- Virginia Panel Corporation
product
Receiver, 9025, 25 Module, EMI Gasket
310104431
The 25 Module Receiver is a rugged system devised to accommodate medium I/O. With high contact point availability, the 25 Module Receiver is suited for larger test and measurement systems. This 9025 offers a gasket for EMI applications.
-
product
ITA, 9075, 75 Module, Triple Tier, for EMI
410104449
ITA, 9075, 75 Module, Triple Tier, for EMI
-
product
ITA, G6x, 9 Module, Removable Backshell, Keying Feature
410104769
The adaptable G6x ITA integrates a wide variety of I/O options in various module configurations that allow engagement of up to 1,920 signal contacts. The G6x ITA has a removable backshell that also reduces electromagnetic interference.
-
product
PD Surveyor with RFI & EMI Diagnostics
PDS200
The Doble PDS200 is a combination survey tool that uses radio frequency interference and electromagnetic interference diagnostics to find signs of partial discharge.This hand-held instrument is an ideal tool for a condition based maintenance program, allowing you to quickly find insulation defects in motors, generators, transformers, cable terminations and additional substation components.
-
product
Power Supplies
CF-400B
The CF-series power supply is built with high-quality components for extra long life and maximum system performance along with heavy duty transformers supporting high-end systems. This fanless power supply has a built-in EMI filter for a true no-noise design. The aluminum chassis is built for maximum heat relief to keep the system cool. Combined with a great ventilated structure, you’ll never need a fan. This is a true silent structure that powers your system at 480 watts efficiency.
-
product
ITA, i2 MX, EMI, w/ 2 Hybrid Module Inserts
410130204
This model i2 MX includes 2 Hybrid Module inserts. Each module insert offers 8 Mini Power/Coax and 8 TriPaddle positions. Includes front protective cover.
-
product
Bench Power Supplies
Series ABC
Kepco¹s ABC bench power supply embodies the latest features: keyboard data entry, interactive digital display, integral GPIB support, software calibration, high frequency switch mode conversion, wide range input (85-264V a-c) and power factor correction. It meets the EN 61000-3-2 harmonic limits. A built-in EN 55022 Class B input EMI filter is provided. Integral External Trigger and RS 232 ports are now standard features.
-
product
EMI EMC test Solutions for Immunity
Scientific Mes-Technik Private Ltd
EMI EMC test Solutions for Immunity
-
product
FCC Part 15 Testing & Certification
FCC Part 15 is the section of Title 47 of the Code of Federal Regulations that sets limitations on the amount of electromagnetic interference allowed from digital and electronic devices. FCC Part 15 also covers technical specifications, administrative requirements and other conditions relating to the marketing of FCC Part 15 devices.
-
product
IsoVu Isolated Probes
The IsoVu Measurement Systems can make nearly impossible measurements – like high-side Vgs- a reality, providing today’s power engineer with measurement insights not available in other power systems and instruments. When performing near-impossible measurements, especially in those involving Gallium Nitride (GaN) and Silicon Carbide (SiC), it can be extremely time consuming and cumbersome. IsoVu eliminates those concerns: IsoVu probes offer better common mode rejection and higher bandwidth for high EMI environments and on power FETs like SiC and GaN.
-
product
EMI and EMC Test System
EMI receiver system. It is a main test system for EMI (Electro Magnetic Interference) testing. The EMI-9KB is produced by the full closure structure and strong electro-conductibility material, which has high shielding effect. Due to the new technology for the EMI Test System, it solved the instrument self-EMI problem.
-
product
EMC Testing Inductors
Electromagnetic Compatibility (EMC) testing is a somewhat unique discipline within the world of electrical product development and analysis. Electromagnetic Compatibility (EMC) testing is primarily concerned with understanding and mitigating the affects of Electromagnetic Interference (EMI).
-
product
VME Bus Repeater
VME-5532L
Easily link your VMEbus systems via fiber-optic cable, with total electrical isolation, no EMI generation and high-noise immunity.
-
product
Real Time Spectrum Analyzers
RSA600 Series
Visualize and characterize your device or component with the precise and accurate RSA603A and RSA607A USB Spectrum Analyzers, packed with features to aid in wireless integration, EMI, and IoT projects.
-
product
Emissions Test System
PC-114
Perform Radiated & Conducted EMI pre-compliance testing at your facility up to 1 GHz. Com-Power PC-114 EMI emissions test system is a ideal solution performing pre-compliance EMC testing from 9 kHz - 1 GHz.. It has essential equipment needed for radiated and conducted EMI emissions measurements. The system includes a spectrum analyzer, antennas, near field probes, a preamplifier, LISN and a non conductive antenna tripod. Pre-compliance testing in EMC is a commonly used term not easy to defin...show more -
product
EMI Test Receiver
ESW
With its outstanding RF characteristics, high dynamic range and measurement accuracy, the R&S®ESW is the best choice for fast and reliable certification measurements. It meets the most stringent requirements in line with CISPR, EN, MIL‑STD-461, DO‑160 and FCC. The R&S®ESW captures and weights disturbance spectra very fast with its FFT based time domain scan. The real-time spectrum analysis with spectrogram function permits detailed analysis of even the shortest disturbance signals. MultiView mode delivers a simultaneous display of results from multiple operating modes for best instrument usability.
-
product
Silicon Oscillators
Analog Devices silicon oscillators are frequency programmable via pin-strapping, or through the resistor connection or serial interface (SPI or I2C). These solid-state clocks are well-suited for general-purpose usage, such as PGAs, ASICS, microprocessors, or UARTS, and they operate from 1 kHz to 170 MHz. Silicon oscillators are also ideal switching regulator clocks as they provide synchronization and EMI reduction (via spread spectrum).
-
product
Electromagnetic Immunity Scanner
SmartScan 350
Reproducing similar soft or hard failure to the gun test - Flexible automatic failure detection module - Susceptibility map generation- Automatic report generation- Flexible scan area editor (SAE)- Flexible display (3D, histogram)- Matlab support- Expandability (EMI scan, phase measurement, NFFF transformation)- Custom design probes
-
product
Electromagnetic Interference Analysis Program
EMI Analyst™
EMI Analyst (U.S. Patent # 7,222,033) is the premier tool for ascertaining compliance with EMI requirements imposed by regulatory agencies.EMI Analyst is an electromagnetic interference analysis program that combines all four facets of EMI analysis into a single design package.
-
product
ITA, i2 MX, EMI, High Speed
410130116
This i2 MX ITA includes VTAC rail inserts offering 22 slots for SIM inserts and a maximum of 176 contact positions. Includes front protective cover. Mates with high speed i2 MX receiver p/n 310130113.Cable bundle too large? Choose the i2 XL! XL-Sized backshell, bend radius, & cable exit to better accommodate larger cables such as high-power or high-speed cables.
-
product
Phase Noise Measurement Application
N9068A
One-button measurements for analyzing phase noise in frequency domain (log plot) and time domain (spot frequency)Compatible with phase noise measurement personality in Keysight PSA and ESA spectrum analyzers Runs inside the PXA, MXA, EXA signal analyzers and MXE EMI receiver
-
product
Current Caliper
KH23101
Beijing KeHuan Century EMC Technology Co,.LTD
The KH23101 current caliper is a toroidal transformer used to measure EMI current. When measuring, the caliper does not directly touch the electrical conductor or the cable under test. The conductor passing through the caliper window is used as the single-turn primary wire of the transformer, and the secondary is designed to be multi-turn. Use with 50 Ω receiving system (such as EMI electromagnetic interference field strength meter or spectrum analyzer). In order to facilitate installation and rapid measurement of EMI current, it is designed as a caliper that can be opened.
-
product
Microwave Delay Line
E501
The Eastern OptX Series E501 / Microwave Delay Line is a high performance turnkey solution for radar and communications market. The E501 allows for ultra wide bandwidth, low loss, high isolation and immunity from EMI and EMP with timedelays up to 250 usec at frequencies up to 18 GHz.
-
product
Custom Cable Assemblies
AMETEK Power Instruments has designed and manufactured electrical, thermocouple, and fiber optic harness assemblies for more than sixty years. We have the experience and capability to produce rigid and flexible harness assemblies for virtually any application, whether it is a missile ignition assembly, aircraft actuator assembly or a thermocouple harness for an industrial gas turbine. AMETEK Cable & Harness Products boast superior reliability, high temperature operation, numerous braiding options for abrasion resistance and EMI shielding, waterproof or environmentally sealed, and custom molding. For more information, please contact us.
-
product
Electromagnetic Interference Test
Electromagnetic interference (also known as radio frequency interference) tests are used to determine the electromagnetic characteristics of electrical, electronic, and electro-mechanical equipment. Electromagnetic interference, both radiated or conducted, can affect the performance of equipment. Electromagnetic interference tests are specified as follows: conducted emission, radiated emission, conducted susceptibility, and radiated susceptibility.
-
product
Three-Phase AC Solid-State Relays for Medium Power Applications
Series C3P
The Series C3P three-phase AC solid-state relays are designed to control medium amounts of power in three-phase applications. Optical isolation ensures complete protection of the C3P’s control circuit from load transients. The C3P’s compact plastic housing provides a low-cost alternative to large metallic three-phase contactors. The C3P is designed with heatsinking in mind. The ceramic baseplate provides excellent thermal performance. The relay’s tight zero-cross window greatly reduces EMI.Available options include:C3P24D25 25A, 280 VacC3P24D25C 25A, 280 Vac
-
product
EMI Products
Sophisticated design, manufacture and assembly facilities at Oxley UK production center, include a ceramic production capability for discoidal, tubular, and multiway planar array capacitors, CNC machining, electro-plating, prototype model shop, tool room and dedicated test area.
-
product
ITA, G6, 6 Module, EMI
410104288
This G6 ITA is equipped with a removable EMI-shielded backshell which slides up to provide access to wires and connectors. This ITA also includes a keying feature and has 2 cable bundle exits with a diameter of 1.38" each and provides EMI protection.
-
product
Handheld Power & Energy Meter
Nova 7Z01500
*Compatible with all standard Ophir Thermopile, Pyroelectric & Photodiode sensors.*Single shot energy measurement with thermal sensors.*Optional RS232 computer interface. Works with Ophir's StarCom32 application.*Power and energy logging with graphical display and statistics.*Laser Power Measurement averaging.*Easy to use soft keys, menu driven.*Screen graphics.*Backlight & rechargeable battery.*Analog output.*EMI rejection.*LabVIEW software included.
-
product
EMI Receiver
KH3939
Beijing KeHuan Century EMC Technology Co,.LTD
KH3939 type EMI test receiver interference test receiver is fully automatic, is EMI major tool for testing. The frequency range of the KH3939 receiver is from 9kHz to 300MHz , which satisfies the power line disturbance power test. After configuring the artificial power network, the power terminal disturbance voltage test can be carried out. The machine has fast test speed, strong maneuverability, stable performance, Advantages such as convenient test data processing. The KH3939 receiver uses a U...show more -
product
Human Exposure Measurements to Luminaries
Through different ways of coupling between luminaries and humans, a level of exposure of a person to electromagnetic fields can be derived. One part of the exposure is based on capacitive coupling between lighting equipment and person. This creates induced internal electric field that must be evaluated using an EMI receiver and a Van Der Hoofden test head.