Line Replaceable Unit
unit of a complex engineered system, designed for quick replacement.
See Also: LRU
- Pickering Interfaces Inc.
product
PXI 22-Channel 2A Fault Insert Switches
40-202-001
This is the 22 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test.
-
product
AIS Air Data Test System
F-16
The primary function of the Air Data Test System (ADTS) is to perform testing and fault isolation of pneumatic-type Units Under Test (UUTs). To test a UUT, the operator connects the associated Line Replaceable Unit (LRU) Integrated Test Adapter (ITA) to the rackmount Avionics Intermediate Shop (AIS) test station. The operator connects the ADTS to the IAIS via an RS-232 Interface and then finally, connects the UUT to the ADTS using the supplied cables and hoses.
-
product
Avionics Suite Tester
Based on order from the Navy, Data Patterns developed the complete Automated Test Equipment required for validating all the Line Replaceable Units (LRUs) utilized in the Seaking Helicopter. The upgrade was carried out at multiple Naval bases in India.
-
product
Air Data Calibration Test System (ADCTS)
ADCTS-1000 Series
TestVonics Air Data Calibration Test System (ADCTS) is high precision advanced Secondary Air Data Controller-Monitor system. The ADCTS-1000 Series is a self-contained maneuverable rack mounted air data management system. The ADCTS is used in calibration labs, avionics engineering and avionics/instrument shops. The system is designed to perform both manual or automated test and calibration routines for a variety of air data test equipment (ie. test sets, air data computers, altimeters, airspeed indicators and line replaceable units). The ADCTS can be configured for use in both commercial and military environments.
-
product
S500 Test Solution
The S500 Bench Test Equipment (BTE) is customized to test the Line Replaceable Unit (LRU) to determine the faulty Lowest Level Replaceable Unit (LLRU). Once a faulty LLRU is discovered, a separate application program specifically designed for the LLRU is executed to further isolate the fault.
-
product
Air Data Computer (ADC) Tester
MS 1122
The ADC tester is used in 2nd line maintenance is to check the functionality of ADC. This unit is a rugged customized hardware based on full functionality test of ADC. The Air Data Computer (ADC) Tester is a fully automated GO/NOGO tester with full functional testing in 2nd line maintenance. This tester is to test ADC at unit level and identify faulty Shop Replaceable Unit (SRU). This tester is also used to carry out PI checks on ADC before clear them for installation on aircraft. ADC Interface ...show more -
product
Pulse AC Method Area Ionizers
ER-X Series
Panasonic Industrial Devices Sales Company of America
The ER-X Series Area Ionizers utilize the pulse AC ionization design to achieve high-speed charge removal of wide surface areas for high-volume production lines. In addition to supporting compressed air ionization, the ER-X also features both airless and low-pressure ionization modes for applications where tiny workpieces can be easily blown away. Additional features include automatic ion balance and discharge frequency control (manual control is also possible), flat discharge surface for easy...show more -
product
Depot Repair & Redesign
ARC has worked with the DoD/military agencies and the FAA to help service and repair critical products in the national air system and various line replaceable units (LRUs) that may contain multiple circuit cards. With a skilled team of engineers and service technicians that can troubleshoot, reverse engineer, and help in finding components for damaged and obsolete parts, ARC is the right depot partner.
-
product
GPU
The MAGIC1A is a rugged line replaceable unit (LRU) suitable for high-performance computing in the harshest of environments. The combination of Intel and NVIDIA processors in a low SWaP-C3 package ensure it can be used across a wide range of commercial and military applications, including displays, situational awareness, data/radar processing, video processing, classification, and artificial intelligence (AI).
-
product
Instrumentation Amplifiers
HIGH-POWER RADIO FREQUENCY (RF) AND MICROWAVE AMPLIFIERS, TWTA AND SOLID STATE
Communications & Power Industries
electromagnetic compatibility (EMC) high-intensity radiated field (HIRF) testing, military testing, electronic warfare simulation and scientific applications are based on the same switched-mode power supply technology as its rugged amplifiers. As a result, these instrumentation amplifiers have all the same performance and reliability advantages as the rugged product line, but have been neatly re-packaged into compact, lightweight and affordable rack-mountable units more suitable for less demandi...show more -
product
Intermittent Fault Detection & Isolation System
IFDIS
The IFDIS™ uses patented Intermittent Fault Detector technology that simultaneously and continuously monitors every circuit path within a Unit Under Test (UUT) - such as a Line Replaceable Unit (LRU) chassis' interconnects - for intermittent continuity failures that occur for as short as 50 nanoseconds. This state of the art technology is combined with an environmental chamber and vibration table, which simulate the UUT’s operational environment and cause intermittent faults to manifest, creating a system that is unsurpassed in intermittent fault detection.
-
product
100-Watt DC Power Line Conditioner w/Holdup
44LS1
NAI’s 44LS1 is a 100-Watt Power Line Conditioner with holdup time that protects downstream DC/DC converters from transients, low voltage conditions, and power interruptions. This unit accepts +28 VDC input and provides 22.5 to 30 VDC at 100 Watts to all downstream DC/DC converters.
-
product
500 Watt AC/DC Power Line Conditioner, 3U VPX, Holdup Time
VPX56-3HU
NAI's VPX56-3HU is a rugged, high-performance 500-Watt Output +28 VDC Input 3U VPX AC/DC Power Line Conditioner designed for aerospace, defense, and industrial markets. This off-the-shelf power supply plugs directly into a standard VPX conduction cooled chassis and protects downstream DC-DC converters from MIL-STD-704 transients, low-voltage conditions and power interruptions, providing up to 50 milliseconds of holdup time at up to 500-Watts. Continuous Background Built-In-Test (BIT) and I2C communication are included.
-
product
50 µs Pulse Medium Current Source/Measure Unit (MCSMU)
B1514A
The 50 s Pulse Medium Current SMU is an SMU designed for faster pulsed IV measurement. It enables a pulsed measurement down to 50 s pulse width, a 10 times or more narrow pulsed measurement than provided by a comparable conventional SMU. In addition, the instrument offers a wider range and versatility, up to 30 V / 1A, with voltage/current programmability. It is useful to characterize high to medium power devices on the new materials such as SiC and GaN, and organic devices, and the MCSMU expands your choices of pulsed IV measurement.
-
product
6x 3U OpenVPX MOSA Data Concentrator Unit
SIU36-DCUVARM-01
SIU36-DCUVARM-01 is a Modular Open Systems Approach (MOSA) DO-178C & DO-254 Certifiable Data Concentrator Unit (DCU) with low power high performance OpenVPX Xilinx UltraScale+ SBC with Quad Core ARM Cortex -A53, 8 GB DDR4 SDRAM, 32 GB SATA Flash, 2 x 10/100/1000Base-T Ethernet, USB 3.0, FIPS-140-3 Level 3 Cyber Security, and Single Event Upset support.
-
product
Source Measure Units (SMUs)
B1511B
The SMUs of B1500A integrate 4-quadrant voltage/current source and measurement capabilities for accurate IV measurement with the range of 0.1 fA - 1 A / 0.5 µV - 200 V. It supports spot, sweep, pulse sampling and QS-CV measurements.
-
product
Dual Bus 75-Channel 2A PCI Fault Insertion Switch
50-190-002
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
product
PXI 11-Channel 2A Fault Insert Switch
40-202-101
This is the 11 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test
-
product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
42-203-001
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
product
PXIe Short SMU
52403P
Chroma's 52403P is a PXI Express Short Pulse SMU (Source/Measure Unit) designed for fast, precise and reliable sourcing and measurement of thermo-sensitive devices such as high-power laser diodes (LD). Integrating a high-speed pulser, a high precision SMU and a DAQ module into a single PXIe SMU, the 52403P can measure both the LIV and the low-level leakage current of a high-power LDs.
-
product
PXIe-4141, 4-Channel, ±10 V, 100 mA, Precision PXI Source Measure Unit
781743-01
PXIe, 4-Channel, ±10 V, 100 mA, Precision PXI Source Measure Unit - The PXIe-4141 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4 wire) sensing for accurate measurements. The fast sample rate of the PXIe-4141 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can...show more -
product
3 Function Slot MOSA Nano Data Concentrator Unit (DCU)
NIU3A-DCU-01
NIU3A-RDC-01 is a Modular Open Systems Approach (MOSA) Data Concentrator with low power high performance ARM Cortex -A53 processing. 8 GB RAM, 32 GB SATA Flash, 2 x 10/100/1000Base-T Ethernet.
-
product
PXI Single Bus 32-Ch 2A Fault Insertion Switch
40-190B-201
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 8 Channel
40-201-008
This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external...show more -
product
4x 3U OpenVPX MOSA Actuator Interface Unit
SIU34-AIUVARM-01
SIU34-AIUVARM-01 is a Modular Open Systems Approach (MOSA) DO-178C & DO-254 Certifiable Actuator Interface Units (AIU) with low power high performance OpenVPX Xilinx UltraScale+ SBC with Quad Core ARM Cortex -A53, 8 GB DDR4 SDRAM, 32 GB SATA Flash, 2 x 10/100/1000Base-T Ethernet, USB 3.0, FIPS-140-3 Level 3 Cyber Security, and Single Event Upset support.
-
product
PXI Fault Insertion Switch, 6-Channel, Two Fault Buses, 30 A, Hardware Interlock
40-191B-012-HI
The 40-191B-012-HI is a PXI fault insertion switch with hardware interlock using solid state switching elements and is capable of carrying 40A on single channel or 30A on all channels at the same time and provides a robust solution to high current fault insertion.
-
product
PXI Source Measurement Unit
PX773x
The PX773x is a high precision, high speed source and measurement unit, which is designed for automated high throughput testing.
-
product
Source Measurement Unit
SMU8
The SMU8 offers high voltage SMU in a compact, 3U PXI / USB form factor. The SMU8 supports 0V to +4V 0.5A or 0V to +12V 25.6mA with FVMI, FVMV, FIMV, FIMI modes. 8 channel can be ganged to support high current driving.
-
product
PXI/PXIe Fault Insertion Switch, 32-Chan 2A, N/C Through Relays, Fault Buses on M & U
40-190C-212
The 40-190C-212 (PXI) and 42-190C-212 (PXIe) are fault insertion switches with 32 channels. They are part of a range of modules available with 74, 64 or 32 channels and are primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
product
PXI 10A Fault Insertion Switch 10-Chan 2-Bus
40-199-002
The 40-199 is a 10 Channel Fault Insertion switch designed for the simulation of fault conditions in automotive/avionics applications, involving the reliability testing of safety critical controllers.
-
product
PXI 5A Fault Insertion Switch 20-Chan 2-Bus
40-198-002
The 40-198 is a 20 Channel Fault Insertion switch, primarily designed for the simulation of fault conditions in automotive/avionics applications involving the reliability testing of safety critical controllers.