CT
1) Current Transformer 2) Computed Tomography
-
Product
Crack Opening Displacement (COD) gauges
COD
-
Instron® Crack Opening Displacement transducers are designed specifically to perform standard ASTM and ISO fracture mechanics tests (both cyclic and static), covering all common specimen geometries (CT, SEB, Centre Crack, Arc Shaped). Each model offers class leading linearity, whilst being rugged enough to withstand the high energy release common in many of these applications and can be used at both elevated and sub-ambient temperatures. These gauges comply with requirements laid down in ASTM E399-09.
-
Product
CT/PT Test Set
PCT200Ai
-
PCT200Ai is the CT/PT test set (current transformer analyzer) that can finish various current transformer test of different CT and plus reference testing functions of PT. Compared with PCT200i, its accuracy is higher.
-
Product
Non-contact Io/Ior Leakage Clamp Meter
MCL-500IRV
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Safety by non-contact sensor, not touching live part directly (prevention of electric shock, short-circuit, etc.).・Easy to carry and operate, clamp CT + display part integrated type.・Measurable line current + leakage current + resistive leakage current by one unit.・Available direct voltage input at live part as ordinary.・True RMS measurement (I, Io, V).・With filter switch to cut high frequencies.
-
Product
Customaizable Uninterrupted Power System
CT Series
-
The rugged CT Series is designed for applications in extreme temperature environments, such as offshore drilling rigs, refineries and shipboard use. An added benefit is that the CT Series can double as an electronic power conditioner/frequency converter as well. All CT systems utilize Power Factor Correction, and RS232 and SNMP protocols are supported.
-
Product
GAOTek Three-Channel Leakage Current Tester
GT00YB00ZV
-
The GAOTek Three-Channel Leakage Current Tester provides online measurement, monitoring, and recording of three channel AC leakage currents simultaneously by adopting the latest CT and magnetic shielding technology. This instrument provides highly accurate and reliable measurements. Additionally, it can locate insulation faults and repair electrical lines. It is composed of a special alloy and consists of a test monitoring software, current clamp, and communication cable. The instrument can store 3900 sets of data and enables online and real time monitoring, historical data inquiry, read, inquire storage, generation, and printing of a fitting curve. It is widely used in 380/220 power systems. It complies with IEC1010-1, IEC1010-2-032, Pollution Class 2, CAT Ⅲ (600 V), and IEC61326 (EMC standard) safety codes.
-
Product
Software Packages
GLUON
-
The software uses notched specimens (CT specimens) to evaluate the material elasto-plastic fracture toughness value (JIC). The test is conducted at constant loading rate under test-force control or CTOD control and the load is removed to calculate the crack length. The software plots graphs of the crack length increase (Δa) and crack growth resistance (J value) from the acquired data, calculates the JIC value, and evaluates its validity.
-
Product
Capacitor Tester
MIG0603CAP
-
The MIG0603CAP consists of two circuits with impulse capacitance 20 µF and 0,25 µF. Both circuits generate a voltage wave shape 1,2/50 µs and are combined in a 4 unit height 19" rack. The generator circuits are defined in IEC 60384-14 and EN 132400. The serial resistors Rs, the impulse capacitor CT, and the load capacitance Cp will be automatically switched when different capacitance ranges are selected on the MIG0603CAP.
-
Product
6U CompactPCI Enclosures & Systems
-
1~9U CompactPCI chassis for 6U CompactPCI boards , most of which are with front/rear panel I/O, H.110 CT bus and redundant power supplies.
-
Product
Clamp type AC Current Sensor/for Leakage Current Measurements(ZCT Series)
ZCT-80
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Leakage current measurements of main cable*BIG CT WINDOW*AC 1mA~500A
-
Product
Industrial CT X-Ray Inspection System
X3000
-
The X3000 is North Star Imaging’s newest standard system. Whether you are inspecting small or large components, the X3000 is the best option for customers needing a compact system with unique capabilities generally available on a larger X-ray or CT system.
-
Product
Plugless Solutions
-
Operation based on the insertion of disconnect pins with embedded CT shorting, which isolate field equipment from the relay.
-
Product
AC Current Clamp Adapter
LAD-1100
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
●Selectable measuring range 30mA~30A with CT ratio 10:1 and 30A~3000A with CT ratio 100:1.●φ110mm CT window, possible to measure from leakage to big current up to 3000A.
-
Product
Wireless Energy Datalogger
ELITEpro XC™ Energy Logger
-
The ELITEpro XC is a complete solution for pinpointing electric usage and recording building performance metrics. It is capable of measuring, storing, and analyzing electrical consumption data which is derived from the voltage and current inputs. The ELITEpro XC uses direct connections to each phase of the voltage and various interchangeable CT options such as split-core current transformers, or flexible RoCoils (for large loads or large cables and bussbars) to monitor current on each phase.
-
Product
Standard CT
6300A
-
The Model 2509 Instrument Current Transformer is a 6300 A ampere CT designed for precision measurement of AC current or for Instrument Current Transformer calibration applications. The CT can be installed on a bus bar or it can be used with a primary conductor consisting of number of turns. The 6300 CT is designed with a tapped primary & a tapped secondary winding, thus providing a large number of ratios over a range of 5 to 6300 amperes.
-
Product
Leakage Current Clamp Tester with Bluetooth40mmφCT, ACA
M-1141X
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Waveform display is possible with connection to a smartphone・Measurement data is to be accumulated in the server, and it is available for graph and CSV output・Auto 5-range : AC 30mA / 300mA / 3A / 30A / 300A・CT inside diameter : φ40mm・Minimum resolution : 0.01mA・Maximum value hold / Data hold function available・Band path filter with center frequency (fo = 55Hz)・Compliant with EN 61010, CAT-III 1000V / CAT-IV 600V・With backlight
-
Product
NI-9246, 50 kS/s/ch, 20 Arms, 30 Apk, 24-Bit, 3-Channel C Series Current Input Module
783920-01
Current Input Module
50 kS/s/ch, 20 Arms, 30 Apk, 24-Bit, 3-Channel C Series Current Input Module - The NI‑9246 is designed to support direct ring lug connectivity to the three-phase high-current measurements of 1 A and 5 A current transformers (CTs). It is optimized for power, energy, and industrial applications. The safety features, certifications, input ranges, overvoltage ranges, and connectivity are well suited for applications such as power quality monitoring and metering, utility pole-mounted smart switches, utility pole-mounted smart grid reclosers, substation merging units, industrial machine measurements, health monitoring, predictive maintenance and prognostics, and phasor measurement units (PMUs).
-
Product
Instrument Transformer Calibrators
CTPT 81
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
Tests: Ratio error. Excitation current and curve. Polarity CT / PT TESTER
-
Product
Current Transformers & Bushings
-
Measurements International Ltd.
AC Current Transformer, Reference Standard for the Calibration of Precision CTs, Currents as high as 10,000 A, Portable with carrying handle for smaller CTs, Wheels on heavier CTs, Passive or Electronically Aided Compensation.
-
Product
Three-Phase Transformer Demagnetizer
DEM60C
-
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores. The best way to eliminate this source of potential problems is to use demagnetizer on the power or instrument transformer.The DEM60C is a fully automatic test instrument which performs three-phase transformer demagnetization. Transformer magnetic core demagnetization requires the application of AC current with magnitude decreasing to zero. DEM60C provides this AC current by internally changing the polarity of a controlled DC current. During the demagnetization process, the instrument supplies the current at decreasing magnitude for each step, following a proprietary algorithm. It can demagnetize single-phase and three-phase power transformers.The instrument can be connected to all three phases of a power transformer to be demagnetized, on either the primary or the secondary side. If a user selects specific vector diagrams for different types of transformers, DEM60C will run a specific demagnetization procedure for each transformer type (i.e., single phase, delta, wye/star, zig-zag.) without switching the test leads.DEM60C enables safe and efficient power transformer demagnetization. The instrument automatically regulates the injection of current and discharging energy from the inductance. During and after the operation, an intrinsically safe discharge circuit with an indicator rapidly dissipates the stored magnetic energy. The discharging circuit is independent of the power supply, which improves its reliability in case of loss of power.Test currents of up to 60 A DC enable efficient demagnetization of even the largest power transformers. Using a DV Win software, it is possible to control DEM60C externally.
-
Product
Inline 3D-CT Automated X-ray Inspection Systems (3D-AXI)
3Xi Series
-
Saki's 3D-AXI (X-Ray) series adds significant inspection capability. The system utilizes Planar Computed Tomography (PCT) providing high precision CT imaging at high speed.
-
Product
Industrial CT X-Ray Inspection System
X25
-
The X25 is quite possibly the most conveniently sized industrial CT system on the market. The system offers all of the same features as the larger systems while still maintaining the ability to fit through a standard interior door. The X25 is well suited for small to medium sized objects.
-
Product
Biomagnetic Devices
-
Electrical measurements of physiological potentials are well established in clinical diagnostics. The flow of an electrical current creates a corresponding magnetic field. Thus bioelectric activity will generate biomagnetic fields. These fields can be detected with Tristan SQUID magnetometers. For many of the classical electrical techniques such as ECG and EEG, there are corresponding magnetic techniques (magnetocardiography or MCG and magnetoencephalography or MEG). In some cases (magnetopneumography, hepatic iron store measurements, intestinal ischemia, peripheral nerve and muscle activity), there is no corresponding electrical technique and biomagnetic measurements offer unique measurement capabilities. Unlike CT or MRI imaging which yield structural information, biomagnetic measurements offer real-time functional imaging.
-
Product
Generator Monitoring Unit
-
Avoids the requirement of 2 different meters (energy and VAF in one)Reduces the cost and simplify wiringHigh resolution reading with auto scaling in LEDEnergy consumption in counter even if CT is reversed
-
Product
Non-contact Io/Ior Leakage Clamp Meter
M-340IRV
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
・Safety by non-contact sensor, not touching live part directly (prevention of electric shock, short-circuit, etc.).・Easy to carry and operate, clamp CT + display part integrated type.・Measurable line current + leakage current + resistive leakage current by one unit.・Palm size mini clamp type.・High accurate measurement with min. resolution 0.001mA.
-
Product
Clamp type AC Current Sensor/for Power Monitor
CT-80PB
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*BIG CT WINDOW*AC 1A~500A*Current measurements of main cable
-
Product
Configurable CAN, LIN And CAN FD Data Logger
Rebel CT CAN FD
-
The Influx Rebel CT CAN FD is a compact data logger with gateway functionality and is an ideal choice for applications that requires vehicle CAN 2.0, CAN FD and LIN network data.
-
Product
Relaying Current Transformer Analyser
-
*Measures Ratio, Excitation Characteristics, Polarity, Winding Resistance, Remanance, and Insulation Resistance of secondary winding. * Determines Composite Error. * Used to test un-mounted CTs or CTs that are mounted but isolated inside the power system equipment. * Conducts a whole series of tests automatically, thus speeding up the time to commission CTs and relaying systems. * Battery powered test set - light weight & fully portable. * Provides a graphical presentation of the CT excitation characteristics. * Determines the IEC 10/50 knee point and the point of maximum permeability, ANSI 45 degree Slope Point. * Detects shorted turns or insulation problems within the test CT, thus avoiding commissioning of faulty equipment.
-
Product
Large Current 1000A Primary Current Injection Test Set
TEST-901
-
Beijing GFUVE Electronics Co.,Ltd.
TEST-901 primary current injection test set adopts ARM Chip to control its output process and large capacity of toroidal transformers. It is equipped with LCD display and current meter; it can show primary current value, second current value, turn ratio and the action time. Packing is used as aluminum alloy body with PC panel. TEST-901 is mainly applied to CT turn ratio testing in the power system and contact resistance test which need large current.
-
Product
Digital Clamp Tester With 80mm X 74mm CT With Bluetooth40mmφCT, ACA
MCL-800DX
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
Next-generation leakage current clamp meter with connection, via Bluetooth, to a smartphone which displays waveforms and data.
-
Product
ANSI Relaying Current Transformer Burden
-
The ANSI Current transformer burden is designed for loading the current transformer during accuracy Tests. The ANSI burden is designed as per ANSI burden C57.13.It can be used along with the Eltel Automatic Instrument Transformer Test Set to test CTs as per ANSI Standards.