Showing results: 1201 - 1215 of 2906 items found.
-
P200 -
FLC Electronics Inc
The P200 is a general purpose linear amplifier having a fixed amplification of 10 times and capable of bipolar high voltage output of ±100V. Any functiongenerator or arbitrary waveform generatoror any othe signal source with amplitude up to ±10 V can be used as an input device.
-
P100 -
FLC Electronics Inc
The P100 is a general purpose linear amplifier having a fixed amplification of 10 times and capable of bipolar high voltage output of ±50V. Any functiongenerator or arbitrary waveform generatoror any othe signal source with amplitude up to ±10 V can be used as an input device.
-
Process Instruments Inc.
Optical pyrometers can be calibrated from 800 to 2300C using NIST certified ribbon filament lamps and temperatures up to 3500C using a graphite arc furnace. Infrared thermometers can be calibrated from -30C to 2300C utilizing state-of-the-art blackbody sources and transfer standards.
-
HD2402 -
Delta OHM S.r.L.
HD2402 is a portable photo-radiometer data logger for the measurement of noncoherent optical radiation in accordance with European Directive 2006/25/EC and the Legislative Decree No 81. The instrument consists of a series of sensors to cover different portions of the spectrum and a small laser which is used to indicate the analyzed source.
-
Focus Microwaves
Minimum Noise Figure (Fmin): This is the smallest Noise Figure that the device can reach at a given frequency and bias, if it is optimally matched at the source.Equivalent Noise Resistance (Rn): This is a number with the dimension Ohm that indicates how fast the Noise Figure increases when we mismatch the input (source).
-
Dayton T. Brown, Inc.
Every object affects or interprets light differently, so appropriate and accurate measurements are needed in order to determine how much light is being produced by a source or cast upon an object. This can be measured with respect to power requirements, as well as how the human eye interprets that light.
-
EE-120A-3 -
EMSYST Ltd
The Current Source is able to generate three-phase currents, synchronized with the service voltage, with unprecedented stability and measurement accuracy. The amplitude and phase-shift of each current is individually adjustable. The values of voltage, current, power, power factor, phase shift, THD and frequency are indicated on the LCD display.
-
DDR3 -
Integrated Geo Instruments & Services Private Limited
The DDR 3 Resistivity Meter is a specialized version of IGIS Resistivity meters designed for use in Resistivity surveys up to about 200m depth. It utilizes rechargeable batteries as power source to energize the ground thus eliminating the necessity of using the relatively expensive dry cells.
-
STM-1 -
ECO-TECH
Tapping Machine Type STM-1 is intended for measurements of acoustic insulation of ceiling in buildings. The unit fulfils Annex A of ISO 140-6/7. These parts of the standard require a tapping machine as a sound source for impact noise measurements. Type STM-1 is available with an optional remote control.
-
KT-8301B -
KILTER ELECTRONIC CO.,LTD
3 3/4 digits display, max. reading of 3999Auto range and manual operationCapacitance, Inductance, Frequency, Continuity, Diode, Transistor TestData Hold function, Auto power offDuty cycle measurement: 0.1%~99.9%Power source: RO3 UM4 AA SIZE 1.5Vx2
-
KT-8302B -
KILTER ELECTRONIC CO.,LTD
3 3/4 digits display, max. reading of 3999Auto range and manual operationCapacitance,, Frequency, Continuity, Diode, Transistor TestData Hold function, Auto power offDuty cycle measurement: 0.1%~99.9%Power source: R03 UM 4 AA SIZE 1.5Vx2
-
Insight -
BAE Systems Inc.
The Defense Advanced Research Projects Agency (DARPA) Insight program aims to develop an adaptable, integrated human-machine Exploitation and Resource Management (E&RM) System to make it easier for intelligence analysts to derive actionable intelligence from a growing number of sensors and data sources.
-
80609010 -
6TL Engineering
The differential active probe helps to carry weak HF signals far away with the minimum disturbance of the original source. The module accepts discrete wiring or direct spring loaded test probe solder. In any case, the input signal wires might be as short as possible.
-
1121A -
Boonton Electronics
The Model 1121A audio analyzer provides fast, accurate measurements including frequency, AC or DC level, distortion, SINAD and signal-to-noise ratio. It also includes an audio source providing accurate low distortion signals over wide frequencies and level ranges.
-
EPU352 -
eDAQ Pty Ltd.
A compact signal conditioner for monitoring low current, two-electrode (anode and cathode) amperometric sensors. By setting the polarization voltage to zero it can also be used as a zero resistance ammeter (ZRA).Electrical isolation ensures that readings are not influenced by nearby current sources such as conductivity, or voltammetric electrodes.