Line Replaceable Unit
unit of a complex engineered system, designed for quick replacement.
See Also: LRU
-
Product
Ethernet/AFDX/BroadR-Reach PXI Fault Insertion Switch - 8 Channel
40-201-008
Fault Insertion Unit
This high bandwidth differential PXI fault insertion module is designed to simulate common faults on high speed two wire communication interfaces such as Ethernet. This module supports 4 or 8-channels of two wire serial connections and can be used for simulating faults on Ethernet, AFDX, BroadR-Reach, 100BaseT and 1000BaseT interfaces. Any wire can be set to an open circuit, shorts can be applied across the wire pair, or to the adjacent pair. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to a supply voltage or ground. Each fault bus is capable of carrying 2A allowing multiple channels to be connected to the same fault condition. Additionally, each fault bus features a changeover relay to allow the user to connect alternative fault conditions to the fault buses.
-
Product
PXI 5A Fault Insertion Switch 5-Channel
40-196-101
Fault Insertion Unit
The 40-196 is a 10 Channel 5A Fault Insertion Switch, primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert different fault conditions between the test fixture and the equipment under test: Open-Circuit, Short-Circuit between signal pairs, Short-Circuit between signal pairs and user applied fault conditions e.g. Power or GND. Shorting relays on each channel enable UUT signals to be subjected to external user applied fault conditions or to be shorted to the adjacent signal in the same channel. Relays in line with the signal allow open circuit conditions to be simulated on either side or both sides of a channel signal pair. The switching topology of the 40-196 allows channels to be interconnected so that complex fault insertion systems can be constructed.
-
Product
PXI 22-Channel 2A Fault Insert Switches
40-202-001
Fault Insertion Unit
This is the 22 Channel version of the 40-202 Fault Insertion Switch. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. It is designed to be able to insert three different fault conditions between the test fixture and the equipment under test.
-
Product
PXI-2510, 68-Channel, 2 A PXI Signal Insertion Switch Module
778572-10
Fault Insertion Unit
68-Channel, 2 A PXI Signal Insertion Switch Module—The PXI‑2510 fault insertion unit (FIU) is designed for hardware‑in‑the‑loop (HIL) applications and electronic reliability tests. Each module has a set of feedthrough channels that you can open or short to one or more fault buses. You can use this architecture to simulate open or interrupted connections as well as shorts between pins, shorts to battery voltages, and shorts to ground on a per-channel basis. When controlled with the LabVIEW Real-Time Module, the PXI‑2510 is ideal for validating the integrity of control systems including engine control units (ECUs) and full authority digital engine controls
-
Product
PXI 10A Fault Insertion Switch 10-Chan 2-Bus
40-199-002
Fault Insertion Unit
The 40-199 is a 10 Channel Fault Insertion switch designed for the simulation of fault conditions in automotive/avionics applications, involving the reliability testing of safety critical controllers.
-
Product
Source Measurement Unit
PEMU4
Source Measure Unit
The PEMU4 represents a new level of performance and capabilities for USB-based SMU (Source MeasurementUnit) instrumentation. The PEMU4 supports -1V to +6.5V 0.5A with FVMI, FVMV, FIMV, FIMI modes. 4 channel can be ganged to support high current driving. I2C/SPI/RFFE function for serial port device testing. 4 Counter for frequency measurement.
-
Product
PXI 10GBase-T1 Ethernet MEMS Fault Insertion Switch, 8 Channel
40-205-008
Fault Insertion Unit
The 40-205-008 (PXI) is a 8-channel fault insertion switches designed to simulate common faults on high speed two wire communication interfaces such as xBaseT1 Ethernet. They available with 4 or 8 channels of two wire serial connections and can be used for simulating faults on 10BaseT1, 100BaseT1, 1000BaseT1 and 10GBaseT1 Ethernet interfaces. Any wire can be set as open circuit and shorts can be applied across wire pairs. Fault connections can be made to one of four external signals via two fault buses, typically simulating connections to supply voltage or ground.
-
Product
PXI Fault Insertion Switch, 7-Channel, One Fault Bus, 20 A, Hardware Interlock
40-193A-001-HI
Fault Insertion Unit
The 40-193A-001-HI is a 7-Channel Fault Insertion switch with hardware interlock and one fault bus, designed for the simulation of fault conditions in automotive systems. The module is capable of switching current up to 20A.
-
Product
PXIe 5-channel Source/Measure Unit, 500 kSa/s, 100 pA, 30 V, 500 mA
M9614A
Source Measure Unit
The Keysight M9614A is a PXIe five-channel source / measure unit (SMU). It supports accurate measurement up to 30 V / 500 mA with resolution down to 6 μV / 100 pA.
-
Product
PXIe-4141, 4-Channel, ±10 V, 100 mA, Precision PXI Source Measure Unit
781743-01
Source Measure Unit
PXIe, 4-Channel, ±10 V, 100 mA, Precision PXI Source Measure Unit - The PXIe-4141 is a 4-channel source measure unit (SMU) ideal for high-pin-count applications. It features 4-quadrant operation, and each channel has integrated remote (4 wire) sensing for accurate measurements. The fast sample rate of the PXIe-4141 can reduce measurement times, capture transient device characteristics, and allow quick I V characterization of devices under test (DUTs). With a high-speed sequencing engine, you can synchronize all these SMUs with each other or with other instruments such as switches or high-speed digital test modules. Additionally, you can tune the PXIe-4141 response to any load to achieve optimum responses with maximum stability and minimum transients using SourceAdapt technology.
-
Product
Precision Source / Measure Unit (2 Ch, 10 FA)
B2912B
Source Measure Unit
The Keysight B2912B precision source / measure unit (SMU) is a 2-channel, compact, and cost-effective benchtop SMU with the capability to source and measure both voltage and current. It easily measures current versus voltage (I/V) with high accuracy. The 4-quadrant source and measurement capabilities enable taking I/V measurements without configuring multiple instruments.
-
Product
Precision Source/Measure Unit, 1 Ch, 10 FA Resolution, 210 V, 1.5 A
B2910BL
Source Measure Unit
The Keysight B2910BL Precision Source / Measure Unit (SMU) is a 1-channel, compact and cost-effective bench-top SMU with the capability to source and measure both voltage and current. It is versatile to perform I/V (current vs. voltage) measurement easily with high accuracy. Integration of 4 quadrant source and measurement capabilities enables I/V measurement simply and easily without configuring multiple instruments.
-
Product
Source Measurement Unit
SMU4
Source Measure Unit
The SMU4 offers high voltage DPS in a compact, 3U PXI form factor. The SMU4 supports -20V to +20V 100mA with FVMI, FVMV, FIMV, FIMI modes.
-
Product
PXI Single Bus 32-Ch 2A Fault Insertion Switch, N/O Through Relays
40-190B-501
Fault Insertion Unit
The Single Bus, 32 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally open through relays, so in the default state, there are no paths between inputs and outputs for any signal channel. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
6U VME COTS System, Sensor Interface Unit
SIU6
Sensor Interface Unit
NAI's SIU6 is a highly configurable rugged COTS system or subsystem ideally suited for military, industrial, and commercial applications that require high-density I/O, communication, Ethernet switching, and processing. The SIU6 leverages NAI field-proven, 6U VME boards to deliver off-the-shelf, SWaP-optimized COTS solutions that "Accelerate Your-Time-to-Mission."
-
Product
Two-Quadrant SMU For Battery Drain Analysis, 20 V
N6781A
Source Measure Unit
The Keysight N6781A is a source / measure unit (SMU) designed specifically for the task of battery drain analysis. Whether the device under test (DUT) is an eBook reader, MP3 player, mobile phone, or pacemaker, the N6781A’s seamless measurement ranging, programmable output resistance, and auxiliary DVM combine the best set of advanced features on the market for battery drain analysis. When used with the 14585A Control and Analysis software, the N6781A becomes an even more powerful battery drain analysis solution, offering additional insights into your measurements. Learn more about the 14585A Control and Analysis software.
-
Product
Source Measure Units
NGU
Source Measure Unit
Thanks to their extremely high accuracy and fast load recovery time, the R&S®NGU source measure units (SMU) are perfect for challenging applications. A special ammeter design is used to precisely measure current drains from nA to A in one pass – no need to make multiple measurement sweeps. The instruments’ short recovery times enable them to handle fast load changes that occur, for example, when mobile communications devices switch from sleep mode to transmit mode. With high speed data acquisition, every detail is detected down to 2 μs resolution.
-
Product
Digital Source Capture Unit
DIO2
Capture Unit
The DIO-II module is a multimode digital source and capture unit. In Low Speed Mode it provides a 20-bit parallel or 24-bit serial I/O capability running at speeds up to 50 MHz. In High Speed Mode, the DIO-II provides a 16-bit parallel I/O capability up to 200 MHz. In both Modes, the Clock is generated by a low jitter PLL source that is capable of generating clocks from 320 kHz up to 1 GHz.
-
Product
USB Source Measure Units
Source Measure Unit
The U272xA is a 3-channel USB SMU that can operate in a 4-quadrant operation. It can function as a standalone module or used as a modular device, allowing expansion and compact solution when used with the other modules in the USB Modular Instruments and DAQ family.
-
Product
6x 3U OpenVPX MOSA Remote Interface Unit
SIU36-RIUVARM-01
Remote Interface Unit
SIU36-RIUVARM-01 is a Modular Open Systems Approach (MOSA) Remote Interface Unit (RIU) to manage, monitor and control connected I/O, communications, measurement and simulation interfaces through Ethernet commands from a main mission processors. Extremely low power with 2 x 10/100/1000Base-T Ethernet.
-
Product
PXI Dual Bus 64-Chan 2A Fault Insertion Switch
40-190B-102
Fault Insertion Unit
The Dual Bus, 64 Channel PXI Fault Insertion switch is part of our family of 2 Amp fault insertion solutions, The range includes modules with 74, 64 or 32 channels and single or dual fault buses. This version has normally closed through relays, so in the default state, there is a path between input and output for all signal channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers.
-
Product
USB Modular Source Measure Unit
U2722A
Source Measure Unit
The U2722A USB Modular Source Measure Unit is a 3-channel 20V/120mA that can operate in a 4-quadrant operation. The channels could be connected in series or in parallel to achieve up to 60 V/360 mA. It uses the common non-proprietary standard high-speed USB 2.0 interface that provides ease of connectivity allowing users to set up and configure their tests swiftly with its plug and play feature.
-
Product
Telephone Line Tester for ISDN Lines
1EA065
-
ISDN line checker shows the correctness of your ISDN So bus line connections. Indication of the problem is presented with 4 LED (combination of them shows different states and working conditions of the ISDN So bus). The tester uses Phantom power - no need for additional power supplay.
-
Product
Dual Bus 75-Channel 2A PCI Fault Insertion Switch
50-190-002
Fault Insertion Unit
This PCI fault insertion switch range is available with 75, 64 or 36 channels. It is primarily designed for the simulation of fault conditions in automotive & avionics applications involving the reliability testing of safety critical controllers. The Stimulus/Measurement to UUT path is suitable for supporting CAN and FlexRay bus systems.
-
Product
Electrical Clock Recovery
N1076B
Clock and Data Recovery Unit
The N1076B Electrical Clock Recovery provides standards-compliant clock recovery capability on electrical NRZ and PAM4 signals from 125 MBd up to 64 GBd
-
Product
PXI/PXIe 1000Base-T1 Fault Insertion Switch, 3-Channel
40-203-001
Fault Insertion Unit
The 40-203-001 (PXI) and 42-203-001 (PXIe) are designed to simulate common faults on high-speed two wire communication interfaces such as 1000Base-T1. They support 3 channels of two wire serial interfaces. Each channel pair can simulate an open fault in either or both wires, and using the fault bus switches can simulate short between both wires or a short to one of two externally applied fault connections – such as battery supply or ground - via two fault buses.
-
Product
Storage Unit
DM-U.2
-
The DM-U.2 PXI Express Storage Unit provides up to 7.68TB of removable solid state storage (SSD) in a single PXI Express slot. It addresses the requirements of users who need to remove and replace PXI Express storage for security or other reasons. This includes data recording applications where recorded media must be quickly removed and replaced with fresh media between recording missions. It also facilitates easy data removal for data security reasons when a system is left unattended.
-
Product
Line Protection
-
Schweitzer Engineering Laboratories, Inc.
SEL transmission line protection relays provide subcycle line differential and multizone distance protection for a secure, reliable, and high-speed solution. Their fault-locating capabilities allow you to efficiently dispatch line crews to quickly isolate line problems and restore service faster.