Hydrogen Frequency Standards
Microwave Amplification by Stimulated Emission of Radiation
See Also: Frequency Standards, Rubidium Standards, Hydrogen Masers
-
Product
Programmable S/R Standard & Simulator
5300
Simulator
NAI’s 5300 Synchro/Resolver Standard & Simulator is a laboratory-grade, programmable instrument. This model can be used as a true Synchro/Resolver standard for calibrating and testing Automatic Test Equipment (ATE) for Calibration/Metrology Labs, and for Engineering Design and Production Test environments. It can also be used to measure Angle Position Indicators (API) and Synchro-to-Digital converters for static or dynamic characteristics. This model also may use an external reference waveform.
-
Product
Four Terminal Pair Standard Resistor Set
42030A
Programmable Resistor Module
The 42030A is a standard resistor set consisting of nine precision resistor standards which range from 1 mΩ to 100 kΩ. These resistors are primarily used for performance tests of Keysight's 4-terminal pair LCR meters and impedance analyzers. Refer to the instrument's operation/service manual for the method of using these standards.
-
Product
5 Digit Frequency Meter
CS2-F
-
CS2-F Freqeuncy Meter is designed high accuracy measurement, display, control and communication (Modbus RTU mode) of pulse(Frequency) or AC Frequency.● The innovation feature is auto-range input from 0.01Hz~ 100KHz(~140KHz in option). The display resolution will be auto-changed to show the highest according to input frequency. They are also building in 4 Relay outputs, 3 External Control Inputs, 1 Analogue output and 1 RS485(Modbus RTU Mode) interface with versatile functions such as control, alarm, re-transmission and communication for a wide range of testing and machinery control applications. Please refer to the detail description on pages 2/33~7/33.There are not only controllers, but also an I/O interface in any system. ADtek built in difference ideal for External Control input and Relay output as like as I/O module of PLC. It’s very connivance to achieve remote monitoring and control by CS2 series.
-
Product
Standardize Production Test Software For PCBAs And Electronic Devices
test
The vast majority of test project man-hours are spent on software development, so the choices that teams make in software tools and architecture have significant impact on deployment schedules. Standardizing software across a team or organization increases both efficiency and proficiency, lowering the risk of missed deadlines and improving test quality and reliability. Test software must:
-
Product
Working Standard Shunts
CSW
-
CSW shunts are rated to 100 % continuous current with no loss of accuracy. They are largely immune from connection errors common to many shunts. All CSW shunts include ISO17025 accredited calibration through full current range.
-
Product
Standard CW Amplifiers
-
The BT-AlphaA-CW series is a range of classAB RF power amplifiers covering the 10kHz to1MHz frequency range. Rugged, solid-state design - high reliability. Extremely high phase and amplitude stability. High linearity. In-Built Protection. Very fast blanking. Capable of pulsed operation. Competitively priced. Suitable for CW radar, communications, HF/VHF jamming, particle accelerator applications/plasma systems, plasma, RF heating and other scientific applications.
-
Product
Digital High Frequency Surge Testers
C Model
-
These Digital High Frequency Surge Testers are the ultimate in ruggedness & durability. Fourteen / sixteen gauge steel construction and mobility on 6" heavy duty rubber wheels makes it a favorite for use in harsh industrial environments. The performance of PJ's exclusive/unique High Frequency Technology is capable of testing the integrity of any turn-to-turn insulation, including low inductance windings.
-
Product
Standard 1.71 (48.00) - 3.00 (85.00) General Purpose Probe
HPA-74T156
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Test Center Remark: max. test center 187 mil / 4,74 mmFull Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 75Recommended Travel (mm): 1.91Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 598Overall Length (mm): 15.19Overall Length Remark: Tip “A-B”: 598 (mil), 15.19 (mil), Tip “C”: 586 (mil), 14.88 (mil), Tip “E, T135, T156, T65, T80”: 610 (mil), 15.49 (mil), Tip “T75”: 620 (mil), 15.75 (mil)
-
Product
Process Hydrogen Analyzer
HY-OPTIMA™ 700B Series
-
H2scan’s HY-OPTIMA™ 700B series in-line, real time hydrogen-specific process analyzers are designed for ease of use, interface flexibility and true process control. The HY-OPTIMA™ 700B series is a solid-state sensor that is configured to operate in process gas streams with temperatures up to 60ºC. The HY-OPTIMA™ 700B series is ideal for hydrogen production and petrochemical applications where real-time measurements can enhance process plant efficiencies, diagnostics and maintenance management.
-
Product
High Frequency RF and Microwave USB Programmable Signal Generators
LMS Series
-
The Lab Brick LMS series of high frequency RF and microwave USB-compatible, synthesized signal generators cover a frequency range from 0.5 MHz - 20 GHz with low noise, fast 100-microsecond switching time, and fine 100 Hz frequency resolution. They require no additional DC supply voltage and offer advanced features such as phase-continuous linear-frequency sweeping, internal/external 10 MHz reference, and optional pulse modulation. GUI software can track and control several connected signal generators, simplifying multiple-signal test setups. Each device stores settings in internal memory, allowing it to power up in a specific instrument state.
-
Product
Dual Frequency 900 kHz & 2250 kHz 2D Imaging Sonar
BlueView M900-2250-130-Mk2
-
Your product description goes here.The dual-frequency 900 kHz and 2250 kHz provide the most versatility of any 2D imaging sonar. The 900 kHz offers high-resolution long range navigation, object detection, and obstacle avoidance, while the 2250 kHz provides ultra-high resolution at close range. ROV navigation, hull inspections, structure inspections, diver monitoring, and search and recovery are a few applications that benefit from the dual-frequency’s imaging capabilities.
-
Product
Standard 1.09 (31.00) - 4.50 (128.00) Long Travel Bead Probe
BPLT-1HL-4.5
Bead Target Probe
Current Rating (Amps): 6Average Probe Resistance (mOhm): 10Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,450Overall Length (mm): 36.83Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, High Spring: 350 mil / 8,89 mm
-
Product
High Frequency Clock Divider Board
-
Alliance Support Partners, Inc.
Clock Divider is designed to divide high frequency signals, up to 2.5GHz, from 4 to 256 times. It will accept single ended (Unbalanced) or differential (Balanced) signals with amplitudes as little as 100mV rms. The clock division is controlled by 4 shunt jumpers. The circuit can be disabled and the divide by counter reset with 2 control signals. The on board regulator will accept voltages from 4.85 to 15.0V. The output is capable of driving 700mV Peak to Peak into 50 Ohms.
-
Product
Standard Loggers
-
Our standard loggers can measure up to 13 parameters. Numerous configuration options allow for maximum customization for your measurement needs. In addition to our conductivity, temperature and depth sensors, many others, including third-party sensors, can be used with our recorders. Measure salinity. Measure tide and waves. Altitude & Attitude Logger.
-
Product
Standard 1.08 (31.00) - 4.00 (114.00) Long Travel Bead Probe
BPLT-25HL-4
Bead Target Probe
Current Rating (Amps): 8Average Probe Resistance (mOhm): 8Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 350Full Travel (mm): 8.89Recommended Travel (mil): 317Recommended Travel (mm): 8.05Mechanical Life (no of cycles): 500,000Overall Length (mil): 1,460Overall Length (mm): 37.08Full Travel Remark: Standard Spring: 400 mil / 10,16 mm, Alternate Spring 400 mil / 10,16 mm, High Spring: 400 mil / 10,16 mm, Ultra High Spring: 350 mil / 8,89 mm
-
Product
Frequency Converter
A6
-
The Quartzlock model A6 frequency converter precisely changes either 5 or 10MHz sine wave signals to a number of other frequencies from 1Hz and 1pps upwards to other standard frequencies.
-
Product
Standard Resistors for Temperature Measurement
-
Measurements International Ltd.
High Stability, Split Guard Circuit, Internal Temperature Sensor, Custom Values Available, Includes Calibration Data.
-
Product
Standard High Speed D/A Converters
-
Analog Devices digital-to-analog converter (DAC) portfolio provides solutions for your high speed and precision DAC applications. Thanks to complete data sheets and evaluation boards, as well as broad support among our clock and timing, RF, power management, and op amp portfolios, our DACs can help you reduce time to market and system design costs. A high speed range from 30 MSPS to multi-GSPS, 8- to 16-bit resolution, and a tiny package are just some of the features that make our industry-leading d/a converters stand out.
-
Product
UV/IR Flame Detector for Hydrogen Apps
-
The FL500-H2 is an Ultraviolet / Infrared flame detector designed specifically to detect hydrogen (H2) fires. The FL500-H2 optical flame detector monitors for radiation emitted by a hydrogen flame in both the ultraviolet (UV) and infrared (IR) spectral ranges.
-
Product
Frequency Multipliers
-
A series of broadband frequency multipliers is available with output frequencies between 18 and 110 GHz. The use of GaAs diodes on a suspended substrate circuit allows an extremely compact device. Circuit symmetry is used to enhance either even or odd harmonics while suppressing unwanted odd or even harmonics. These devices can be used as higher order even or odd harmonic multipliers with reduced efficiency. All of these multipliers have maximum input power +23 dBm for temperature less than +50°C.
-
Product
Standard 1.10 (31.00) - 2.50 (71.00) General Purpose Probe
HPA-1A
General Purpose Probe
Current Rating (Amps): 3Average Probe Resistance (mOhm): 35Test Center (mil): 75Test Center (mm): 1.91Full Travel (mil): 100Full Travel (mm): 2.54Recommended Travel (mil): 67Recommended Travel (mm): 1.70Mechanical Life (no of cyles): 1,000,000Overall Length (mil): 655Overall Length (mm): 16.64
-
Product
Ultra-Low Frequency Raman Spectrometer Down to 10 cm-1
Modular TeraHertz Raman Spectrometer
-
HORIBA’s modular terahertz modular Raman spectrometer extends the spectral range of a measurement to < 10 cm-1. Consisting of an Ondax SureBlock™ module fiber coupled to HORIBA’s iHR320 imaging spectrometer, this custom system provides an affordable option for macro-Raman measurements close to the laser line. Below are Stokes and anti-Stokes spectra of elemental sulfur recorded with this system.
-
Product
Standard 1.08 (31.00) - 3.50 (99.00) General Purpose Probe
EPA-2F
General Purpose Probe
Current Rating (Amps): 5Average Probe Resistance (mOhm): 35Test Center (mil): 100Test Center (mm): 2.54Full Travel (mil): 160Full Travel (mm): 4.06Recommended Travel (mil): 107Recommended Travel (mm): 2.72Mechanical Life (no of cyles): 2,000,000Overall Length (mil): 970Overall Length (mm): 24.64
-
Product
Radio Frequency (RF) Testing
-
Comprehensive testing and certification services helping you ensure that your wireless or radio devices achieve compliance to international regulatory RF or immunity requirements.
-
Product
Uniform Light Sources, Luminance Standards
-
Uniform light sources for the adjustment of pixels and intensity of image sensors and cameras as well as for the calibration of luminance and spectral radiance or in other words: Solutions for Imaging, Sensing & Remote Sensor Calibration.
-
Product
Frequency Converter Test Solution Up To 50 GHz
N5245BP
-
The N5245BP provides the N5245B 50 GHz PNA-X network analyzer, application software and accessories for frequency converter test up to 50 GHz. This bundle product
-
Product
Frequency Response Analyzers
-
Frequency Response Analysis (also referred to as Transfer Function Analysis) measures the output spectrum of a system relative to a stimulus, and is used to characterize the dynamics of the system under test. The technique measures the magnitude and phase relationship between output and input waveforms as a function of frequency. The input signals may be from a wide range of sensors including acoustic (microphones/sonar), mechanical (accelerometers/displacement transducers), optical (photodetectors), and electrical (amplifiers).
-
Product
Standard Electromagnetic Vibrator
KD-9363-EM
-
King Design Industrial Co., Ltd.
The purpose of vibration testing is to make a series of controllable vibration simulation in lab, no matter generated by natural or man-made vibration environment; such as waves, tidal flaps, wind, earthquake or rain and so on. It is to test if the product is capable of sustaining the vibration environment exerted from transporting or usage along its effective life cycle; and certify the standard of design & functional requirement of product. The value of vibration testing is to confirm the reliability of products and effectively screen out the bad products in factory; avoiding damages occurred at arrival; and to assess the failure analysis on the non-performing products; expecting to reach a high standard, high-reliability products. The vibration test stresses on the continuity and fatigue; and contributes to the understanding of product’s status under vibration circumstance in a normal environment; and avoids the product’s unpredictable damage caused under certain vibrating frequency for a long time.
-
Product
Adjustable High Frequency Reference Ballast
HCS-109A
-
HCS-109A Adjustable High Frequency Reference Ballast also called High Frequency Current Source. Comparing to IEC Test Method, HCS-109A is an Equivalent Test Method which is economic solution. HCS-109A equipped with Spectrophotometer & Integrating Sphere Test System. It can also measure the photo, color and electricity parameters for high frequency fluorescent lamp.Specifications: • Input voltage: 200V~240V, 50/60Hz • Input Power: 80 W max • Output Current: 130mA~400mA (Adjustable), accuracy: +/- 1% • Output Frequency: 25kHz< +/-2.0% (Adjustable), accuracy: +/- 0.3kHz • Output current total harmonic wave distortion: THD<2.5% (HF current wave)
-
Product
Standard 6.20 (175.20) - 8.00 (226.80) High Frequency Probe
CSP-40A-015
High Frequency Probe
Bandwidth @ -1dB (GHz): 6.00Return Loss @ -20dB (GHz): 2.30Nominal Impedance (Ohms): 50Dielectric VTE Rating (k VAC): 1Test Center (mil): 250Test Center (mm): 6.35Full Travel (mil): 200Full Travel (mm): 5.08Recommended Travel (mil): 133Recommended Travel Remark: Shield: 211 (5.36) including travel of probesOverall Length (mil): 1,231Overall Length (mm): 31.28Full Travel Remark: Shield: 275 (6.99) including travel of probes