Infrared Calibrators
controlled sources of thermal radiation, used to calibrate infrared radiation devices.
-
product
Transformer Calibrator
HTQA-C / 345
Wuhan Huatian Electric Power Automation Co., Ltd.
A device used to change the current.
-
product
Deskew Calibration Source for CP030, CP030A, CP031, CP031A, AP015, CP150, CP500
DCS025
The DCS025 Deskew Calibration Source generates time-aligned voltage and current pulses for precise deskew of voltage and current probes.This is critical for measurements in which small propagation delay differences between probes can have a large impact on a calculated measurement, e.g., instantaneous power semiconductor device loss measurements.
-
product
High Precision Angular Position, Calibration and Geometry Inspection
GeoOrdinate
Rotary Precision Instruments UK Ltd
Ultra precise rotary tables intended for fine inspection, metrology and test applications.The GeoOrdinate has been designed specifically for the inspection of large and heavy components and is fully compatible with any shop floor environment whilst maintaining world class accuracies more commonly seen in the standards laboratory.
-
product
3-in-1 OSL Mechanical Calibration Kit, DC To 50 GHz, 2.4 Mm (m)
85564A
The 85564A 3-in-1 mechanical calibration standard combines an open, short and load standard in a compact unit. The product is small, easy to handle, and lightweight. All standards in the 85564A are male 2.4 mm.
-
product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, 4.3-10, 2 Port
85094D
The Keysight 85094D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
product
Time to Amplitude Converters and Calibrator
A Time-to-Amplitude Converter (TAC) can achieve exceptional precision by using an analog technique to convert small time intervals to pulse amplitudes. When a timing application demands picosecond precision, a time-to-amplitude converter is a prime candidate. A time-to-amplitude converter is a productive solution for measurements less than 10 μs when time resolutions from 10 ps to 50 ns are required.
-
product
Infrared, Near Infrared and Raman Spectroscopy
From the very compact FTIR spectrometer to the world’s highest resolution: Bruker offers the industry's largest selection for demanding routine and High End FTIR research application including the new and unique verTera cw THz functionality.Process monitoring with FTIR / FT-NIR process spectrometers.A complete line of Near Infrared Spectrometers to fit all your needs, including Process Monitoring.FTIR Microscopy and Raman Microscopy and Spectral Imaging for high sensitivity at high spatial resolution.High spectral resolution, high performance Raman and FT-Raman spectrometers for advanced routine solutions.
-
product
Calibration
We also help to fulfil the recommended calibration cycles of the other measurement instruments within your test system. In case you can not go without the whole system we will find another solution like a change or loan of single devices.We also offer whole test system calibrations on-site as part of our preventive maintenance concept.
-
product
Calibration Standards, Calibration Services
ISO 17015 traceable calibrated reference lamps, detectors and reflectors for the calibration and adjustment of sensors and measurement devices for light, optical radiation and light reflection. We offer as well many ISO 17025 calibration services.
-
product
Calibration
EMC Test Antennas
There are some changes in the calibration standard ANSI C63.4 concerning the calibration procedures of hybrid antennas, also the newly issued standard - CISPR 16-1-6 dealing with EMC antenna calibration is covered by our services. You are very welcome to consult Seibersdorf Laboratories calibration experts for the recommended calibration procedures of the most common radiated emission test standards.
-
product
Infrared, Near Infrared and Raman Spectroscopy
rom the very compact FTIR spectrometer to the world’s highest resolution: Bruker offers the industry's largest selection for demanding routine and High End FTIR research application including the new and unique verTera cw THz functionality.Process monitoring with FTIR / FT-NIR process spectrometers.A complete line of Near Infrared Spectrometers to fit all your needs, including Process Monitoring.FTIR Microscopy and Raman Microscopy and Spectral Imaging for high sensitivity at high spatial resolution.High spectral resolution, high performance Raman and FT-Raman spectrometers for advanced routine solutions.FTIR Gas Analyzers for the fully automated and high precision real-time monitoring of gas compoundsImaging Remote Sensing systems for analysis of gases, liquids and solids.CryoSAS semiconductor material quality control for photovoltaic and electronics industry.OPUS, the "all-in-one" IR and Raman spectroscopy software consists of a suite of software packages that cover both standard and specialized applications.ONET, software for the setup, administration and control of large FT-NIR spectrometer networks.
-
product
Pressure Calibrator
HPC50
AMETEK Sensors, Test & Calibration
The HPC50 handheld pressure calibrator is an intrinsically safe, dual pressure calibrator with options to add an additional two external pressure or temperature modules. The HPC50 pressure calibrator combines the features you love from the HPC40 with improvements like, better battery life an improved display, an extra external module connection, and of course intrinsic safety.
-
product
RF Calibration Kit
SMK-3000
The SMK calibration kits are precision, high power calibration standards that are used to calibrate RF radios, wattmeters, directional couplers and other high-power RF test equipment in the field or metrology lab. Unlike other calibration solutions, the SMK-3000 calibration kits reduce the cost of ownership and provide a much faster time-to-calibration with lab precision and accuracy you’ve come to expect from Bird.
-
product
Bench Digital Multimeter, Calibrated, 1 kV, 10 A, 3.8 Digit
72-1015 CAL
The 72-1015 CAL from Tenma is a digital bench type true RMS multimeter. It has auto and manual range options with maximum reading of 5999 counts and 3-5/6 digits which has a unique outlook design. In addition to all the conventional features including DC/AC voltage, current, resistance, diode, continuity test, diode test capacitance, temperature, transistor, max/min, there is a data hold, low battery display, sleep mode, RS232C serial port for easy connection with computer to realize macro recording, monitoring and capture of transient dynamic data, displaying change of waveform during the measurement, providing data and evidence to engineering technicians for scientific research. This meter complies with the standards IEC61010, pollution degree 2, overvoltage category (CAT I 1000V, CAT II 600V) double insulation and CE marked.
-
product
Mobile Calibration Services
Your One-Stop Calibration provider for calibration and instrument services is now even better with our fleet of mobile labs. Trescal is bringing our high-quality precision calibration on the road to make calibrating your equipment as easy and convenient as possible. Our qualified technicians are available across the U.S. to provide the on-site mobile calibration services you need.
-
product
Acoustic Emission Calibrator
AE calibrator is similar to a simple signal generator, it can generate a variety of controlled waveform signal, different types, different amplitude and different frequency. It can help users calibrate acoustic emission detection equipment before acoustic emission detection.
-
product
Calibrator for Vibration Transducers
HD2060
Hand-held calibrator for vibration chains with frequency 15.915 Hz and levels 1 m/s² and 0.1 g, and frequency 159.155 Hz and levels 10 m/s² and 1 g. With LCD display.
-
product
Infrared Thermometer
64 MAX
Fluke 64 MAX IR Thermometer features Auto Capture allowing technicians to set time and intervals to record up to 99 data points unattended so it can capture elusive temperature events. The thermometer can be mounted on a standard tripod using a tripod mount accessory for unattended measurements. The 64 MAX displays minimum, maximum, or average temperature, or the difference between two measurements, and features Hi and Lo alarms for rapid display of measurements outside set limits.
-
product
Velocity Calibration
Trescal provides full Velocity Calibration services that are accredited and/or certified in accordance with ISO/IEC 17025. Velocity Calibration services can be delivered at your site or at our lab. Accreditations for our velocity calibration service guarantees calibration results are traceable to the International Systems of units (SI) through NIST or NRC.
-
product
CALIBRATOR Multi Function Calibrator
MC140
The Multifunction Calibrator MC140 functions as a Voltage Calibrator, Current Calibrator, Power Calibrator, Resistance Calibrator, Capacitance Calibrator and a Thermocouple Calibrator.? Having very low uncertainties, it is ideal as a standard of these electric quantities in calibration laboratories.
-
product
Calibrate Camera RAW Image Files
SpyderCUBE™
Accelerate RAW processing by taking one reference shot under any light condition to set the white balance, exposure, black level and brightness right from the start for your entire series of photos.
-
product
Infrared Pyrometer with Laser Sighting
thermoMETER CTlaser
Pyrometers of the thermoMETER CTLaser series are used for precise, industrial measurements. Using two laser beams, the measurement spot is marked which ensures a precise temperature measurement. thermoMETER CTLaser temperature sensors are used in numerous applications. From extremely low temperatures (-50°C) to the highest temperatures (3000°C), these IR pyrometers measure precisely and reliably.
-
product
Calibration
Calibration of a measuring tool is an operation that allows an assessment of the accuracy of the measurement, and the adjustment of the measuring tool so that it is more accurate. In scientific formulation, calibration makes it possible to evaluate the measurement error.
-
product
Voltage Calibrators
Practical Instrument Electronics, Inc.
PIE has a voltage calibrator to fit your needs from the PIE 235 voltage and pH simulator to the advanced troubleshooting capabilities of the PIE 532 milliamp and voltage calibrator. The PIE 532 includes our patented Loop Diagnostic Technology! All the voltage/milliamp calibrators have fuse-less protection, rugged design and long battery life. With the PIE 535, source 4 to 20 milliamps or 10 to 50 milliamps into loop instruments and drive final control elements such as valves and actuators with up to 42 volts.
-
product
Current & Voltage Sources for Calibration of Measuring Systems and Sensors
ChenYang Technologies GmbH & Co. KG
*DC/AC Current: 0-60A *DC/AC voltage: 0-1000V frequency 50Hz, 60Hz, 400Hz, 1kHz
-
product
RF Electronic Calibration Module (ECal), DC/300 KHz To 9 GHz, Type-N, 2 Port
85092D
The Keysight 85092D RF electronic calibration (ECal) module makes calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.
-
product
Calibration Sources
Up to an absolute accuracy of 60 MHz standard HighFinesse Wavelength Meters feature auto-calibration by integrated calibration sources. This way highest accuracy and stability of measurements with our wavemeters is guaranteed.
-
product
Calibration & Demag.
Model 5655
The model 5655 is a capacitive-discharge magnetizer / demagnetizer / calibration unit.
-
product
Transducer Calibration
When it comes to finding the perfect transducer calibration system, look no further than MB Dynamics. Our Calibration Systems offer an extensive range, from the Win475-Basic, the trusted calibration solution for the United States Air Force; to the first of its kind Win475-TS, which measures a transducer’s transverse sensitivity. No matter what your needs, you’ll find the calibration equipment that works for you.





























