Showing results: 196 - 210 of 1965 items found.
-
40-512-021-S -
Pickering Interfaces Ltd.
The 40-510 series of matrix modules feature a wide range of selectable switchingconfigurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signalrouting in ATE and data acquisition systems.Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screenedversion is suitable for switching signals up to 50MHz. Larger matrices may be constructedby Daisy Chaining the common signals from multiple PXI modules.
-
40-512-021 -
Pickering Interfaces Ltd.
The 40-510 series of matrix modules feature a wide range of selectable switchingconfigurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signalrouting in ATE and data acquisition systems.Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screenedversion is suitable for switching signals up to 50MHz. Larger matrices may be constructedby Daisy Chaining the common signals from multiple PXI modules.
-
40-510-022 -
Pickering Interfaces Ltd.
The 40-510 series of matrix modules feature a wide range of selectable switchingconfigurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signalrouting in ATE and data acquisition systems.Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screenedversion is suitable for switching signals up to 50MHz. Larger matrices may be constructedby Daisy Chaining the common signals from multiple PXI modules.
-
40-512-022 -
Pickering Interfaces Ltd.
The 40-510 series of matrix modules feature a wide range of selectable switchingconfigurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signalrouting in ATE and data acquisition systems.Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screenedversion is suitable for switching signals up to 50MHz. Larger matrices may be constructedby Daisy Chaining the common signals from multiple PXI modules.
-
40-513-022 -
Pickering Interfaces Ltd.
The 40-510 series of matrix modules feature a wide range of selectable switchingconfigurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signalrouting in ATE and data acquisition systems.Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screenedversion is suitable for switching signals up to 50MHz. Larger matrices may be constructedby Daisy Chaining the common signals from multiple PXI modules.
-
40-513-021-S -
Pickering Interfaces Ltd.
The 40-510 series of matrix modules feature a wide range of selectable switching configurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signal routing in ATE and data acquisition systems. Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching signals up to 50MHz. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules.
-
40-513-021 -
Pickering Interfaces Ltd.
The 40-510 series of matrix modules feature a wide range of selectable switching configurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signal routing in ATE and data acquisition systems. Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching signals up to 50MHz. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules.
-
40-510-021-S -
Pickering Interfaces Ltd.
The 40-510 series of matrix modules feature a wide range of selectable switching configurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signal routing in ATE and data acquisition systems. Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching signals up to 50MHz. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules.
-
40-510-021 -
Pickering Interfaces Ltd.
The 40-510 series of matrix modules feature a wide range of selectable switching configurations (12x4,dual 12x4,12x8 and 24x4). Typical applications include signal routing in ATE and data acquisition systems. Available reed relay formats are 1-pole, 2-pole and 1-Pole screened. The screened version is suitable for switching signals up to 50MHz. Larger matrices may be constructed by Daisy Chaining the common signals from multiple PXI modules.
-
60-310-102 -
Pickering Interfaces Ltd.
The 60-310 is a 2-pole Matrix Module available in 300x2, 200x2 and 100x2 formats. It is capable of cold switching 1000VDC and has a maximum carry current of 1A. It is designed for high voltage applications including circuit board isolation testing, relay testing, semiconductor breakdown monitoring and cable harness insulation testing. The 60-310 is designed in accordance with the LXI Standard 1.4 and is supplied in a 2U high, full rack width case with 500mm depth.
-
40-550-002 -
Pickering Interfaces Ltd.
Connections are made via a front panel 37-way D-Type male connector or two 20-way GMCT male connectors. Used for switching inductive/capacitive loads up to 5A at 250VAC. Power matrix modules are intended for switching heavy AC or DC loads or for slaving up to large external relays, contactors and solenoids. Used for applications requiring switching of either mains voltage or direct current. These modules are fitted with electro-mechanical power relays, gold-flash over silver alloy. A spare relay is built onto the circuit board to facilitate easy maintenance with minimum downtime.
-
Pickering Interfaces Ltd.
The PXI fault/signal insertion matrix design is based on Pickering's proven BRIC architecture that allows the matrix size required for an application to be selected from the many versions available.
-
40-545-001 -
Pickering Interfaces Ltd.
The 40-545 series of modules are high density power switching matrices. Typicalapplications include power routing in Functional ATE systems, specifically automotiveelectronics, for example testing of Engine Management Units.
-
34933A -
Keysight Technologies
The Keysight 34933A module for the 34980A Multifunction Switch/Measure Unit gives you the most flexible connection path between your device under test and your test equipment, allowing different instruments to be connected to multiple points on your device under test at the same time. Dual 4x8, 8x8, or 4x16 2-wire configurations 64 2-wire or 128 1-wire cross-points High-speed reed relays Connections to the internal DMM Expandable via four 2-wire analog buses Relay counter ±150 V peak, .5 A switch, 1.5 A carry current
-
34932A -
Keysight Technologies
The Keysight 34932A module for the 34980A Multifunction Switch/Measure Unit gives you the most flexible connection path between your device under test and your test equipment, allowing different instruments to be connected to multiple points on your device under test at the same time. Dual 4x16, 8x16, or 4x32 configurations 128 2-wire cross-points 300 V, 1 A switch; 2 A carry current Connections to the internal DMM Latching armature relays, with relay counter Expandable via four 2-wire analog buses