Current Calibrators
An accurate current units of measure to facilitate comparison to and adjustment of instruments.
-
Product
30 Amps, 50 MHz BW Current Probe - AC/DC , 50 Amp Peak Pulse
CP030
-
Teledyne LeCroy current probes are available in a variety of models for a wide range of applications. The full range of Teledyne LeCroy current probes includes models with bandwidths up to 100 MHz, peak currents up to 700 A and sensitivities to 1 mA/div. Teledyne LeCroy current probes are often used in applications such as the design and test of switching power supplies, motor drives, electric vehicles, and uninterruptible power supplies.
-
Product
Precision Voltage to Current Converter
64-VCC
-
The 64-VCC precisely converts voltage to current. The unit can be placed in-line with a data acquisition system to achieve outstanding conversion accuracy for precise movements in valves or motors. The unit includes a unique current feedback measurement output to precisely monitor actual current in critical applications.
-
Product
High Speed-Large Current DC Electronic Load (CC/CV/CR/CP)
PLZ-4WL Series
-
While the PLZ-4WL series succeeds to the superior operability of our conventional model of the PLZ-4W series, the PLZ-4WL series realizes the high speed rise and fall time (slew rate of 50A/µs.) in the range of low voltage with large current. The PLZ-4WL offers six operation modes, and equips with various features such as sequence operation, switching operation, soft-start function, and time and voltage measurement. The PLZ-4WL applies not only for the conventional load test of the CPU power supply, but also it can be applied to even faster current response test. In addition, the PLZ-4WL is a space-saving design (about 50% less volume of the conventional model) that can save the facility space of the testing site, and it can be applied for the single cell testing of the large scale rechargeable battery.
-
Product
DC Precision Current Sources
-
DC Precision Current Sources provides precise and very stable output currents from 3 A to 10,000 A. The 6623A-PCS Series provides the best uncertainties of any DC high current sources (i.e. < 5 ppm of precision and stability at 1000A). In addition this Series is modular and initial output currents can be expanded at any time.
-
Product
Dry Block And Bath Calibrators
-
These units are used to calibrate sensors such as thermistors, thermocouples and RTD's. Different temperature ranges, accuracies and stabilities to cover most sensor specifications.
-
Product
Pt100 Temperature Transmitter PC Programmable With Push Button Calibration
SEM1605/P -
-
SEM1605/P - Pt100 Temperature Transmitter PC Programmable With Push Button Calibration
-
Product
Rugged Igniter Tester With Current Monitor And Single Connection For Measurement And Charging
4314 KVM
-
The Valhalla Scientific Model 4314 KVM Digital Igniter Tester is designed to provide extremely safe and reliable resistance testing of explosive or volatile devices. Proven uses include fuses, squibs, igniters, explosive bolts, automobile airbag initiators and many others.
-
Product
AC Current Clamp Adapter
LAD-800
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
●Selectable CT ratio 10:1 and 100:1.●φ80mm CT window, possible to measure from leakage to big current up to 1000A.
-
Product
Portable Humidity Calibration Case
Hygro-box
-
Hygro-box is a easy-to-use, portable, IP68 humidity calibration case, suitable for outdoor or moving application.
-
Product
Current Transformers
-
The Institute of Electrical and Electronic Engineers defines a current transformer (IEEE Std C57.13) as “a transformer intended to reproduce in its secondary circuit, in a definite and known proportion, the current of its primary circuit with the phase relations substantially preserved”. Its primary winding is connected in series with the conductor carrying the current to be measured or to be controlled and its secondary winding is connected to the measuring, protection or control devices. Osborne designs and manufactures current transformers which are used for instrumentation applications, others which are used for power system synchronizing applications and others which are used in protection circuit application. They have been designed to meet specified current ratios, burden impedance and transformation errors.
-
Product
Clamp type AC Current Sensor/for Low Leakage Current Measurements(ZCT Series)
ZCT-340L
-
MULTI MEASURING INSTRUMENTS Co., Ltd.
*Best sensor for low leakage current measurements of less than 1mA.*Suitable for low current measurements of terminal feeder.*High sensitivity and least affection from external magnetic field.
-
Product
Monitor Calibrator
hueyPRO
-
It's all about the color. Color in your photos, color in your designs, color online and more importantly, color on your display. World's first built-in ambient light sensor enables consistency never seen before in any lighting condition.
-
Product
8 SE Or 4 Diff. Input Channels, 4 Analog Current Output Channels, PCI Express
APCIE-3121-8-4C
-
Input range:?± 10 V, 0-10 V software programmable0-5 V, ± 5 V, 0-2 V, ± 2 V, 0-1 V, ± 1 V (gain)0-20 mA (option) ? software-programmable amplifier:PGA x1, x2, x5, x10 ? Conversion triggered through software,scan, timer, external event ? Onboard FIFO buffering for 256 analog values ? Data exchange through 16-bit I/Oor 32-bit memory (PCI DMA) ? Sequence RAM ? Overvoltage protection ? input filter: 160 kHz
-
Product
Earth Leakage Breaker And Residual Current Device
IGR Series
-
IGR Leakage Current Analyzer is invented as the world first, and also can measure Insulation Resistance (MO) without power cut-off. This patented instrument can analyze leakage current, and display Igr(resistive), Igc(capacitive), and Io(vector sum), Ground Insulation Resistance, and the phase angle between voltage and current. (IGR ELB) - Operates due to Igr. - Properly-operating in spite of IGC in digital era. ( Not tripping on UPS load and Harmonics and noise area) - Possible to go down Igr for safety of people and animals. - Possible to manufacture high sensitive ELB. - Possible to prevent fire from electric leakage current.
-
Product
Bench Power Supply, Calibrated, Adjustable, 1 Output, 0 V, 30 V, 0 A, 5 A
72-2690 CAL
-
The 72-2690 CAL from Tenma is a single channel adjustable bench top power supply. It is a digitally controlled industrial grade power supply with load for a long time. This compact design power supply has complete digital control, intelligent temperature controlled fan, low noise and low ripple. It also features knob lock function to avoid improper operation. This power supply has load regulation ≤0.01% +2mV (voltage), ≤0.1% +5mA (current) and line regulation of ≤0.01% +3mV (voltage), ≤0.1% +3mA (current). The setting accuracy (25°C ±5°C) is ≤0.5% +20mV (voltage), ≤0.5% +10mA (current).
-
Product
Calibrated Solar Reference Cell
-
To insure repeatable testing on any solar simulator, OAI offers 2cm x 2cm calibrated reference cells. Standard reference cell calibration cycles can be set up by OAI''s calibration laboratory to insure that your reference cell maintains certification.
-
Product
Calibration / AVP Service
-
Comware Technical Services, Inc.
Regular calibrations / AVPs will help ensure the measurement integrity of your system. We supply the calibration equipment or you can provide us with your own in-house equipment.
-
Product
Hart Multifunction Calibrator
Model 26 / 26 H
-
Kusam Electrical Industries Limited
The multi-functional field process calibrator with high accuracy and stability, which can provide powerful measurement or output functions & other special functions to meet all the calibration work for field process control.
-
Product
Infrared Thermometer Calibration
-
Nagman Instruments & Electronics Pvt. Ltd
Nagman’s Infrared thermometers Calibration Instrument can be used for hassle free temperature measurements as they work on non- contact principles. You can stay at a safe distance from the temperature source and still find accurate readings by pointing IR thermometer at the source. These also have a digital display of the temperature readings and hence, any and all manual errors can be avoided.
-
Product
AC Current Probe 20 mV/A, 300A, 9.2 Hz LF Bandwidth, 30MHz HF Bandwidth, 1m cable
T3RC0300-UM
-
AC Current Probe 20 mV/A, 300A, 9.2 Hz LF Bandwidth, 30MHz HF Bandwidth, 1m cable.
-
Product
AC Current Probe 2 mV/A, 3,000A, 3 Hz LF Bandwidth, 23MHz HF Bandwidth, 4m cable, 200mm coil
T3RC3000-HF
-
AC Current Probe 2 mV/A, 3,000A, 3 Hz LF Bandwidth, 23MHz HF Bandwidth, 4m cable, 200mm coil.
-
Product
Current Seasoning Equipment For Vacuum Interrupter
-
our company is counted among the topmost manufacturers and exporters of Current Seasoning Equipment for Vacuum Interrupter. We follow all the guidelines and standards of industry while manufacturing this equipment using best grade raw materials. Available in different models, this Vacuum Interrupter Current Seasoning Equipment is offered to clients at competitive price.
-
Product
Standard Voltage 9 Pin D-Type Cables - Calibration Cables for Pickering Products
-
The cable assemblies below are suitable for use with Pickering precision resistor cards and modules that utilize 9-pin D-type calibration port connector.
-
Product
Wet Leakage Current Test
-
King Design Industrial Co., Ltd.
The outdoor solar module will endure the erosion of rain, fog, snow and sandstorm. To make sure that solar module will not wet leakage current accident and tolerate huge load pressure in such harsh conditions, we adopt wet leakage current to simulate the above weather conditions.
-
Product
Device Current Waveform Analyzer, 1 GSa/s, 14/16-bit, 4 Channel
CX3324A
-
The CX3324A is a 4-channel model for engineers and researchers who need more than two channels for current waveform measurements at one time. Using a passive prove interface (CX1151A) with a current sensor (CX1101A, CX1102A, CX1103A) enables power measurements. The bandwidth and the memory depth per channel are option and can be selected from 50 MHz, 100 MHz and 200 MHz, and 16 Mpts, 64 Mpts and 256 Mpts, respectively. Upgrade products for both bandwidth and memory depth options are also available for customers who need more performance after purchasing the product. 8-channel digital channel (CX1152A) can be used with this 4-channel model so that you have more flexibility of triggering.
-
Product
Current Sensing Resistors, Thick Film Type
-
Panasonic Industrial Devices Sales Company of America
An AEC-Q200 Compliant SeriesPanasonic components specified as AEC-Q200 Compliant are consistently designed into automotive systems. However, today’s Design Engineers are specifying AEC-Q200 components to meet the high-quality standards of devices beyond automotive applications.
-
Product
Current Pulsers and Laser Diode Drivers (Pulsed Current)
-
These instruments generate current pulses whose amplitude is largely independent of the load voltage. This makes them ideal for pulsing device whose voltage may vary with time (for instance, the voltage drop of laser diodes may vary with temperature, or explosive squibs which change impedance during ignition). This voltage independence is a trade-off with speed. If faster rise times are required, consider using pulsed voltage instruments instead.
-
Product
Current Transformer Tester
CTT
-
The CTT is designed to test the current transformer ratio, Phase shift, Polarity, Excitation, Saturation, Winding resistance and Insulation resistance using the voltage method in compliance with ANSI/IEEE C57.13.1 and IEC 60044-1 standards, where voltage is applied to the secondary X terminals of the current transformer.
-
Product
Sound Level Meters and Calibration
-
PeakTech Prüf- und Messtechnik GmbH
This digital sound level meter is designed for noise projects, quality control and all kinds of measurements of ambient sound, as well as for sound measurement in factories, schools, offices, in traffic , Household and much more used.
-
Product
Current Tester
MIG0624
-
The MIG0624 current tester is designed to test surge protection devices for low voltage applications (<1000 V). MIG0624 is a current generator delivering a 8/20 µs impulse up to 24kA. The exact waveform delivered is a function of the surge generator and the impedance to which the surge is applied.