CT
1) Current Transformer 2) Computed Tomography
-
Product
Detector of Earth Faults on Multi/Single-Core Terminations
CableTroll 2310
-
CableTroll 2310 is an indicator for detection of earth faults (PtG) on multi-core and single core cable terminations. The unit uses NorTroll type current sensor (CT)
-
Product
MXI X-Plane System
-
X-Plane technology provides high resolution, high magnification CT functionality anywhere on the board - without cutting the board.
-
Product
Ratiometers
-
Our digital measuring bridge offers exceptional accuracy for direct measurement of the transformation ratio and phase error of all types of energy transformers, autotransformers (single-phase and three-phase), as well as CT, PT and CVT measuring transformers.
-
Product
Transformer Analyzer
505
-
The UTEC 505 Transformer Analyzer is designed for testing current transformers (CT) and potential transformers (PT) without interruption of the customer’s service. This instrument measures CT admittance, CT ratio, CT primary-to-secondary phase angle and the voltage, current and phase angle of the service. With the ‘Burden CT/PT Option’, it determines the CT secondary burden capability, the regulation of the PT and its secondary burden capability and provides for CT core demagnetization.
-
Product
3CT Method Clamp Tester
MCL-4000F
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*3CT method enabled easy AC leakage current measurements with simple clamping of each phase conductor by 3 CTs or 4 CTs.*Use 4 CTs for 3phase/4wire power system.*Load current measurements for each phase conductor up to AC 800A.*Filter rejection for high frequency noise.*DC mV output for recorder.
-
Product
High Accuracy Clamp Leaker
-
Leakage Current Clamp Meter, Car Standby Current Clamp Meter, Car Inrush current Tester, Car Charge Current Tester. It is specially designed for online measurement of AC/DC leakage current, current below 600V by adopting up-to-date CT technology and digital integration technology. It is especially suitable for measure car standby current, leakage current, inrush current. It is a product with the characteristic of relatively small size, high accuracy, strong anti-interference capability and automatic shifting.
-
Product
Biomagnetic Devices
-
Electrical measurements of physiological potentials are well established in clinical diagnostics. The flow of an electrical current creates a corresponding magnetic field. Thus bioelectric activity will generate biomagnetic fields. These fields can be detected with Tristan SQUID magnetometers. For many of the classical electrical techniques such as ECG and EEG, there are corresponding magnetic techniques (magnetocardiography or MCG and magnetoencephalography or MEG). In some cases (magnetopneumography, hepatic iron store measurements, intestinal ischemia, peripheral nerve and muscle activity), there is no corresponding electrical technique and biomagnetic measurements offer unique measurement capabilities. Unlike CT or MRI imaging which yield structural information, biomagnetic measurements offer real-time functional imaging.
-
Product
Multi Circuit Leakage Current Monitor
MCM-8000
-
By connecting optional CT sensors, the instrument can measure and memorize leakage current of 8 circuits at the same time and the memorized data can be seen even during measurement.
-
Product
CT / PT Analyzer
CTPTA-504
-
UDEYRAJ ELECTRICALS PRIVATE LIMITED
UDEY ‘CTPTA-504 is a comprehensive CT and PT analyzer. It’s constant voltage and current is highly stable. DSP system controls the constant voltage and current source output and amplitude. This source generates AC of 0-125V and or DC of 0-0.5A current to sample CT. The DSP system besides controlling the sources, also samples data and communicates with the internal computer. Display screen is large LCD with touch pad. The analyzer is highly accurate with high noise immunity and is very user friendly.
-
Product
LCD Power Meters
-
Accuracy ±0.1% F.S. Measuring and display ACV/ACA/Watt/Var/VA/Power Factor/Frequency/KWH/DM(Demand) Input measurement network can be selectives(1P2W/1P3W/3P3W/3P4W) CT rate/PT rate can be modified(1 to 9999) Measuring ACV/ACA total harmonic distortion(THD),up to 35th harmonic(optional) Two alarm control function (optional) Two pulse output function (optional) Digit RS-485 interface function (Optional)
-
Product
Digital Power Meter, 30A
66205
-
Chroma Systems Solutions, Inc.
Voltage Ranges:15/30/60/150/300/600 Vrms1200Vrms (optional)Current Ranges : 0.005/0.02/0.05/0.2/0.3/0.5/2/5/20/30 ArmsFrequency Range : DC, 15Hz~10kHzEmbedded high speed DSP, 16 bitsAnalog/Digital converters withmax samipling rate up to 250kHzCapable of meeting the IEC 61000-4-7harmonics measurement requirementsSmart Range function provides seamlesspower integration measurement underauto range modeSupports external shunt and CT forhigher current applications5 mA minimum current range &0.1mW power resolutionMeets ENERGY STAR /EN 50564/IEC 62301/ErP requirementsUser-define criteria providesautomatic PASS/FAIL indicationsTHD and user-specify order distortionmeasurementInrush current and energy measurementsVoltage/ Current harmonics measurementsup to 100 ordersUSB (Host) interface provides data loggingfunctionalitySupport GPIB, USB, RS232, LAN (option)interface
-
Product
DR software, for use with CT100 Series TDRs
CT Viewer™
-
CT Viewer™ is a full-featured TDR waveform analysis software package for Microsoft® Windows® XP / Vista PCs that lets you archive, manipulate, analyze, and compare TDR data acquired with CT100 Series Automated Metallic TDRs or any other TDR instrument, now with live internet streaming and remote control of CT100 Series TDRs. CT Viewer™ is included with CT100 Series TDRs. Read on to discover how CT Viewer™ will change the way you test cables.
-
Product
CT-NANO
-
The CT-NANO is a fully operating scanning electron microscope with capabilities of Nano-CT measurements on specimen like light-metal-alloys and fiber composites.
-
Product
Digital Arrester Clamp Tester
ALCL-40
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*ALCL-40 is designed to test the diagnostic of OXIDE SURGE ARRESTER.*The least influence from the external magnetic field and noise by triple shielding of CT.*Compliant with IEC6099-5.*Enabled the measurements for 100nA resolution and harmonics current.
-
Product
High Current Comparators And Power Supplies
-
Designed in 3D, this custom unit fills the gap between the comparator manufacturers and the production floor. Vidac Solutions does not manufacture CT Comparators, but this unit (and others like it) are used to provide the complex high-current switching, buss-work, source current supply into an enclosure that fits into the production line and provides a safe, ergonomic and easy to use machine for the operators.
-
Product
AC/DC Mini Digital Clamp Tester (CE)
M-280
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
30mmφ CT window and ultra compact size. Conform to IEC safety requirements. Low cost and multi-function clamp tester. Max. and Min.hold function. Data-hold function and auto power off. Auto zero adjustment for DC current offset.
-
Product
Transformer Demagnetization Tester
-
Weshine Electric Manufacturing Co., Ltd
After a DC current test, such as winding resistance measurement, the magnetic core of a power or instrument transformer may be magnetized (remnant magnetism). It can cause various problems such as wrong diagnostics, inaccurate measurements on a transformer, inrush current at the start-up of a power transformer, or incorrect operation of protective relays due to magnetized CT cores.
-
Product
Current to Digital
-
Analog Devices’ breakthrough current-to-digital converter technology is backed by award winning expertise to help solve your medical, industrial, and security application needs. Our high speed, high resolution ADC modules enable improved CT scanner data acquisition, photodiode sensors and power monitoring, spectroscopy, and high channel count data acquisition systems.
-
Product
Flexible Leakage/Line Current Tester
RLM-10+
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
●Low-pass filter equipped, it can be cut the noise which is over 150Hz frequency.●Even Coreless Coil but Least Influence from External Magnetic Field and Residual Current●Superior Flexible CT enables Leakage Current Measurement●Backlight Function useful for measurement in the dark place
-
Product
AC Current Clamp Adapter
LAD-800
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
●Selectable CT ratio 10:1 and 100:1.●φ80mm CT window, possible to measure from leakage to big current up to 1000A.
-
Product
Industrial CT X-Ray Inspection System
X7000
-
The X7000 is North Star Imaging’s largest standard system. The large scanning envelope and generous focal distance allow for unparalleled inspection capabilities of very large objects. The system is great for composites, castings, pipes, tubes, welds and similar parts.
-
Product
Primary & Secondary Current Injection Testing Sets
-
Primary current injection kits are used to test and commission Circuit Breakers, Bus Bars, CTs, Relays, MCCs, PCCs etc. These are also used for high current injection and simultaneously measuring voltage drops and hot spots in bus-bar joints, Circuit Breaker Contacts etc.
-
Product
Synchro Power Amplifiers
SSP
Amplifier
Computer Conversions Corporation
The SSP Series are Compact, Reference Powered and Isolated Synchro Power Amplifiers, and AC Sine/Cosine ( Resolver ) to synchro converters; designed for moderate wattage, and re-transmission requirements; providing ultra high efficiency, and ultra high reliability in service, and ease of use. They are ideally suited for demanding Naval/Maritime, Aircraft, and Radar/Antenna related, applications. They are commonly used on synchro based data transmission, retransmission, simulation, and active control systems. They are suitable to drive both CT and CDX type passive loads, and virtually any synchro input instrumentation, or control.
-
Product
CT Admittance Tester
505B
-
Red Phase Instruments Australia Pty Ltd.
Field testing kWh meters is easy, field testing CTs when live is much more difficult. Our admittance tester can test CTs live with 50Hz or 60Hz current in the metering circuit. This technique does not confirm the accuracy of a CT but it will detect faults that give metering errors, such as shorted turns, metering circuits shorted to ground and tampering of CTs. CT faults can cause large revenue losses. Admittance testing only adds 10 minutes to a routine polyphase meter test, giving cheap insurance.
-
Product
3D CT Micro-Tomography And High Resolution Digital Radioscopy
DeskTom
-
Compact system with no maintenance. 5 motion axis. Small footprint.
-
Product
X-ray Inspection System
X-eye SF160 Series
-
High-performance Micro-focus Open Tube with 160kV is installed and fine defects of 1㎛ are detectable. High-resolution X-ray image can be gained with world best magnification by installing high-price Open Tube as standard.Dual CT function can be purchased adtionally, and exact location & size of defects can be detected and analyzed with this function.
-
Product
Multifunction Substation Test Set
STS 5000
-
STS 5000 is a multifunction substation maintenance & commissioning test system for current, voltage and power transformers designed to perform primary tests requested in substations commissioning. It allows to perform accurate tests on CTs, VTs, PTs and ground grid.
-
Product
CT/PT Analyzer
-
KINGSINE Electric Automation Co., Ltd.
Portable test set designed to assess the performance, accuracy, and health of Current Transformers (CTs) and Potential Transformers (PTs) in power systems.
-
Product
AC Current Isolated Sensor Two / Four Wire Transducer
TSCT (Average Sensing) / TFCT (TRUE RMS)
-
Kusam Electrical Industries Limited
• Transform Input: AC 5~400A directly into DC 4~20mA, no need external CT.• Suitable for application with high waveform distortion :(Frequency converter, Motor, SCR )• High accuracy <0.5%• High response time• High stability, easy connection.
-
Product
Secondary Current Injection Test Trolley
-
SCR ELEKTRONIKS have developed SECONDARY CURRENT INJECTION TEST TROLLEY for Switchgear items, CT manufacturer and where three phase current application is called for. It is low Voltage, 3 phase Current source with control circuitry, digital read out for test current and trip time measurement. We can select different CT ranges for each phase independently and adjust the current as per the required test Current.