
Taylor Dynamometer, Inc.
AC power, air and water required at one side wallas applicable.• Room length, and pit location within length,must be determined by user to fit maximumtruck length and rear overhang.• Provide at least one man door for fire escapenear rear of room, but not in rear wall becausesomeone entering during a test could be struckby a stone flung from a tire. Provide ample fireextinguishers at each door and near driver.• “Back-on, Drive-off” installation configurationpreferred
-
CM-51S -
Taylor Dynamometer, Inc.
AC power, air and water required at one side wallas applicable.• Room length, and pit location within length,must be determined by user to fit maximumtruck length and rear overhang.• Provide at least one man door for fire escapenear rear of room, but not in rear wall becausesomeone entering during a test could be struckby a stone flung from a tire. Provide ample fireextinguishers at each door and near driver.• “Back-on, Drive-off” installation configurationpreferred.
-
CR8000 -
Manncorp
A combination of 8 independently controlled full-convection heating zones (16), 2 cooling zones, and low-velocity, low turbulence air flow allows the CR8000 reflow oven to provide you with thermal accuracy of ±1°C and a ΔT of ±2°C across PCB assemblies to 22" (570 mm) wide. This high-performance model takes up less floorspace than comparable alternatives on the market and offers a throughput that can keep pace with even high-volume production requirements.
-
FST-AM -
Foresight Electronics Co., Ltd.
A data logger, is an electronic instrument that records measurements at set intervals over a period of time. Depending on the particular data logger, measurements can include: air temperature, relative humidity, AC/DC current and voltage, differential pressure, time-of-use (lights, motors, etc.), light intensity, water temperature, water level, dissolved oxygen, soil moisture, rainfall, wind speed and direction, leaf wetness, pulse signals, room occupancy, plug load, and many more.
-
Desco Industries, Inc.
Point-Of-Use Ionizer, Adjustable (30-100 PSI) Compressed Air IonizerNeutralize Electrostatic Attraction (ESA) to control contamination by dislodging dust and debris attracted by static electricity.Detachable 7'' long ESD Protective Flexible Hose with Thumb Button Designed to for a wide range of motion and simple operation.Adjustable Balance (20 Volts) with Less Than 1 Second Discharge Time At 6 InchMeets required limits ANSI/ESD S20.20 tested per ANSI/ESDSTM3.1 and ESD TR53
-
DUSTTRAK DRX-8533 -
TSI Inc.
Real-time dust monitoring takes a giant leap forward! Only the DUSTTRAK™ DRX Aerosol Monitor 8533 can simultaneously measure both mass and size fraction - no other monitor can do both. The DUSTTRAK DRX desktop monitor is a battery operated, data-logging, light-scattering laser photometers that gives you real-time aerosol mass readings. It uses a sheath air system that isolates the aerosol in the optics chamber to keep the optics clean for improved reliability and low maintenance.
-
DUSTTRAK DRX-8534 -
TSI Inc.
Real-time dust monitoring takes a giant leap forward! Only the DUSTTRAK™ DRX Aerosol Monitor 8534 can simultaneously measure both mass and size fraction - no other monitor can do both. The DUSTTRAK DRX handheld monitor is a battery operated, data-logging, light-scattering laser photometers that gives you real-time aerosol mass readings. It uses a sheath air system that isolates the aerosol in the optics chamber to keep the optics clean for improved reliability and low maintenance.
-
YAV90PNE -
6TL Engineering
The YAV90PNE is a complete “plug & play” pneumatics subsystem controlled by CAN, for ATEs with Virginia Panel receiver. Thanks to this module, pneumatics actuators that are commonly used in the fixture side of an ATE, can be controlled. 10 3-way micro-valves are able to contorl 10 simple effect actuators or else 5 double effect ones. The module includes input for the position sensors. A pressure sensor is also included, so that the system air mains working pressure can be set between a minimum and a maximum.
-
SONOSCAN CFC / CF -
SONOTEC GmbH
Due to the strong damping properties of air, low frequencies in the kHz range are used in air-coupled ultrasonic testing. It is therefore all the more important that the ultrasonic transducers offer a particularly high sensitivity in order to ensure high penetration and improved resolution. We achieve this, among other things, by installing preamplifiers in the receiver probe as well as by using our own Piezocomposite Technology, which enables a flexible use of the matching materials in our CFC and CF probes.
-
Laminar -
ATEQ Corp.
If you need high-quality air flow testers, you’ve come to the right place. We carry equipment for mass flow and leak testing, laminar flow, and continuous flow. You have the option of choosing touch screen or standard digital. All our equipment is compact and includes high-performing, state-of-the-art technology. Begin testing your equipment with our premium-grade flow testing equipment. Explore our amazing selection of flow testing equipment.
-
KNM X series -
KAPP NILES Metrology GmbH
machine structure with outstanding intrinsic accuracylarge bearing distances of guidesinherently stable granite machine base on active dampers to absorb vibrations ? no foundation requireddrive system close to center of gravitylinear motors in X-, Y-, Z- measuring axeshigh precision air- or hydrostatic bearing rotary tables (diameters from 500 to 1,800 mm) with direct drive and through holemotorized positioning of measuring column (V-axis) to the actual workpiece diameterlaser based system for safe operation