Showing results: 961 - 975 of 1960 items found.
-
DX Series -
Cytec Corp.
Cytec's DX Series Switching Systems are based on solid state switch fabric. All systems are non-blocking (any input to any output) and full fan-out (any input to any or all outputs)The DX/256x256 systems are designed to switch TTL, CMOS, LVTTL, IRIG, RS232 and RS422 up to 80 Mbps NRZ. Input and output buffers are used to convert to RS422 and/or RS232 signal levels as needed.The DXM/64x64 and DXM/128x128 are modular systems capable of switching data rates to 3.2 Gbps NRZ. They are intended to switch RS422, ECL, PECL, LVDS, CML and virtually any type of digital data stream. Configurations as large as 128x128 Clock and Data systems can be easily configured.The DX/64x64 is an earlier version of the DXM and offers systems up to 64x64 with SMA connectors for ECL, PECL, LVDS or RS422.
-
GX6384 -
Marvin Test Solutions, Inc.
The GX6384 3U PXI multiplexer switch card provides users with the ability to switch and interface tester resources to multiple UUT connections. The card is available in three different configurations, supporting 32 x 2, 32 x 4, and 32 x6 switch configurations.
-
40-837-001 -
Pickering Interfaces Ltd.
The 40-837-001 is a 75Ω 2x2 RF matrix with 1 bank in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40-837 modules.
-
40-837-101 -
Pickering Interfaces Ltd.
The 40-837-101 is a 75Ω 2x2 RF matrix with 1 bank in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40-837 modules.
-
40-837-002 -
Pickering Interfaces Ltd.
The 40-837-002 is a 75Ω 2x2 RF matrix with 2 banks in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40-837 modules.
-
40-837-102 -
Pickering Interfaces Ltd.
The 40-837 is a 75 2x2 RF matrix available with 1 or 2 banks in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40-837 modules.
-
40-877-001 -
Pickering Interfaces Ltd.
The 40-877-001 is a 50Ω 2x2 RF matrix with 1 bank in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40-877 modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
40-877-101 -
Pickering Interfaces Ltd.
The 40-877-101 is a 50Ω 2x2 RF matrix with 1 bank in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40-877 modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
40-877-002 -
Pickering Interfaces Ltd.
The 40-877-002 is a 50Ω 2x2 RF matrix with 2 banks in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40-877 modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
40-877-102 -
Pickering Interfaces Ltd.
The 40-877-102 is a 50Ω 2x2 RF matrix with 2 banks in a single PXI slot. Loop-thru connections are provided on both the X and Y axis allowing the attachment of terminations for unused signals or for expansion to other matrices. Larger matrices are easily built with varied X and Y dimensions, such as 8x2 and 4x4 using multiple 40-877 modules. The module has low insertion loss and VSWR through the use of modern RF relay technology at an affordable cost.
-
40-587A-001 -
Pickering Interfaces Ltd.
Our model 40-587A, along with the following models40-584, 40-585, 40-586Aare high-density single pole PXI matrices each supporting 256 crosspoints. All models use gold-plated contact electromechanical relays. The PXI matrix modules are designed for switching medium voltage and power signals. The user signal connection is via a robust 78, 50 or 37 pin D-Type or 160 pin DIN 41612 connector that is fully supported by the wide range of our cable and connector accessories.
-
M9122A -
Keysight Technologies
The M9122A is an 8x32 full crosspoint switch matrix offering high-voltage switching in a high-density PXI module. This module allows for higher voltage switching of multiple channels in a single instance. Any row can be connected to any column, making it ideal for routing instrument signals to the device under test. This module is configured with a common ground. The durable armature switches are capable of switching up to 100Vrms, with up to 60W of power. The 8-wide bus can be used to route signals between your instruments and the device under test. Choose from the durable connector block or standard cable connections.
-
781420-34 -
NI
8x34, 2 A, Electromechanical Relay Matrix Module for SwitchBlock - The SWB‑2834 is an electromechanical relay matrix card for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
781421-34 -
NI
8x34, 2 A, Electromechanical Relay Matrix Module for SwitchBlock - The SWB‑2834 is an electromechanical relay matrix card for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.
-
781421-33 -
NI
4x71, 2 A, Electromechanical Relay Matrix Module for SwitchBlock - The SWB‑2833 is an electromechanical relay matrix card for SwitchBlock systems. Designed for high power, it can operate as an individual relay card or expand in a single carrier or single PXI chassis. You can connect any input to any output, individually or in combination. You can use matrix switches to route signals from oscilloscopes, DMMs, arbitrary waveform generators, and power supplies to various test points on a unit under test (UUT). The primary benefit of matrix switches is simplified wiring—the overall test system can easily and dynamically change the internal connection path without any external manual intervention.