Infrared Calibrators
controlled sources of thermal radiation, used to calibrate infrared radiation devices.
-
Product
WAVEPULSER-40IX + WAVEPULSER-SI-STUDIO-NRZ + Adaptors and Calibration Kit
WAVEPULSER-40iX-BUNDLE
-
High-speed Interconnect Analyzer, 4-port, S-par @40 GHz, <1 mm Res., 4 phase matched cables, bundle.
-
Product
Bench Power Supply, Calibrated w/Data, Adjustable, 1 Output, 0 V, 30 V, 0 A, 5 A
72-2690 CAL D
-
The 72-2690 CAL D from Tenma is a single channel adjustable bench top power supply. It is a digitally controlled industrial grade power supply with load for a long time. This compact design power supply has complete digital control, intelligent temperature controlled fan, low noise and low ripple. It also features knob lock function to avoid improper operation. This power supply has load regulation ≤0.01% +2mV (voltage), ≤0.1% +5mA (current) and line regulation of ≤0.01% +3mV (voltage), ≤0.1% +3mA (current). The setting accuracy (25°C ±5°C) is ≤0.5% +20mV (voltage), ≤0.5% +10mA (current).
-
Product
MCB Thermal Trip Calibration Test Bench (IEC 60898 Cl 9.10.1.2, Annex I.1, IS)
-
The test system is designed and customized to carry out 2.55*Intest as per Table 7 (test c) of IEC 60898 (also mentioned for routine testing of MCBs. The test is done at dc current to exactly analyze and correct the bimetallic properties of the MCB as far as thermal tripping is concerned. The unit comes with a pneumatically operated test fixture with in-built dc stepper motor that is controlled by a micro controller / PC to calibrate the breaker into a narrow tripping band programmed by the user.
-
Product
Calibration Executive Software
CalEasy Series
-
CalEasy is a full-featured, Calibration Executive software package that supports the verification and calibration of Marvin Test Solutions instruments. The software is intended for use by users that prefer to perform in-house calibration and verification for their Marvin Test Solutions instruments. By calibrating or verifying the instrument in-house, the time and cost associated with returning an instrument to Marvin Test Solutions for calibration service can be eliminated or reduced. CalEasy is also used internally by Marvin Test Solutions production to perform initial calibration and to recalibrate the instrument when received for service. This ensures that user and factory based calibration performance is similar. Depending on the specific instrument, standards instrumentation supported for calibration / verification includes a DMM, and a frequency standards module. Some modules require the use of matrix switch card.
-
Product
Optical & RF Test Equipment Repair and Calibration
-
Custom Calibration Solutions, LLC
We are the only commercial repair lab in the country capable of fixing major problems with optical test equipment including OSA's, Tunable Lasers, Attenuators and Optical Wavelength meters.
-
Product
Calibrated Leak Standards
-
LeakMaster is a leader in the industry when it comes to the manufacturing of calibrated leak standards (calibrated leak orifices). Each leak standard is meticulously manufactured to a specific leak or flow rate at a predetermined pressure. The purpose of each leak standard is to teach, or calibrate a leak test program, and allow the leak test instrument to memorize the characteristics of a leaking part. These leaks are also introduced into production parts to simulate a “leaking or failed” part condition. LeakMaster supplies a calibrated leak standard with every leak test instrument, and provides recertification services for all of their leak standards
-
Product
Conformance Calibration Standard Test Card for GS1-DataBar Symbol Verifiers
AI-CCS-DATABAR
-
This test card is ideal for testing verifiers, scanners, and other GS1-DataBar barcode reading equipment. It also can serve as an excellent training aid to ensure new operators are using the proper methodology and are proven competent in the use of verifiers.
-
Product
Gauges & Calibrators
-
Ralston Instruments' gauges and calibrators are born from decades of experience working with technicians, project managers and facilities teams responsible for maintaining metrology instruments.
-
Product
Sound Level Calibrator
511E
-
Accepted internationally 1 kHz represents the "0 dB" reference point of A, B, C Weighting and other filters utilized in acoustic measurement. The Pistonphone - a mechanical sound source - offers a slightly higher degree of accuracy at a substantial increase in cost. In addition, the 200 or 250 Hz operating frequency is mechanically limited and not suited for measurements of filtered inputs. The 0.2 dB accuracy is quickly lost in the 0.7 to 1.5 dB tolerances acceptable for weighting filters at frequencies around 250 Hz.
-
Product
Power and Energy Automated Calibration System
RS-933
-
The RS-933 Syntron Power and Energy Automated Calibration System calibrates a range of test equipment including; Energy Reference Standards, Digital Multimeters, Phase meters, Energy meters, Power meters, Revenue meters, Amp meters, Panel meters & Power Quality meters.
-
Product
Crossover Calibrator
CC-1
-
The purpose of this tool is to enable the installer to set the crossover frequency of an electronic crossover to the desired frequency, accurately and quickly. It can also be useful for matching gains on multiple amplifier competition type systems.
-
Product
Acoustic Emission Calibrator
-
AE calibrator is similar to a simple signal generator, it can generate a variety of controlled waveform signal, different types, different amplitude and different frequency. It can help users calibrate acoustic emission detection equipment before acoustic emission detection.
-
Product
Decade Box, Calibrated, Capacitance, 5, 100pF to 11111µF, 5 %
72-7265 CAL
-
The 72-7265 CAL from Tenma is a capacitance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set at any non polarized capacitor value from 100pF to 11,111µF in 100pF increments. The decade accuracy is ±5% capacitors used throughout at <1μF, 1KHz test frequency, ≥1μF, 100Hz test frequency. It has weight of 304g/0.69lb and dimension is 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Accredited Humidity Calibration Services
-
Thunder Scientific's calibration laboratory is accredited by NVLAP (National Voluntary Laboratory Accreditation Program), Certificate of Accreditation No. 200582-0 to ISO/IEC 17025 and ANSI/NCSL Z540-1 1994.
-
Product
Calibration and Verification Kits
-
Flann offers a wide range of calibration and verification kits to suit many applications and price points. Compatibility with the vast majority of current and legacy VNAs can be provided. Additionally full customisation of our kits is possible to suit your requirements.
-
Product
On-Site Calibration Services
-
Labsphere offers on-site spectral radiance calibration services for HELIOS and other uniform source systems.
-
Product
Shortwave Infrared Camera Core
Tau® SWIR
-
FLIR Tau® SWIR provides outstanding short-wave infrared image quality and performance over a wide range of imaging and light level conditions. It is the ideal OEM SWIR imaging module for applications like hyperspectral instrumentation, silicon inspection, electro-optical payloads, art restoration, and portable imaging. The Tau SWIR camera incorporates the FLIR high resolution 640×512 ISC1202 Indium Gallium Arsenide (InGaAs) 15-micron pitch focal plane array (FPA) and includes several advanced camera controls features.
-
Product
Testwave Calibration
-
Testwave® LLC calibrates electronic, physical, & dimensional test equipment. Our Sparks facility includes a state-of-the-art temperature controlled calibration laboratory, which holds the temperature to within +/- 0.5°C. We send you recall notices before your equipment calibration expires, and if we don’t hear from you, we will call, to make sure you stay in compliance with your calibration requirements. Calibrations are performed at your facility, or at our Sparks Nevada laboratory.
-
Product
Decade Box, Calibrated W/Data, Resistance, 7, 1ohm to 11.11111Mohm, 1 %
72-7270 CAL D
-
The 72-7270 CAL D from Tenma is a resistance decade box. It is ideal for service, prototype and experimental use. This useful tool may be set resistance value from 1 to 11,111,110 ohm in one ohm increments. The decade accuracy is ±1% resistors used throughout. It has weight of 320g/0.70lb and dimension 14.7cm × 11.7cm × 5.5cm (5.79" × 4.61" × 2.16"). It is typically used in general applications, troubleshooting, maintenance, education and vocational training, production line testing, radio and TV services, working standards, research design & develop, physics laboratory work.
-
Product
Infrared Moisture Analyzer
LD-LIMA-A10
-
Infrared Moisture AnalyzerLD-LIMA-A10is an online, fast, continuous measurement and non-contact measurement device with measurement distance range of 20 to 40 cm. It provides automated control and 4 to 20 mA current signal. This IR Moisture Analyzer emits different wavelengths of infrared light (4, 6, 8, 10 beam) to calculate the moisture content of the measured object. Designed with long-life high-speed brushless motor, imported high response infrared sensors, information processing chip FPGA + DSP + ARM9 combination, to attain real time data, improved stability and precision.
-
Product
Conformance Calibration Standard Test Card for UPC/EAN Symbol Verifiers
AI-CCS-UPC/EAN-E Rev S
-
For those who prefer a traditional vertical format calibration test card, APPLIED IMAGE offers our new Conformance Calibration Standard Enhanced for UPC/EAN Bar Code Symbol Verifiers. The new standard complies with both the ANSI X3.182 and ISO 15416 standards and is ideal for testing of verifiers, scanners, and other UPC bar reading equipment as well as a tool for training new operators to assure proper “methodology' in the use of verifiers.
-
Product
Infrared Gas Detector
SMC 5100-28-IT
-
The SMC 5100-28-IT detector uses infrared technology, an accurate and stable gas detection method that is low maintenance and can operate in highly combustible and/or low oxygen environments.
-
Product
Calibrated Pocket Magnetometer
M 25
-
Instruments available in 8 different, Full Scale, Gauss Ranges.
-
Product
RF Calibration Accessories
-
Employing good connector practice when using an RF calibrator not only avoids measurement errors and minimizes connector repeatability uncertainties but also reduces risk of damage to connectors and equipment. The 96000CONN and 9600CONN connector kits include a range of adapters and torque wrenches intended for use with the 96000 Series RF Reference Sources (9600CONN for the 96040A and 96000CONN for the 96270).The 9600CONN connector kit includes one each of 50 Ω and 75 N-Type male-female adapter for use with the 96000 Series levelling head as a “connector saver” or “sacrificial connector” to avoid risk of damage when making connections to UUT/DUT instruments.
-
Product
Gas Calibrators and Zero Air Generators
-
Teledyne Advanced Pollution Instrumentation
All T Series instruments offer two front-panel USB ports, an advanced touch screen full color display, customizable user interface with predictive maintenance alerts, one-touch real-time graphing, and multiple language support. Teledyne API offers an extensive line of high quality gas calibrators and zero air generators to meet even the most demanding applications.
-
Product
Calibration & Demag.
Model 990A/990C
-
The Model 990 Series Magnetreaters® are highly accurate, pulse type, ringing demagnetizers (also called treaters) for the controlled stabilization of permanent magnets and permanent magnet assemblies. Regardless of line voltage stability, they provide a controlled output through continuous pulse amplitude regulation. Treating voltage is variable from 0 to 600 VDC. Additional energy can be added to the Model 990 Series by interconnecting a Model 992 Energy Booster. The energy level is increased from 18 to 36 watt-seconds. With this option, treating coils will produce higher demagnetizing fields and lower ringing frequencies, which can provide greater field penetration in some applications.
-
Product
Analyzer Calibration Extender
ACE
-
The ACE-1000A is a calibration solution that allows customers to self-calibrate their Kaelus PIM analyzers in the field. With successful calibration, ACE will extend your analyzer’s calibration while reducing downtime to less than one hour and increasing productivity by retaining instruments in the field.The Kaelus software guides the user through the calibration process from testing through payment including extending the calibration date of each Kaelus PIM Analyzer to 12 months, and printing the Certificate of Calibration certificate (CoC)
-
Product
Portable Multifunction Calibrator
M143
-
Clarke-Hess Communications Research
The M143 Multifunction calibrator is a cost saving solution for calibration of electric meters with up to 1000 V and 20 A. It offersa basic accuracy of 0.01% in DC voltage for calibration of 3 and 4 digit multimeters. The resistance function is covered byeight fix resistors in range from 10 to 100 M. The calibrator offers TC temperature sensor simulation. It can be deliveredoptionally as well with RTD temperature sensor simulator. Thanks to its small dimensions and low weight the unit can be usedeasily for field calibration work.
-
Product
Standard Voltage 9 Pin D-Type Cables - Calibration Cables for Pickering Products
-
The cable assemblies below are suitable for use with Pickering precision resistor cards and modules that utilize 9-pin D-type calibration port connector.
-
Product
RF Electronic Calibration Module (ECal), DC/300 KHz To 7.5 GHz, 7-16, 2 Port
85098D
Electronic Calibration Module
The Keysight 85098D RF electronic calibration (ECal) module makes the calibration of vector network analyzers fast, easy, and accurate. ECal is a precision, single-connection calibration technique for your vector network analyzer. Performing a full two-port calibration takes less than half the time and a number of connections using ECal versus mechanical calibration kits. Furthermore, the accuracy of the calibration is comparable between electronic and mechanical methods. Traditional mechanical calibrations require intensive operator interaction, which is prone to errors. With ECal, the operator simply connects the ECal module to the network analyzer and the software controls the rest.